Search Results for arduino port mapping
Applying Offsets to Measurements - marport.com
You need to give a trawl node to the sensor. It is the number corresponding to the position of the sensor on the trawl.
Waterproof Micro USB 2.0 | Input Output Connectors | Amphenol
Amphenol Waterproof Micro USB 2.0 comes with full shielding that protects against Electromagnetic Interference (EMI), Radio-Frequency Interference (RFI), and Electromagnetic Discharge (ESD). They have power contact ratings of 1.8A and 3A that support
Cerbo GX - Gemeco
With its Dual Core Processor and the addition of an extra CAN-bus port you can now support even bigger systems; closely follow managed (lithium) batteries while the second port can support up to 25 simultaneously connected VE.Can solar chargers. The new NMEA 2000-out support has the GX easily integrated into any boats network.
Part No. 550033 Rev. E - Temposonics
GENERAL INFORMATION MTS PHONE NUMBERS Application questions: 800-633-7609 Repair Service: 800-248-0532 Fax: 919-677-0200 SHIPPING ADDRESS MTS Systems Corporation
High Speed Edge Launch PCB Connectors - SV Microwave
Impedance (Ω) 50; Frequency GHz: 18 GHz (select models to 26.5 GHz) Shielding Effectiveness: ≥ -90 dB; Dielectric withstanding Voltage: 1000 VRMS; Mating Cycles
2M805 2M804 2M803 2M801 - Amphenol Aerospace
56 Contact Us: 800-678-0141 • www.amphenol-aerospace.comContact Us: 800-678-0141 • www.amphenol-aerospace.com 2M805 Series of Hermetic Receptacles provide superior sealing of 1x10-8 cc/second helium leak rate and are 100% tested prior to shipping. This superior sealing is
Defense | Markets - Amphenol
Amphenol is a world leader in the design, manufacture and supply of high-performance interconnect systems for harsh environment defense applications including vibration, pressure, humidity, nuclear radiation and severe temperature changes.
2.92mm Female Solderless PCB Compression Mount Connector, 2 Hole, with ...
Discover a 2.92mm Female Solderless PCB Compression Mount Connector, 2 Hole, with 6.35mm Screws (Stripline) SF1521-60061-2S at SV Microwave.
P319 50/200kHz, 600W, Humminbird #9, DT - airmar-emea.com
600 W. Airmar’s entry-level P319 features a single, 50/200 kHz, dual-frequency, ceramic element in a low-profile, plastic housing. The nearly-flush design minimizes drag with only 5 mm (3/16") extending outside of the hull.
TNC Straight Receptacle Jack Solder Cup 4-Hole Flange 50 Ohm
RF Connector TNC Straight Receptacle Jack Solder Cup 4-Hole Flange 50 Ohm
ANTENNAS FOR CELLULAR NETWORKS - Amphenol Antenna Solutions
2.7 m 2.0 m 1.4 m 4 | Antennas for Cellular Networks TwinLine Panel Antennas | February 2019 Ultra Low Band (ULB) 698-960 MHz Ultra Wide Band Array (UWB) 1695-2690 MHz 65° 14 ports 5980470P* 432 mm 17.2 dBi | T2-12° 17.2 dBi | T2-12° 17.1 dBi | T2-12°
AHDSeries A - amphenol-sine.com
AHD10-9-1939P-BP80 9 Position, Jam Mount Receptacle, AHD Series™ J1939, Type 2, Threaded Rear, Green Body 2 AHD10-9-1939PE 9 Position, Square Flange Receptacle, AHD Series™ J1939, Type 1, Threaded Rear,
Aerospace - アンフェノールジャパン株式会社
Amphenol® High Frequency Contacts Twinax Twinax High Frequency contacts contacts catalog): • Amphenol® • Amphenol® • Amphenol® ® ® Aerospace.
Model 111A Charge Output Pressure Sensor Installation and ... - PCB
Drawing Number: 21067 Revision: A PIEZOELECTRIC CHARGE MODE PRESSURE SENSOR GENERAL OPERATION MANUAL 1 1.0 INTRODUCTION Quartz charge mode pressure sensors offer high
Safety Guidelines - Marport
Read this section before using the product. Important: To ensure proper and safe use of this equipment, carefully read and follow the instructions in this manual.
Checking Noise Interference - marport.com
Click Add to create a new page on which you will add the spectrum analyzer(s).; Right-click the IP address of the receiver in the status bar and click Start Spectrum. Open the control panels and go to the Mx panel.; Go to Hydrophone data, then drag and drop Spectrum data to a page. These data appear only when the spectrum has been started.
Model 112A **OBSOLETE** See 112A03 High sensitivity pressure ... - PCB
Model 112A **OBSOLETE** See 112A03 High sensitivity pressure probe, 3000 psi, 1 Installation and Operating Manual For assistance with the operation of this product,
Cross Reference - Airmar
AIRMAR provides information in this cross-reference as a guideline for choosing the correct transducer for your specific fishfinder. Our OEM customers frequently change their models, software versions and plug configuration, which may not be reflected in this cross-reference guide.
Brief Instruction R-Series - Temposonics
Temposonics® R-Series Brief Instructions I 3 I 1. Introduction 1.1 Purpose and use of this manual Before starting the operation of Temposonics® position sensors, read this documentation thoroughly and follow the
B175 Medium Ultra-Wide Chirp, 1kW, 20° Tilt, Humminbird #9, DT
The B175MW takes transducer design and performance to a whole new level by using medium frequency (60-100 kHz) with an incredible ultra-wide beamwidth ranging from 57-73° port-starboard to 16° average fore-aft.