Search Results for axr-5
Model 377A07 Precision Condenser Microphone Installation and Operating ...
8.0 Warranty and Service..... 5 1.0 Introduction Thank you for your purchase of a PCB high quality microphone. These microphones offer highly accurate and reliable acoustic measurements and are typically used in research and design applications. They are accurate enough for laboratory usage, yet rugged enough for field-testing. ...
Model 3711F11100G Single Axis MEMS DC accelerometer, 14 mV/g ... - PCB
Model 3711F11100G Single Axis MEMS DC accelerometer, 14 mV/g, +/-100 g, 1/4-28 4-Pin Plug Installation and Operating Manual For assistance with the operation of this product,
ICP® PRESSURE SENSOR - pcb.com
Measurement Range(for ±5V output) 5 kpsi 34,475 kPa Useful Overrange(for ± 10V output) 10 kpsi 68,950 kPa [1] Sensitivity(± 15 %) 1.0 mV/psi 0.145 mV/kPa Maximum Pressure(Total) 15 kpsi 103,425 kPa Resolution 100 mpsi 0.690 kPa [2] Resonant Frequency ≥ 250 kHz ≥ 250 kHz
PRODUCT DATA DRAWING REV DESCRIPTION - NRN 48172 04/24 SEE PDM
5) surface roughness 63 e mil-std-10. 6) dia.’s on common centers to be concentric within .005 t.i.r. 7) remove all burrs unless otherwise specified 7083-0004 www.svmicrowave.com title: proprietary the information contained in this drawing is the sole property of sv microwave, inc. any reproduction in part or as a whole without the written ...
Model 102B18 High frequency ICP® pressure sensor, 50 psi, 100 mV ... - PCB
installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these models is at electrical ground potential. Series 113B3are similar to the x Series with an B2x additional feature; all Invar construction. The all Invar sensors are designed to have minimal susceptibility to thermal transient events and are
Model M101A05 General purpose ICP® pressure sensor, 100 psi, 50 mV/psi ...
Model M101A05 General purpose ICP® pressure sensor, 100 psi, 50 mV/psi, M10x1.0 mtg thd, ground isolated Installation and Operating Manual For assistance with the operation of this product,
Model 121A21 Industrial ICP® pressure sensor, 100 psi, 50 mV/psi, 1/4 ...
Stay within the recommended torque range [(5-7 ft-lbs (0.6-0.8 Nm)] when mounting the sensor. It is advisable to use pipe joint compound to assure a tight seal. Use good machining practice in preparing the mounting port. Make sure the seal surface is free of tool chatter marks. Note: Nicks, scratches, or other discontinuities in
www.kayeinstruments.com
Created Date: 5/15/2014 7:31:50 AM
PRODUCT DATA DRAWING REV DESCRIPTION A DCN 52683 07/23
5) surface roughness 63 e mil-std-10. 6) dia.’s on common centers to be concentric within .005 t.i.r. 7) remove all burrs unless otherwise specified 7032-6728-xxx www.svmicrowave.com title: proprietary the information contained in this drawing is the sole property of sv microwave, inc. any reproduction in part or as a whole without the ...
Model 3711B1230G MEMS DC accelerometer, 67 mV/g, +/-30 g range, 0 ... - PCB
5.0 Sensor Installation . When choosing an installation technique, be certain to care-fully examine the different application characteristics that may affect sensor performance. Characteristics such as mounting lo-cation may limit the use of large mounting blocks or the ampli-
Model 607A62 Industrial ICP® Accelerometer Installation and ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 137B23A Quartz, free-field, ICP® blast pressure pencil ... - PCB
5.0 CALIBRATION Do not try to calibrate the Series 137B2XX statically. The Series 137B2XX is calibrated dynamically by PCB using a hydraulic pulse technique. For best accuracy, use the calibration certificate supplied. Factory recalibration is available for a nominal charge. 6.0 MAINTENANCE
Model 626B02 Low freq., industrial, ceramic shear ICP® accel ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 3713F112G Triaxial MEMS DC accelerometer, 675 mV/g, 2 g ... - PCB
5.0 Sensor Installation . When choosing an installation technique, be certain to care-fully examine the different application characteristics that may affect sensor performance. Characteristics such as mounting lo-cation may limit the use of large mounting blocks or the ampli-
Model HT356A34 Triaxial ICP® Accel., 50 mV/g, 100 g, 1 to 4 kHz, 6.6 gm ...
Model HT356A34 Triaxial ICP® Accel., 50 mV/g, 100 g, 1 to 4 kHz, 6.6 gm, 1/4-28 4-pin conn., adhesive mt., Titanium Hsg, extended temp 325F Installation and Operating Manual
Model M102A07 High resolution ICP® pressure sensor, 50 psi, 100 ... - PCB
The output bias voltage of the Model 112A23 is 5.0 volts, half the bias voltage of most PCB pressure sensors. This will cause the bias monitor meter on PCB power supplies to read at the low end of the green band. 5.0 POLARITY This sensor series produces a positive-going output voltage for increasing pressure input.
Model 101A02 General purpose ICP® pressure sensor, 5000 psi, 1 ... - PCB
Model 101A02 General purpose ICP® pressure sensor, 5000 psi, 1 mV/psi, 3/8-24 mtg thd, ground isolated Installation and Operating Manual For assistance with the operation of this product,
Quick-Connex® Mini Wiring System Accessories - TPC Wire
Cordsets M12 DC Micro Cordsets AC Micro Cordsets M8 Nano Cordsets Mini Cordsets 167 Valve Connection Cordsets Ethernet Cordsets Amphenol TPC Wire Cale / SA 800-21-79 / Canada 800--0122 / Mexico 001-877-28-1696 / tpcwire.com efiatns suet t ane Fr ete sefiatns an aaat as ur aes eresentate r a
Model 629A61 Precision Triaxial Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 137B22A Quartz, free-field, ICP® blast pressure pencil ... - PCB
5.0 CALIBRATION Do not try to calibrate the Series 137B2XX statically. The Series 137B2XX is calibrated dynamically by PCB using a hydraulic pulse technique. For best accuracy, use the calibration certificate supplied. Factory recalibration is available for a nominal charge. 6.0 MAINTENANCE