Search Results for 20 27b
High Sensitivity ICP® Accelerometers | PCB Piezotronics
4-20 mA Transmitters. Vibration Transmitters; Reciprocating Machinery Protector; DIN-Rail Mount Module; Displays & Alarms; Bearing Condition Monitors; Hazardous Area Approved; Embeddable OEM Pellets; Vibration Switches. USB Smart Switches; Electronic Switches; Mechanical Switches; Pressure Transducers. ICP® (Up to 250 F) Charge (Up to 1200 F ...
Data Sheet MH-Series MH Threaded Analog - Temposonics
20 g (r.m.s.) Ø 10 mm rod (10…2000 Hz) - resonance frequencies excluded EMC test 2009/64/EG Road vehicles 2009/19/EG Agricultural and Forest machines ISO 14982 Emissions/Immunity ISO 7637-1/2 Transient Impulses ISO / TR 10605 Electrostatic Discharge (E.S.D.) Pressure impulse test according DIN EN ISO 19879Ø 7 mm rod Ø 10 mm rod Operation ...
Connector Solutions M23 Standard Series - Amphenol Sine
Figure 20 MB4FSR-B10.3 MB4FSR-B12.5 MB4FSR-B14.5 MB4FSR-B17.0 Cord Grips MB6CG-S1 MB6CG-S2 MB6CG-S3 Figure 19 6 POSITIONS 28A / 630V Number of Contacts: 6 Contact Size: 2.0mm Sealing: IP66/67 AWG: 18-14 (0.75 - 2.5 mm2) Complete datasheets can be found at www.amphenol-sine.com Threaded Dimensions 90º Rotatable Receptacles / Dimensions Cord
Data Sheet R-Series RP PROFIBUS - Temposonics
Measured value Position/option: Simultanous multi-position measurement with up to 20 magnets Accuracy Resolution Position 1…1000 µm (selectable) Cycle time Stroke length ≤ 500 mm 2000 mm 4500 mm 5080 mm Cycle time 0.5 ms 1.0 ms 2.0 ms 3.1 ms (each additional magnet + 0.05 ms)
Scala2 User Manual - Marport
V1 02/11/20 First release, documents Scala2 version 02.00.00. V2 07/16/20 Documents Scala2 version 02.02. New topics • Using the MultiTrawl View on page 67: Multitrawl view: now compatible with quad trawls • Adding Events on page 100: Event markers can be added in live time, then found back when replaying data on ScalaReplay2
Ø21.8 - Amphenol Sine
B2 MODIFY THE INSERT LETTER LOCATION MAY-20-2016 BEN TOMMY B3 UPDATE RATED VOLTAGE NOV-11-2022 JUN TOMMY. ecomate® RM/RSSM/Aquarius™ - Contact Size 20 Options Amphenol Sine Systems 44724 Morley Drive, Clinton Township, MI 48036 USA www.amphenol-sine.com 09/2021 Machined, Crimp Contacts
IECEx - PCB
JJF 10/8/20 JJF 10/8/20 YHK 10/8/20. 5. PCB Piezotronics Inc. claims proprietary rights in the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others without the written consent of PCB Piezotronics Inc. REVISIONS. REV DESCRIPTION DIN. A REMOVED CABLE 51169.25 [6.4] CUBE .39 [9.9] "Z" "X" "Y"
Amphenol® /Matrix® MIL-C-26482, Series 2 Connectors
• Accommodation of contact sizes 20, 16 and 12 • 34 insert arrangement patterns available, accommodating from a minimum of 3 to a maximum of 55 circuits • Alternate positioning available • Various finishes are available (for information on non-cad-
Operation Manual Level Plus Interface Manual HART - Temposonics
5.Move the float towards the top of the pipe and verify 20 mA set point. 6.If using two floats, repeat steps 4 and 5 for second float. Test pins for Loop 2 are TP5 and TP6. Note both floats must be present or else the level transmitter will go into alarm. 7.Turn off power and disconnect power supply and current meter. 8.Install in tank. 6 ...
36.5 - Amphenol Sine
14 - 20 AWG 3.68 mm (.145 in) 44724 Morley Drive Clinton Township, MI 48036 Sine Systems - www.amphenol-sine.com Amphenol MATERIALS LIST SIZE PROCESS SPECIFICATIONS: MATERIAL SPECIFICATIONS: UNLESS OTHERWISE SPECIFIED 3 PL DEC ±0.08 1) All dimensions are in metric(mm). 2) Tolerances are as follows: 1 PL DEC ±0.30
Introduction to Dynamic Pressure Sensors - PCB
It is generally acceptable to use sensors over a range where the sensitivity deviates by less than ± 5%. The upper frequency limit occurs at approximately 20% of the sensor resonant frequency. The high frequency response can be limited by drive current, cable length and cable capacitance.
Internally amplified helicopter accelerometer
–20% +10% Power requirement: Voltage source 9 VDC, 700 µA, max. Electrical noise, equiv. g, nominal: Broadband 2.5 Hz to 25 kHz Spectral 10 Hz 100 Hz 1,000 Hz 70 µg 5.0 µg/√Hz 0.8 µg/√Hz 0.5 µg/√Hz Output impedance 100 Ω Bias output voltage, nominal 4.2 ± 0.5 VDC
Product Page | PCB Piezotronics
PCB ® manufactures sensors used by design engineers and predictive maintenance professionals to test and measure vibration, pressure, force, acoustics, load, and shock in research and development as well as industrial applications.. Divisions of PCB
IECEx - PCB
20 mA of constant current. PCB’s offering of single axis and triaxial piezoelectric accelerometers include measurement ranges from as low as 0.5 g up to 100,000 g. IECEx IECEx IECEx IECEx TYPICAL APPLICATIONS n. Environmental Stress Screening (ESS) n Electronic board testing n Mobile electronics drop testing n Small component shock testing
PS SERIES PSMATPLDCU140P500-X - Amphenol Socapex
Procedure II – up to 20 000 ft. Humidity IAW MIL -STD 810G Method 507. 5 Up to 95%. Fungus IAW MIL -STD-810G Method 508.6 Sand and Dust IAW MIL -STD-810G Method 510.5 Procedure I Shock IAW MIL -STD-810G Method 516.6 Procedure I, Figure 516.6 -10 20 g, 11 ms terminal peak saw-tooth (all directions)
IECEx - PCB
1 800 828 8840 | pcb.com. MODELS . 352A71, 352A72, 352A73 & 352A74. TEARDROP ICP ® ACCELEROMETERS . WITH FLEXIBLE, INTEGRAL CABLE n Very small teardrop-shape n Flexible integral cable for easy routing in tight spaces
ICP® PRESSURE SENSOR - PCB
Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance < 100 Ohm < 100 Ohm Output Bias Voltage 8 to 14 VDC 8 to 14 VDC Electrical Isolation 108 Ohm 108 Ohm Physical Sensing Geometry Compression Compression Sensing Element Quartz Quartz Housing Material Stainless Steel Stainless Steel
ICP® PRESSURE SENSOR - pcb.com
Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance < 100 Ohm < 100 Ohm Output Bias Voltage 8 to 14 VDC 8 to 14 VDC Electrical Isolation 108 Ohm 108 Ohm Physical Sensing Geometry Compression Compression Sensing Element Quartz Quartz Housing Material Stainless Steel Stainless Steel
PRESSURE FUNDAMENTALS - PCB
16 channels with current adjustment within 2 to 20 mA at +18 to +30 volts DC. Refer to PCB Tech NoteTN-32 for more information on signal conditioners and impedance. Do not attempt to power ICP ® sensors with commercially . available power supplies as unregulated current will damage the sensors' internal electronics.