Search Results for 110 block connector
Product Data Sheet - Temposonics
MTS Sensors R-Series Models RP and RH Temposonics® Linear-Position Sensors - Profinet Industrial Profinet Interface Product Data Sheet, Part No.: 551451, Revision A 08/13 6 Sensor mounting Model RP profile-style sensor mounting flexible installation in any position! Temposonics Model RP profile-style sensors offer two basic mounting methods; side grooves for use with mounting feet or a bottom ...
BD550W Series Dehydrators - Max - RFS Technologies
RADIAFLEX Connectors & Accessories Field Installable Connectors Installation Accessories. ... Indoor RF Components Power Splitter Directional Coupler Hybrid Combiner Tapper Termination Load DC Block. Product Cross-Reference. Solutions. Indoor Solutions; Macro Site Solutions ... 110 - 125 VAC, 50 / 60Hz (15 Amp service recommended) 208 - 253 VAC ...
SMA to BNC Adapters - RF Coaxial Adapters - Amphenol RF
SMA to BNC Adapters feature all industry standard connector interfaces in between-series and in-series designs. Shop Categories Search. Products. Back; RF Connectors. Back; Featured Category. RF Connectors; 1.0-2.3 Connectors; 1.6-5.6 Connectors; 2.2-5 Connectors; 2.92 mm Connectors; 4.1-9.5 Connectors; 4.3-10 Connectors; 7-16 Connectors; AFI ...
Cross Reference - Airmar
AIRMAR provides information in this cross-reference as a guideline for choosing the correct transducer for your specific fishfinder. Our OEM customers frequently change their models, software versions and plug configuration, which may not be reflected in this cross-reference guide.
MIL-DTL-5015, Matrix - Amphenol Aerospace
connector stan dard and the environmental and high perfor - mance needs of current technologies. DESIGN CHARACTERISTICS • Medium to heavy weight enviornmental cylindrical • MS345( ) series intermateable with existing MIL-DTL-5015 solder or crimp versions on existing equipment • Captive coupling nut mechanism, utilizes retaining rings
SYSTEM ATTACHMENTS - amphenolpcd.com
Visit amphenolpcd.com for more information 3 INDEX ALBPCL75P High Performance P-Clamps High Performance Omega Clamps High Performance LDG P-Clamps Light Weight C-Clamps (CC1339L) C-Clamps 5516
Understanding Different Cable Gland Thread Types: NPT, Metric, & PG
Cable glands are an essential component of any electrical installation, and understanding the different types of thread used in cable glands is important. The three most common types of threads used in cable glands are NPT, Metric, and PG. Understanding the differences between these thread types will help you choose the right cable gland for your needs.
1750 Distribution Modules - Amphenol-Air LB
Customer Service 2 rue Clément ADER, Zac de Wé 08110 Carignan FRANCE Tel : +33 (0)3 24 22 32 66 Fax : +33 (0)3 24 22 38 72 customer-service@amphenol-airlb.fr
amphenol bursa | Amphenol Global Search | Amphenol
For additional information on Amphenol® 97 Series connectors, or for special application requirements, contact your local Amphenol sales office, authorized distributor, or - Amphenol Corporation Amphenol Industrial Operations 40-60 Delaware Avenue Sidney, New York 13838-1395 Telephone: 607-563-5011 Fax: 607-563-5157 Web site: www.amphenol ...
Data Sheet R-Series V RP5 Profinet 551961 - Temposonics
Connection type 2 × M12 female connectors (D-coded), 1 × M12 male connector (A-coded) 2 × M12 female connectors (D-coded), 1 × M8 male connector Operating voltage +12…30 VDC ±20 % (9.6…36 VDC) Power consumption Less than 4 W typical Dielectric strength 500 VDC (DC ground to machine ground) Polarity protection Up to −36 VDC
IP67 D-SUB Connectors - CONEC
Industrial use in harsh environments requires connector systems that meet special requirements. Whether in traffic control systems, photovoltaic systems, construction machinery, surveillance cameras or off-shore wind farms, modern industrial applications place high demands on the connectors used. IP67 D-SUB connectors are used where dust and ...
Accelerometers / Vibration Sensors | PCB Piezotronics
PCB ® manufactures sensors used by design engineers and predictive maintenance professionals to test and measure vibration, pressure, force, acoustics, load, and shock in research and development as well as industrial applications.. Divisions of PCB
KAYE Global Contacts
KAYE HEADQUARTERS. Amphenol Advanced Sensors Germany GmbH Sinsheimer Strasse 6 D-75179 Pforzheim. T +49 (0) 7231-14 335 0 F +49 (0) 7231-14335 29 kaye-ccpf@amphenol-sensors.com
amphe-power-radsok-technology-catalog-amphenol-industrial
Amphe-Power Connectors with RADSOK Technology SL-391-4 ® ® † Socket cylinder within female contact has several equally spaced longitudinal beams twisted into a hyperbolic shape. † As male pin is inserted, axial members in the female half deflect, imparting high current flow across the connection with minimal voltage loss.
Amphenol Connectors | Cable Assemblies | Interconnects | Mobile, RF, Optics
Amphenol Connectors | Cable Assemblies | Interconnects | Mobile, RF, Optics
English - Amphenol CS
This site is best viewed on Google Chrome or Firefox or Safari or Edge. Terms of Use; Privacy Policy
CEMM THOME, spol. s.r.o.
Sockets, Grommets & Connectors. Sealed sockets for P21W, P21W, W5W, W16W bulbs Unsealed sockets for P21W bulbs Sealed & unsealed bulb sockets for H7 & H1 bulbs. our applications. Lightings. Dash Board Lighting Int. LED Lighting Head Lighting Ext. LED Systems Door Panel Lighting Rear Lighting CHMSL
International Distributors | PCB Piezotronics
3425 Walden Avenue Depew, NY 14043. Sensorline SM 716.684.0001. info@pcb.com +1 800-828-8840
What’s the Difference Between 50 Ohm and 75 Ohm Coaxial Cable?
The Impedance of the various devices being connected as well as the Coaxial Cable itself must match. So if you are, for instance, connecting a 75 Ohm video camera connection to a studio monitor, the coaxial cable must also be 75 Ohm AND the connectors on the coaxial cable (i.e. BNC connectors) must be 75 Ohm in Impedance.