Search Results for 97-3106a-20
Product Specification / Data Sheet - Temposonics
97 mm (3.8 in.) Heat shrink sleeve Figure 1. R-Series Model RF flexible housing dimension reference Standard magnet selections (Model RF) POSITION MaGNeT SeLeCTIONS (Drawing dimensions are for reference only) Magnet and magnet dimensions Description Part number 4 Holes Each 4.3 mm (0.17 in.) dia. 90° apart on 24 mm (0.94 in.) dia. Standard ...
38999 CONNECTORS WITH POWER CONTACTS - Amphenol Aerospace
20 9 5 E C DZ Black Zinc-Nickel alternative to cadmium. Corrosion resistant, 500 hour salt spray, conductive, -65°C to +175°C R o H S A m p hen o l E U / 20 /9 5 C DS AP-93 Tri-Nickel Alloy, Aluminum, 1000 Hr., 200°C, -65dB@100Hz* R o H S A m p hen o l E U / 20 /9 5 C DW Corrosion resistant olive drab cadmium plated aluminum,
Data Sheet E-Series ET Start-Stop 551676 - temposonics.com
Vibration test 20 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies) EMC test Electromagnetic emission according to EN 61000-6-3 Electromagnetic immunity according to EN 61000-6-2 The ET sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 No. 1091 and ... (1.97) Ø 10 ± 0.13 (Ø 0.39 ...
HVMC2P12MV103 | Amphenol Global Search | Amphenol
97-3102a-20 | Amphenol Global Search | Amphenol HVMC2P12MV103 | Amphenol Global Search | Amphenol 97 series | Amphenol Global Search | Amphenol. 348 Series connectors are qualified to MIL-C-81511 and provide reliability and high contact density. View Download. 38999 Catalog Contains information on 38999 Series I, II, and III, as well as SJT ...
Data Sheet R-Series V RFV Analog - Temposonics
2 Temposonics® R-Series V RFV Analog 3 1 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (waveguide) Position magnet (magnetic fi eld)
amphe-lite-subminiature-connectors-catalog-amphenol-industrial
25-7 NA 99 97 2 25-8★ NA 8 8 25-11 N 11 2 9 25-17 M 42 36 6 25-19★ I 19 19 25-20 N 30 10 13* 4 3 25-24★ I 24 12 12 25-26 I 25 16 5 4 25-29★ I 29 29 25-35 M 128 128 25-37★ I 37 37 25-43 I 43 23 20 25-46 I 46 40 4 2† 25-61 I 61 61 ★ Ground plane proprietary option available. Arrg. 9-5 is exclusively ground plane type.
ms3102 | Amphenol Global Search | Amphenol
Receptacles: MS3100, MS3102, MS3101, 97-3101, 97-3100, 97-3102; Other Non-MIL-Mates, Flange Mounted. Flange Mounted Plug: FP3106, 97-5105; Thru-bulkhead Receptacle: TBF; See also 10-74XXX and 10-873XX in catalog section MIL-DTL-5015 Mods. for jam nut receptacles (Non-MIL) Alternate Positions of Insert Arrangements ... Search Results for ms3102a ...
Data Sheet R-Series V RP5 Analog - Temposonics
2 Temposonics® R-Series V RP Analog 5 3 1 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (waveguide) Position magnet (magnetic fi eld)
Data Sheet R-Series V RDV Analog - Temposonics
2 Temposonics® R-Series V RDV Analog 3 1 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (waveguide) Position magnet (magnetic fi eld)
Product Data Sheet - Temposonics
of less than ± 20 microns (0.0008 in.). For stroke lengths over 5000 mm (197 in.) the linearity accuracy is improved up to a factor of 10. ... (1.97 in.) 68 mm (2.68 in.) Figure 4. R-Series Model RP Profile-style sensor dimension reference (Shown with the : D53 : connector option)
Product Data Sheet - Temposonics
Up to 20 simultaneous magnet measurements are possible when using multiple magnets. The minimum allowed distance between magnets is 75 mm (3 in.) to maintain proper sensor output (see ‘Figure 2’). Figure 2. 1 to 20 magnet Measurement M1 M2 M19 M20 75 mm (3 in.) min. M3 Position / Velocity Temposonics® R-Series R ® Single to multi-magnet ...
MIL-C-5015 PRODUCT SHORTFORM - Amphenol Australia
18 34.93 26.97 4.0 19.05 3.05 26.0 1-20 NEF 20 38.10 29.36 4.0 19.05 3.05 29.0 1 1/4-18 NEF 24 44.45 34.93 4.0 20.63 3.73 35.5 1 1/2-18 NEF . Amphenol Australia www.amphenol.com.au ph 03 8796 8888 22 Industry Blvd, Carrum Downs VIC 3201 MIL-C-5015 PRODUCT SHORTFORM Metric Adaptor Part# 97B-14S-M16*1.5 ...
Amphenol Series SJT
20 000m V (coupled) 30 000m V (coupled) Recommended max. operating voltage at sea level Test voltage (eff.) M 4001300 800550 800 800 ... Contact arrangement 14-18 14-19 14-35 14-97 Number of contacts 18 19 37 4/8 Contact size 20 20 22 D 16/20 Voltage class I I M I Image (contact arrangement)
ANALOG - Temposonics
Current: 4 (0) to 20 mA, 20 to 4 (0) mA Maximum load: † 500 ‰ Measuring Range: Profile Style Sensors (PB): 50 to 5000 mm (2 to 196 in.) Rod Style Sensors (RH): 50 to 7600 mm (2 to 300 in.) Velocity: Velocity output range: 0.1 to 10 m/s or 1.0 to 400.0 in/s Minimum velocity: 1.0 in/s or 0.05 x stroke length in inches, whichever is greater
Industrial Interconnect System - Amphenol Sine
VV lin - lin - ee 2 V-line’s design includes a one piece 5 keyed shell, coupling nut, cable adapter and gland nut constructed of high strength machined aluminum and finished in
SMA Cable Assemblies - Amphenol RF
Amphenol RF offers a full range of SMA Cable Assemblies designed for radio frequency applications. SMA Cable Assemblies feature all industry standard connector interfaces in between-series and in-series designs.
ALUMALITE - Amphenol PCD
Visit amphenolpcd.com ion ALUMALITE Ideal Where Lightweight Connector Support Is Needed • Commercial lightweight metal backshells • Comparable in weight, performance & price to composite
42127300 | Amphenol Global Search | Amphenol
Search Results for 42127300 fs1-r38-20a2-11 | Amphenol Global Search | Amphenol Model 621B51:High freq. laboratory ceramic shear ICP® accel, 100 mV/g, 0.8 to 20k Hz, 316L SS case, side exit, 10-32 conn., frequency sweep ISO 17025
Introduction to Piezoelectric Force Sensors | PCB Piezotronics
Power to operate ICP sensors is generally in the form of a low cost, 24-27 VDC, 2-20 mA constant current supply. Figure 4 schematically illustrates a typical ICP sensor system. PCB offers a number of AC or battery-powered, single or multi-channel power/signal conditioners, with or without gain capabilities for use with force sensors.
Signal Conditioning Basics | PCB Piezotronics
In addition to ease-of-use and simplicity of operation, ICP ® sensors offer many advantages over traditional charge output sensors, including: 1.) Fixed voltage sensitivity independent of cable length or capacitance. 2.) Low output impedance (<100 Ohms) allows signals to transmitted over long cables through harsh environments with virtually no loss in signal quality.