Search Results for 20 27b
0.50mm Pitch FFC/FPC - F31L Series - Amphenol CS
www.mhe-cs.cm Disclaimer Pese te tht the ve irmti is sect t che itht tice. 0.50mm Pitch FFC/FPC - F31L Series MATERIAL § Housing: LCP, Natural color (UL94V-0) § Actuator: PA9T, Black color (UL94V-0 § Contact: Phosphor bronze, T=0.20mm, 1~3µm Ni under plating § Anchor-plate: Brass, T=0.20mm, 1~3µm Ni under plating, 2~4µm tin plating
Model 137B23A ICP® Pressure Sensor Installation and Operating Manual - PCB
1, 20, 10 and 100 mV/psi with full-scale ranges from 0 to 50, 250, 500 or 5000 psi. The 137B2XX Series is constructed with a stable quartz piezoelectric element in an Invar housing 2.0 INSTALLATION In field blast measurements, mount the Series 137B2XX pressure probe in an axial direction to the blast source.
B A5 - Amphenol Sine
A Series™ - Contact Size 16 Options (Works with: AT, ATV, AHD-9, ARC, DuraMate and PanelMate Series) Amphenol Sine Systems 44724 Morley Drive, Clinton Township, MI 48036 USA www.amphenol-sine.com 10-2023 Machined Contacts, Sockets & Pins Part Number DescriptionSize AWG Type
Model 137A21 ICP® Pressure Sensor Installation and Operating Manual
the higher current, up to 20 mA maximum. Use of low-capacitance cable (i.e. RG 62/U) and impedance-matching variable resistors are suggested to improve long cable performance characteristics at high frequencies. 3.1 POLARITY The 137A20 Series produces a positive-going output voltage for increasing pressure output. 4.0 LOW-FREQUENCY RESPONSE
IECEx - PCB
20 mA of constant current. PCB’s offering of single axis and triaxial piezoelectric accelerometers include measurement ranges from as low as 0.5 g up to 100,000 g. IECEx IECEx IECEx IECEx TYPICAL APPLICATIONS n. Environmental Stress Screening (ESS) n Electronic board testing n Mobile electronics drop testing n Small component shock testing
PCB Piezotronics | Measure vibration, pressure, force, and more
PCB Piezotronics | Measure vibration, pressure, force, and more
Temposonics
Current 4(0)…20 mA and/or 20…4(0) mA (minimum/maximum load: 0/500 Ω) Measured value Position Measurement parameters Resolution 16 bit (minimum 1 μm depending on stroke length) 1 Cycle time Stroke length ≤ 1200 mm ≤ 2400 mm ≤ 3000 mm Cycle time 0.5 ms 1.0 ms 2.0 ms Linearity2 ≤ ±0.02 % F.S. (minimum ±60 μm)
PRESSURE FUNDAMENTALS - PCB
16 channels with current adjustment within 2 to 20 mA at +18 to +30 volts DC. Refer to PCB Tech NoteTN-32 for more information on signal conditioners and impedance. Do not attempt to power ICP ® sensors with commercially . available power supplies as unregulated current will damage the sensors' internal electronics.
アンフェノールジャパン株式会社
Science & Technology Connector test results and ratings in brief CN30-D020 PV - KBT 3 (configurable) PV - KB T 3 (preconfigured) Y-S013AOV-F Helios H4, H4CMC4D / PV-100508-F
Data Sheet MH-Series MH Threaded Analog - Temposonics
20 g (r.m.s.) Ø 10 mm rod (10…2000 Hz) - resonance frequencies excluded EMC test 2009/64/EG Road vehicles 2009/19/EG Agricultural and Forest machines ISO 14982 Emissions/Immunity ISO 7637-1/2 Transient Impulses ISO / TR 10605 Electrostatic Discharge (E.S.D.) Pressure impulse test according DIN EN ISO 19879Ø 7 mm rod Ø 10 mm rod Operation ...
How to Buy - Airmar
Discover the easy process of purchasing Airmar's marine sensing technology. Buy our transducers, sensors, and smart solutions through our authorized distributors and resellers. Access high-performance marine sensing equipment for your applications with Airmar's convenient and reliable purchasing process.
36.5 - Amphenol Sine
14 - 20 AWG 3.68 mm (.145 in) 44724 Morley Drive Clinton Township, MI 48036 Sine Systems - www.amphenol-sine.com Amphenol MATERIALS LIST SIZE PROCESS SPECIFICATIONS: MATERIAL SPECIFICATIONS: UNLESS OTHERWISE SPECIFIED 3 PL DEC ±0.08 1) All dimensions are in metric(mm). 2) Tolerances are as follows: 1 PL DEC ±0.30
MINIATURE ACCELEROMETERS - PCB
2-20 mA. Output Impedance; ≤ 200 Ohm. Output Bias Voltage; 8 to 12 VDC. Discharge Time Constant; 0.8 to 2.4 sec. Settling Time (within 10% of bias) ≤ 5 sec. Spectral Noise (1 Hz) 300 µg/√Hz. 2943 (µm/s; 2)/√Hz 300 µg/√Hz. 2943 (µm/s; 2)/√Hz 300 µg/√Hz. 2943 (µm/s; 2)/√Hz Spectral Noise (10 Hz) 50 µg/√Hz; 491 (µm/s. 2 ...
PROTIMETER Timbermaster - amphenol-sensors.com
wood at 20°C (70°F). In general, tim-ber that is hotter than 20°C will give higher readings and timber colder than 20°C will give lower readings. An approximate manual correction of 0.5% moisture content per 5°C may be subtracted from timber that is above 20°C. For timber that is below 20°C, a manual correction of 0.5%
ZTP-115M Thermopile IR Sensor - amphenol-sensors.com
Outline of Sensor Packaging and Pin Arrangement Temperature Accuracy (Typical)-4-3-2-1 0 1 2 3 4 Te m pe r a t u r e D e v i a t i on ℃ O bject Tem p. : 60℃ 0 20 ...
Mounting hardware and accessories - Wilcoxon Sensing Technologies
20 lbf 20 lbf 35 lbf 55 lbf 130 lbf Diameter 0.81 in 0.75 in 1.00 in 1.25 in 2.00 in Height 0.56 in 0.76 in0.78 in 1.10 in Thread 8-32 1/4-28 Note: All M-series magnets are non-isolated. Temporary mounting solutions [email protected] buy.wilcoxon.com wilcoxon.com. Specialty mounting Fin mounts The FM series is designed to be epoxied or welded ...
Charles Industries, LLC
National Standards Authority oflreland Inc., 20 Trafalgar Square, Nashua, New Hampshire, 9001 (2. I ) I of2 NH 03063, USA T +1 603 882 4412 . NSAI Annex to Certificate Number: 19.4427 Scope of Registration: The design, manufacture and sale of telecommunications, CATV and industrial products Activity
Amphenol Industrial Operations
We would like to show you a description here but the site won’t allow us.
Signal Conditioning Basics | PCB Piezotronics
All PCB line-powered signal conditioners use higher capacity (up to 20 mA) constant current circuits in place of the diodes, but the principle of operation is identical. Decoupling of the data signal occurs at the output stage of the signal conditioner. The 10 to 30 µF capacitor shifts the signal level to essentially eliminate the sensor bias ...