Search Results for axr-5
Model M602D02 Low profile, industrial, ceramic shear ICP® accel., 500 ...
Low profile, industrial, ceramic shear ICP® accel., 500 mV/g, 0.5 to 8000 Hz, side exit, 2-pin connector, single point ISO 17025 accredited calibration Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour SensorLine: 716-684-0001 Fax: 716-684-3823
Model 119B High frequency pressure sensor, 80k psi, 0.25 pC/psi, accel ...
.200 16.5 20 .50 6.6 50 1.0 3.3 100 Passage Resonance vs. Passage Length Actual resonant frequencies measured in practice may differ slightly from the chart values. These differences are due to variations in the velocity of propagation of sound in air caused by changes in temperature and pressure of the air in the passage. ...
Model 607A12 Industrial ICP® Accelerometer Installation and Operating ...
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 113B27 High frequency ICP® pressure sensor, 100 psi, 50 mV ... - PCB
installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these models is at electrical ground potential. Series 113B3are similar to the x Series with an B2x additional feature; all Invar construction. The all Invar sensors are designed to have minimal susceptibility to thermal transient events and are
Model 3713F1110G Platinum Stock Products; Triaxial MEMS DC ... - PCB
5.0 Sensor Installation . When choosing an installation technique, be certain to care-fully examine the different application characteristics that may affect sensor performance. Characteristics such as mounting lo-cation may limit the use of large mounting blocks or the ampli-
5X - PCB
1 1 2 2 a a b b code ident. no. 52681 dwg. no. scale: sheet drawn checked engineer title unless otherwise specified tolerances are: dimensions in millimeters
Model 603M170 Industrial ICP® Accelerometer Installation and ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 027125-04051 PCB L&T Hand Torque Wrench, 50 in-lb (5.6 Nm), 8 ...
PCB L&T Hand Torque Wrench, 50 in-lb (5.6 Nm), 8-inch Handle, 1/4-inch Square Drive, 4-Pin PT Receptacle Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987
B175H Chirp-ready Tilted Element Thru-hull - Airmar
1 kW. Airmar’s low-profile, Chirp-ready, transducer models are the perfect addition to smaller boats such as center consoles. The high-frequency band delivers a narrow beamwidth—excellent for pinpointing fish holding tight to wrecks, reefs, and other structures.
Amphenol Aerospace
Amphenol Aerospace
Product Data Sheet - Temposonics
MTS Sensors R-Series Models RP and RH Temposonics® Linear-Position Sensors - Profinet Industrial Profinet Interface Product Data Sheet, Part No.: 551451, Revision A 08/13 6 Sensor mounting Model RP profile-style sensor mounting flexible installation in any position! Temposonics Model RP profile-style sensors offer two basic mounting methods; side grooves for use with mounting feet or a bottom ...
Considerations for Accelerometer Mounting on Motors - PCB
Considerations for Accelerometer Mounting on Motors - PCB
Model HT426E01 Microphone Preamplifier Installation and Operating ... - PCB
8.0 Warranty and Service..... 5 1.0 Introduction Thank you for your purchase of a PCB high quality microphone. These microphones offer highly accurate and reliable acoustic measurements and are typically used in research and design applications. They are accurate enough for laboratory usage, yet rugged enough for field-testing. ...
Model M102B15 High frequency ICP® pressure sensor, 200 psi, 25 ... - PCB
installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these models is at electrical ground potential. Series 113B3are similar to the x Series with an B2x additional feature; all Invar construction. The all Invar sensors are designed to have minimal susceptibility to thermal transient events and are
Model 3713E112G Triaxial MEMS DC accelerometer, 1000 mV/g, +/-2 g ... - PCB
5.0 Sensor Installation . When choosing an installation technique, be certain to care-fully examine the different application characteristics that may affect sensor performance. Characteristics such as mounting lo-cation may limit the use of large mounting blocks or the ampli-
Model 603C01/ICS-14 Industrial ICP® Accelerometer Installation ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 629A30 Precision Triaxial Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 378A04 MICROPHONE AND PREAMPLIFIER, LOW NOISE, 1/2 FREE ... - PCB
8.0 Warranty and Service..... 5 1.0 Introduction Thank you for your purchase of a PCB high quality microphone. These microphones offer highly accurate and reliable acoustic measurements and are typically used in research and design applications. They are accurate enough for laboratory usage, yet rugged enough for field-testing. ...
Model 113B22PBO High frequency ICP® pressure sensor placebo version of ...
installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these models is at electrical ground potential. Series 113B3are similar to the x Series with an B2x additional feature; all Invar construction. The all Invar sensors are designed to have minimal susceptibility to thermal transient events and are
SMP Female R/A to 2.92mm Male 12" Cable Assembly for .047 Cable
26.5 GHz : Impedance 50 ohms : Dielectric withstanding Voltage 500 VRMS : Shielding Effectiveness ≥ -80 dB DC - 3 GHz, ≥ -65 dB 3 - 26.5 GHz : Mechanical Mating Cycles - SB ...