Low frequency machinery monitoring: measurement considerations
Low frequency monitoring of industrial machinery requires specialized sensors, instrumentation and measurement techniques. The primary goal when measuring low frequency vibrations is to minimize electronic noise from the sensor and monitoring instrument.
VIBRATION FUNDAMENTALS - PCB
Charge mode accelerometers' high impedance signal requires conversion to a low impedance voltage signal prior to being processed by data acquisition or readout devices. The conversion can be done in two ways: Install cables to minimize connector strain using tape or clamps with service loops.
Accelerometer Limitations for Pyroshock Measurements - PCB
will be selected as a material to perform some representative calculations. Steel results in a calculated nominal velocity for the dilation wave (P wave) of 245,000 in./sec. Its distortional wave (S wave) has a calculated nominal velocity of 123,000 in./ sec. Again, the Raleigh wave has an intermediate velocity. Using the relationship:
Model 3743G112G Accelerometer, VC, 2g, triaxial, differential, screw ...
certified company whose calibration services are accredited by A2LA to ISO/IEC 17025, with full traceability to SI through N.I.S.T. In addition to our standard calibration services, we also offer specialized tests, including: sensitivity at elevated or cryogenic temperatur.
DataMate operating guide - Wilcoxon Sensing Technologies
96069 Rev B.1 10/18 6 of 20 2. Setting up DataMate 2.1.Setting up assets Begin setting up the software by entering the assets (machines) you are going to monitor.
Model 3711D1FA20G DC Accelerometer Installation and Operating Manual - PCB
• Perform ride quality assessments of elevators, automobiles, trains, and amusement park rides. • Analyze the low frequency characteristics of buildings, bridges, and large aerospace objects. • Acquire tilt and orientation data for feedback control and stabilization purposes.
Application guide for PC420V Series LPS™ transducers
Wilcoxon Sensing Technologies Tel: +1 (301) 330 8811 20511 Seneca Meadows Pkwy info@wilcoxon.com Germantown, MD 20876 www.wilcoxon.com
II e T - temposonics.com
Introduction to the Temposonics II Linear Displacement Transducer (L. n. Using the principle of magnetostriction (see Section 1.1, below), the Temposonics II LDT measures the time interval between the initiation of an interrogation pulse and the detection of a return pul.
Patrick L. Walter, Ph. D - PCB
3425 Walden Avenue, Depew, NY 14043-2495 USA Vibration Division toll free888-684-0013 24-hour SensorLineSM 716-684-0001 Fax 716-685-3886 E-mail vibration@pcb.com Web sitewww.pcb.com ISO 9001:2000 CERTIFIED A2LA ACCREDITED to ISO 17025
Tag Archives: DIN 41612 - amphenol-cs.com
Machines in chemical, petrochemical, food, beverage, oil, gas, pharmaceutical, and energy industries perform synchronized tasks.
CHARGE MODE ACCELEROMETERS - PCB
Charge mode accelerometers for industrial and power generation applications can be broadly categorized around three distinct operating temperature maximums: A variety of mechanical designs are used to perform the transduction required of charge accelerometers. The designs consist of sensing crystals that are attached to a seismic mass.
Model 3713B1250G/-0005 Triaxial DC Response Accelerometer Installation ...
Perform ride quality assessments of elevators, automo-biles, trains, and amusement park rides. Analyze the low frequency characteristics of buildings, bridges, and large aerospace objects. Acquire tilt and orientation data for feedback control and stabilization purposes.
Model 3713F1130G Platinum Stock Products; Triaxial MEMS DC ... - PCB
• mass. A high natural frequency is accomplished through the Perform ride quality assessments of elevators, automobiles, trains, and amusement park rides. ness. • Analyze the low frequency characteristics of buildings, bridges, and large aerospace objects. • Acquire tilt and orientation data for feedback control and stabilization purposes.
Model 3741E12200G DC Response Accelerometer Installation and ... - PCB
egral amplifier provides a low impedance output to follow-on instrumentation. These particular accelerometers provide a dc or steady state acceleration measurement capability as opposed to a predetermi.
Models 2680M1/2685M1 - PCB
NDCO www endevco com Te: 1 ( 866) ENDECO 1 ( 866) 363-3826 IM 2680/5 083119 4 Lower Cutoff Upper Cutoff Dash number-10% frequency
Model 340A50 Triaxial, miniature (11 gm) charge output accel., 2. ... - PCB
tructured accelerometers offer high performance for precision vibration measurements in high-temperature environments. The use of sensing crysta. s, operating in the shear mode, reduces erroneous output due to base strain, thermal transients, and transver.
Model 357M168 Charge Output Accelerometer Installation and ... - PCB
accelerometers, several important precautionary measures must be followed. When using soft-line cable always use special low-noise PCB Series 045 Low-Noise Cable (or equivalent) f. connecting to the input of the differential charge-output accelerometers. For extremely hig.
Model 201B03 ICP® quartz force ring, 500 lb comp., 10 mV/lb ... - PCB
Model 201B03 ICP® quartz force ring, 500 lb comp., 10 mV/lb Installation and Operating Manual For assistance with the operation of this product,
Model 357B33 High temp., ceramic shear, charge output accel., 100 pC/g ...
Model 357B33 High temp., ceramic shear, charge output accel., 100 pC/g, 3k Hz, 10-32 side conn. (-95 F to +500 F) Installation and Operating Manual
Model 300A12 ESS accel. kit including charge accel, cable, and in ... - PCB
Model 300A12 ESS accel. kit including charge accel, cable, and in-line charge converter, providing 10 mV/g Installation and Operating Manual This manual contains the 357M50, 422M136 installation and operating manuals that comprise