Search Results for 20-33
Thermometrics Glass-Encapsulated Chip (GC) Thermistor
Title: Thermometrics Glass-Encapsulated Chip (GC) Thermistor Author: Amphenol Advanced Sensors Subject: Glass-encapsulated Chip (GC) Thermistors are very small glass-encapsulated thermistors.
High Voltage Safety Lock - Amphenol Australia
20 name Contact P/n & Wire Size Drawing 1 Pin Box mounted receptacle for Inter-Lock C42000400504G 0.5mm2 max wire 2 or 3 pin for Inter-Lock C20003609 0.5mm2 max wire Power contact
Model 480B21 | PCB Piezotronics
Model 480B21:3-channel, battery-powered, ICP® sensor signal cond., gain x1, x10, x100, BNC input/output conn.
B175 High Wide Chirp, 1kW, 20° Tilt, Garmin 8-Pin, DT
Marine Transducers. Chirp-Ready Transducers; NMEA/SMART Transducers; Traditional Frequency Transducers; Speed & Temperature; Multi-Beam Transducers; Transducer Diagnostic Tester
SS75 High Chirp, 600W, 20° Tilt, Furuno 10-Pin, DT
Tilted Element ™ transducers have the element fixed at a 20°, 12°, or 0° angle within the housing. Because the transducer is installed almost flush to the hull, the tilt corrects for the hull deadrise. It orients the ceramic element horizontally to ensure maximum echo returns to the transducer. ... Cable-Length: 10 m (33') Common Use: ...
G:SharedAmphenol Customer DatasheetsMicro-DNet-ControlpowerMN57AD02
temperature range: -20°c to +105°c protection: ip67 (mated condition) mating cycles: >500 vibration resistance per mil-std-202 method 204 thermal shock per mil-std-202 method 207 48 hour salt spray per mil-std-202 method 101 2) electrical data: ... 1/11/2016 11:33:44 am ...
B75 High Chirp, 600W, 20° Tilt, Raymarine 11-Pin, DT
B75 High Chirp, 600W, 20° Tilt, Raymarine 11-Pin, DT. emea. Skip to main content. Site Search. Search. submit search. menu. Search. Products. Marine Transducers. Chirp-Ready Transducers; NMEA/SMART Transducers; ... +33 (0)2 23 52 06 48 [email protected] 9 Bis Rue De Grand Jardin ZI SUD 35400. Saint Malo, France. TECHNICAL.
550905G M-Series Model MR Sanitary Application data sheet ... - Temposonics
Phone: +33 614 060 728 E-Mail: info.fr@temposonics.com UK Branch Office Phone: +44 79 21 83 05 86 E-Mail: info.uk@temposonics.com SCANDINAVIA Branch Offi ce ... 4 to 20 mA setpoints are set at the ‘Minimum’ or ‘Maximum’ positions unless otherwise specified. ‘Minimum’ is set to 76 mm (3 in.), 97
NTC Type FP07 Thermometrics Fastip Probe Thermistor
M 20 N 25 P 30 Q 40 R 50 S Non-standard (consult factory) FP ___ ____ ____ ____ ____ Typical model number *The zero-power resistance at 77°F (25°C), expressed in ohms (W), is identified by a three digit number. The first two digits represent significant figures and the last digit specifies the number of zeros to follow.
SYSTEM ATTACHMENTS - Amphenol PCD
Visit amphenolpcd.com for more information 3 INDEX ALBPCL75P High Performance P-Clamps High Performance Omega Clamps High Performance LDG P-Clamps Light Weight C-Clamps (CC1339L) C-Clamps 5516
Temposonics
I 6 I Temposonics® EP / EL Analog Data Sheet b Design 0 Without position magnet (order separately) a Sensor model L Ultra low profile P Compact profile d Connection type D 3 4 M12 (5 pin) male connector e Operating voltage 1 +24 VDC (−15 / +20 %) c Stroke length X X X X M 0050…2540 mm X X X. X U 002.0…100.0 in. ORDER CODE f Output
Amphenol Canada Corp.
oct 20,10 oct 19,10 oct 19,10 j.si oct 19,10 4 or used for manufacturing puposes without permission from amphenol canada corp. title 2:1 a 7 description x.x 1xn sfp+ cage elastomeric gasket, with light pipe assembly (under belly spring finger and no half moon emi pins) 33.75 (typ.) 14.00±0.10 28.25 8.95±0.15 (typ.) u77-a241m-x071 p/n: u77 ...
SS175 Medium Chirp, 1kW, 20° Tilt, Navico BL, DT
Airmar’s Tilted Element ™ transducers have the element fixed at a 20°, 12°, or 0° angle within the housing. Because the transducer is installed almost flush to the hull, the tilt corrects for the hull deadrise. It orients the ceramic element horizontally to ensure maximum echo returns to the transducer. ... Cable-Length: 10 m (33 ...
B175 Medium Chirp, 1kW, 20° Tilt, Furuno 12-Pin, DT
Airmar’s Tilted Element ™ transducers have the element fixed at a 20°, 12°, or 0° angle within the housing. Because the transducer is installed almost flush to the hull, the tilt corrects for the hull deadrise. It orients the ceramic element horizontally to ensure maximum echo returns to the transducer. ... Cable-Length: 10 m (33 ...
High Temperature Charge Output Accelerometer - PCB
4-20 mA industrial vibration sensors and transmitters for 24/7 monitoring, electronic and mechanical vibration switches, the patented Bearing Fault Detector, high temperature accelerometers to +1300 °F (+704 °C), 2-wire ... 2/17/2015 8:50:33 AM ...
general motors | Amphenol Global Search | Amphenol
First Quarter 2021 Highlights: Sales of $2.377 billion, up 28% in U.S. dollars and 23% organically 1 compared to the first quarter 2020 GAAP diluted EPS of $0.53, up 33% compared to the prior year period Adjusted Diluted EPS 1 of $0.52, up 49% compared to the prior year period Operating margin of 19.6% Operating Cash Flow of $321 million and ...
TIE WRAP BACKSHELLS - amphenolpcd.com
sjmm)nax ground lug optional cable entry max ground lug optional carle try(max)
CHAMBERED Application Data Sheet - Temposonics
4 mA or 20 mA Setpoint 74 mm (2.9 in.) standard (Circle one) 4 mA or 20 mA Setpoint Order length standard Level Plus 145 mm (5.7 in.) Order length Measuring range (Center to center) 2 ft. 9 6 3 1 ft 9 6 3 0 ... Phone: +33 614 060 728 E-Mail: info.fr@temposonics.com UK Branch Office Phone: +44 79 21 83 05 86 E-Mail: info.uk@temposonics.com ...
Certified accelerometer and charge amplifier system
Frequency response, ± 3 dB 0.5 Hz - 20 kHz 0.5 Hz - 20 kHz Resonance frequency >37.5 kHz >37.5 kHz Transverse sensitivity 3% of axial, max 3% of axial Temperature response: –50°C • Charge output +260°C –10% +20% –10% +20% Capacitance, nominal 1,000 pF - Resistance, min 1,000 MΩ - Power requirement: Voltage source Current regulating ...
Low-frequency accelerometer - Wilcoxon Sensing Technologies
797L-33 797L-35 II 1 G Ex ia IIC T4 Ga Tamb: -50°C to 120°C For Hazardous area installations the transducer must be installed per 11537. The model 797L-35 transducer must not be subjected to an acceleration greater than 1200g and must be mechanically protected so that it is not subjected to impacts greater than 2 J energy. 0.20”