Search Results for dc meter
Direct Current (DC) Monitor - Gemeco
Maretron’s DCM100 DC Monitor is an advanced electronic monitoring device used to measure the voltage and current of any direct current (DC) power source or load. Examples of DC power sources that can be monitored with the DCM100 include batteries, alternators, solar panels, and wind generators.
Model 482A21 | PCB Piezotronics
Model 482A21:1-channel, line-powered, ICP® sensor signal cond., unity gain, BNC input/output conn.
Meter Interface with Seals - Gemeco
The Meter Interface (MI) accepts inputs from external AC and DC power metering sensors such as: AC and DC voltage and amps, AC kWatts, and DC battery capacity in amp hours and percent remaining. All with user definable high and low alarms.
Troubleshooting accelerometer installations - Wilcoxon Sensing Technologies
Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most commonly occurring problems. The troubleshooting techniques presented are very simple and can be performed using most monitoring systems and data collectors or simple test equipment.
PCD200 series dual-input process display panel meters
The PCD200 series are 1/8 DIN digital panel meters that accept two inputs of either a process current (4-20 mA) or process voltage (0-5V, 1-5V, ±10V). It displays these signals on a dual line, 6-digit process display that is available with an optional Sunbright ® sunlight readable LEDs.
Precision Battery Monitor BMV-700 - gemeco.com
This Victron Battery Monitor keeps track of current flowing in and out of a battery bank and uses a sophisticated algorithm to read out the state of charge of the battery in Percentage Remaining and Amp Hours Remaining.
Power Supply and ICP Signal Conditioners - PCB
Prepolarized power supplies and ICP signal conditioners for microphones.
Model 482C15 | PCB Piezotronics
DC Power: 0.25 Amps. Specification Notes [1] Jumper selectable on internal circuit board. [2] The low frequency tolerance is accurate within ±25% of the specified frequency. ... Fault/Bias Monitor/Meter (LED) Open/Short/Overload: Open/Short/Overload: Environmental: Temperature Range (Operating) +32 to +120 °F: 0 to +50 °C: Electrical:
distributors | Amphenol Global Search | Amphenol
Our DC-DC power converters feature wide range of output power from 50W up to 2000W. Output voltage range comes in standard ranges including 5V, 12V, 15V, 24V, 28V, 48V. Custom ranges are also available. Features include high efficiency, low THO, high power factor, internal EMI filters and more.
CZone | Volts/Amps/Circuits - gemeco.com
Meter Interface with Seals. Part # 80-911-0005-00. MFG # 80-911-0005-00. ... DC Current Shunt. Part # LB-450-50. MFG # LB-450-50. Exterior Color. Black. Comm Method.
Dual-input process meters - Wilcoxon Sensing Technologies
• Dual input process meter with math functions • 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ± 10 V inputs • SunBright display models for outdoor applications • NEMA 4X, IP65 front panel • Input power options include 85-265 VAC or 12-24 VDC • 2 or 4 relays + isolated 4-20 mA output options • Includes PC-based programming and monitoring ...
N2K Diagnostics Meter - Gemeco
The N2KMeter is a diagnostic tool for NMEA 2000® networks that allows users to validate NMEA 2000® network compatibility and operations during installation of a device or complete system, and diagnose possible network flaws or failures that occur on an operational network.
Model 482C05 | PCB Piezotronics
Model 482C05:Platinum Stock Products; 4-channel, line-powered, ICP® sensor signal cond., unity gain, BNC input/output conn.
Mini Cordsets - TPC Wire
TPC's Mini Quick-Connex® cordset and receptacle assemblies and accessories offer the best in miniature connectors. Our sealed mini connectors are designed to withstand and operate effectively in an industrial environment and are easy to install and maintain.
Troubleshooting Using Bias Voltage | PCB Piezotronics
Unlike an operational amplifier (Op Amp) that requires a plus and minus supply and allows the signal to "ride" on ground and "swing" between the plus and minus "rails," the ICP® sensor requires the output signal to be DC biased. This DC bias voltage is an excellent diagnostic tool.
Fluid Flow Monitor - gemeco.com
Maretron's FFM100 provides precision fuel flow information to help optimize fuel consumption, which can save thousands of dollars in fuel operating cost. The FFM100 uses state-of-the-art, positive displacement metering technology for unprecedented accuracy.
Introduction to MEMS Accelerometers | PCB Piezotronics
Unlike ICP® sensors, MEMS sensors measure frequencies down to 0 Hz (static or DC acceleration). PCB® manufactures two types of MEMS accelerometers: variable capacitive and piezoresistive.
Troubleshooting accelerometer installations - Wilcoxon Sensing Technologies
Most accelerometer faults can be diagnosed by measuring the bias voltage of the sensor amplifier. If the bias voltage is within correct limits the sensor is most likely operating properly. Most cabling faults can also be isolated by measuring the bias.
Variable Capacitance MEMS Accelerometers | PCB Piezotronics
Variable capacitance MEMS (VC MEMS) accelerometers are DC-response sensors for measuring low frequency vibration, motion (constant acceleration) and tilt. Micro-Electro-Mechanical Systems (MEMS) technology is the backbone of VC accelerometers.
Triaxial low g DC accelerometer - pcb.com
The ENDEVCO® Model 773 is a triaxial low g DC accelerometer that utilizes unique variable capacitance microsensors.