Search Results for 162
NovaSensor P165 3F Medical Silicon Absolute Pressure Sensor Die
P162 Specifications Performance Parameters(1) Value(4) Units Notes Pressure Range -50 to 300 mmHg Gage Operating Temperature 50 to 122 °F (10°C to 50°C) Excitation 1 to 8 Volts AC or DC
World class antenna solutions for Hazardous environments - AMPHENOL PROCOM
5 CXL 130-1C-Ex ATEX certified, 0 dBd, Omnidirectional Base Station Antenna for the International Aircraft Band. Frequency range 110-140 MHz Gain: 2 dBi 0 dBd
Airmar Technology | Temperature
Airmar Technology Airmar Technology's temperature transducers are a game-changer for anyone looking to accurately measure temperature in a variety of applications. Their high-quality, durable transducers are designed to withstand harsh environments and provide precise readings with a high degree of accuracy. With models available in a range of configurations, including waterproof and explosion ...
Prepolarized 1/2" Microphones - PCB
PCB ® manufactures sensors used by design engineers and predictive maintenance professionals to test and measure vibration, pressure, force, acoustics, load, and shock in research and development as well as industrial applications.. Divisions of PCB
D38999 Series III Hermetic Connectors - Amphenol Aerospace
Amphenol Tri-Start MIL-DTL-38999 Series III Hermetic Connectors offer the highest performance capabilities for both general duty and severe environment applications and meet or exceed MIL-DTL-38999 Series III requirements.
Marine Antennas MA 160-Ex - AMPHENOL PROCOM
Models within 154 - 162.025 MHz. Full-size, end-fed ½ λ, black-chromed stainless steel whip. Before installing the antenna, read the ATEX Product Manual carefully. The antenna is suitable for use in gas groups IIA, IIB and IIC in zone 2. The antenna can be mounted on threaded 1" water pipe using the supplied 1" revolving nut.
Model 685A08 | PCB Piezotronics
Mechanical vibration switch with CSA and UL approvals, 0 to 7 G's pk, 0 to 100 Hz. Mechanical vibration switch, 0- 7 g pk, 0-6000 cpm, latching relay, single form C electromechanical relay, pushbutton reset, NEMA 7 Explosionproof Class 1 Div 1 gps C & D, 1/2-14 NPT connection interface
TEMP | Amphenol Global Search | Amphenol
Our high temperature ICP® accelerometers with internal electronics have the best temperature capability of any comparable design on the market today, with continuous operating temperatures of up to 325 °F (162 °C).
Absolute, Non-Contact Position Sensors Data Sheet C ... - Temposonics
Technical Data Input Measured variables: Position Stroke length: 72, 109, 128, 148, 162, 186, 194, 217, 250 mm Output Analog: 0.1 - 4.9 VDC
Temposonics
Document Part Number: 552085 Revision A (EN) 01/2021 Sensor Nu one 36.1 16.7 23 Stroe ength 72…275 Dea one 22.7 4 Position magnet 9 Sensor assembled with pressure pipe E2
C091 31D107 101 2 - M16 Female cable connector with internal
Female cable connector with internal strain relief and metal locking ring. 7 contacts, silver plated, 6-8mm cable diameter, B arrangement. Complete EMI shielding in the fully mated and locked position (EMI security).
TNC to FME Adapters - RF Coaxial Adapters - Amphenol RF
Amphenol RF offers a full range of TNC to FME Adapters designed for radio frequency applications. TNC to FME Adapters feature all industry standard connector interfaces in between-series and in-series designs.
FME Adapters - RF Coaxial Adapters - Amphenol RF
Amphenol RF offers a full range of FME Adapters designed for radio frequency applications. FME Adapters feature all industry standard connector interfaces in between-series and in-series designs.
Intrinsically Safe vibration transmitter, velocity, peak, 1.0 in/sec
Intrinsically safe vibration transmitter, 4-20 mA output proportional to peak velocity vibration, 1.0 in/sec full-scale measurement range, ±5% tolerance at full scale, operates up to 85°C, top exit 2-pin MIL-C-5015 style connector, certified for use in Class I Division 1 and Zone 0 / Zone 1 hazardous locations
FAKRA Straight Plug to SMA Straight Plug RG-174 50 Ohm 24 inches Z Key ...
FAKRA Straight Plug to SMA Straight Plug RG-174 50 Ohm 24 inches Z Key Code (610 mm)
HT200 Smart™, Hi-Precision Temperature Sensor, Plastic ... - Gemeco
HT200 Smart™, Hi-Precision Temperature Sensor, Plastic Housing, Thru Hull, NMEA 2000®
PAPER MACHINES & CONVEYORS
Ideal for high temp applications to 325 ºF (162 ºC) n. Hermetically sealed with integral FEP jacketed cable (optional armor jacket) n. Low profile design eliminates concerns about cable bend radius. IECEx IECEx. IECEx IECEx. 3.
GT Series Reverse Bayonet Coupling Connectors
3 front face of pin insert or rear face of socket insert illustrated GT Series for Bombardier contact arrangements Insert Arrangement 10SL-3 14S-6 16S-1 16-10 18-1 Service Rating A Inst. A A B, C, F, G = A; Bal. = Inst.
GTE Analog Data sheet - Temposonics
2 Temposonics® TE Analog ATE EC CEC Data Sheet 5 3 1 2 4 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (waveguide)
ICP® PRESSURE SENSOR - PCB
Model Number 105C22 ICP® PRESSURE SENSOR Revision: H ECN #: 55250 Performance ENGLISH SI Measurement Range(for ±5V output) 5,000 psi 34,475 kPa Sensitivity(± 15 %) 1.0 mV/psi 0.145 mV/kPa