Model 605B91 Biaxial ICP® Accelerometer Installation and ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 261B12 Triax force link, charge, 1000 lb (Fx,y,z), 15 pC/lb (z ...
Model 261B12 Triax force link, charge, 1000 lb (Fx,y,z), 15 pC/lb (z), 32 pC/lb (x,y), ground isolated Installation and Operating Manual For assistance with the operation of this product,
Model 602M64 Industrial 3-Wire Accelerometer Installation and Operating ...
Size (Length x Width x Height) 1.65 in x 0.74 in x 0.845 in 41.9 mm x 18.8 mm x 21.5 mm Weight 2.61 oz 74.0 gm Mounting Thread 1/4-28 Male No Metric Equivalent [5] Mounting Torque 2 to 5 ft-lb 2.7 to 6.8 Nm Sensing Element Ceramic Ceramic Sensing Geometry Shear Shear Housing Material Stainless Steel Stainless Steel Sealing Welded Hermetic ...
Model 3743F1110G Accelerometer, VC, 10g, triaxial, damped ... - PCB
5.0 Sensor Installation . When choosing an installation technique, be certain to care-fully examine the different application characteristics that may affect sensor performance. Characteristics such as mounting lo-cation may limit the use of large mounting blocks or the ampli-
Model 638A06 Cryogenic, industrial, quartz shear ICP accel, 25 mV ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Repair and Maintenance Returning Equipment Contact Information ... - PCB
Model 54102-01 Locator Pin 5mm OD x 5.8mm long (1) Model ICS-7 NIST traceable triaxial amplitude response calibration from 10 Hz to upper +/-3dB point. PIN OUT 1 1 2 2 A A B B CODE IDENT. NO. 52681 DWG. NO. SCALE: SHEET DRAWN CHECKED ENGINEER TITLE UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:
Model 123B23 Rocket motor ICP® pressure sensor 10k psi 0.5mV/psi Helium ...
Model 123B23 Rocket motor ICP® pressure sensor 10k psi 0.5mV/psi Helium bleed water-cooled (replaceable tubes) Installation and Operating Manual
Amphenol PCD Shenzhen
We would like to show you a description here but the site won’t allow us.
Model 039237-50022/B Rotary Torque Angle Transducer, w/Auto-ID ... - PCB
Power Required … 5 VDC @ 120 mA max. Recommended Max RPM ¼-in Drive … 5000 3/8-in Drive … 2500 ½-inch Drive … 2500 ¾-in Drive … 2000 1-in Drive … 1000 1 ½-in Drive … 750 2 ½-in Drive … 500 . RS Technologies Division of PCB Load & Torque, Inc. Toll-Free in USA 888-684-2894 716-684-0001 www.pcbloadtorque.com ...
Model 039201-53102 PCB L&T Rotary Torque Angle Transducer, w/Auto-ID ...
Power Required … 5 VDC @ 120 mA max. Recommended Max RPM ¼-in Drive … 5000 3/8-in Drive … 2500 ½-inch Drive … 2500 ¾-in Drive … 2000 1-in Drive … 1000 1 ½-in Drive … 750 2 ½-in Drive … 500 . RS Technologies Division of PCB Load & Torque, Inc. Toll-Free in USA 888-684-2894 716-684-0001 www.pcbloadtorque.com ...
Model 039037-50022 PCB L&T Rotary Torque Only Transducer, w/Auto-ID ...
Power Required … 5 VDC @ 120 mA max. Recommended Max RPM ¼-in Drive … 5000 3/8-in Drive … 2500 ½-inch Drive … 2500 ¾-in Drive … 2000 1-in Drive … 1000 1 ½-in Drive … 750 2 ½-in Drive … 500 . RS Technologies Division of PCB Load & Torque, Inc. Toll-Free in USA 888-684-2894 716-684-0001 www.pcbloadtorque.com ...
PT SERIES - Amphenol-Air LB
5.07 Contact size 20 16 Load in the axial direction N min. 68 113 Mounting nut of PT 07 Backshell Shell size Torque Shell size Torque Nm + 0.5 Nm 8 3.6 8 4 + 0.5 10 4.110 6 + 0.5 12 5.212 8 ± 1.0 14 6.214 10 ± 1.0
TYPE CONNECTOR CABLE (CABLE) HT X 03 F 005 H5 F 25 - TPC Wire
5 = “005” 50 = “050” 500 = “500” Cable Type (Must Be Two Digits): H5 EXAMPLES:= Heat Trace 5 Watts/Ft, 120 V Cable Length 1 (Must Be Three Characters): 5 = “005” 50 = “050” 500 = “500” Unit of Measure 2: M = Meters F = Feet A = Inches UOM 1 CABLE LENGTH (FT) UOM 2 MAX HEAT TRACE CABLE (FT) 25 Up to 350 50 Up to 345 75 Up ...
Model 357B40 Miniature (4 gm), charge output accel., 5 pC/g, 0.40-inch ...
Miniature (4 gm), charge output accel., 5 pC/g, 0.40-inch cube, 10-32 side conn. Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com.
Model 102B15 High frequency ICP® pressure sensor, 200 psi, 25 mV ... - PCB
installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these models is at electrical ground potential. Series 113B3are similar to the x Series with an B2x additional feature; all Invar construction. The all Invar sensors are designed to have minimal susceptibility to thermal transient events and are
VQ31 Series Thermal Conductivity Gas Detector Elements
H 1.5 * sensing element 6.25 + 0.50 reference element 7.75 + 0.38 SGX Sensortech(IS) Ltd Registered in England No.08067077 A1A-VQ31_Ser Issue 6, March 2007. SENSING ELEMENT EXPOSED TO GAS UNDER TEST REFERENCE ELEMENT SEALED OFF FROM GAS UNDER TEST 60 MESH STAINLESS STEEL GAUZE FLOW RATE 500 cm3/min
Model M628F01 Precision Quartz Industrial ICP® Accelerometer ...
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model M102B16 High frequency ICP® pressure sensor, 100 psi, 50 ... - PCB
installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these models is at electrical ground potential. Series 113B3are similar to the x Series with an B2x additional feature; all Invar construction. The all Invar sensors are designed to have minimal susceptibility to thermal transient events and are
Model 3743F11100G Accelerometer, VC, 100g, triaxial, damped ...
5.0 Sensor Installation . When choosing an installation technique, be certain to care-fully examine the different application characteristics that may affect sensor performance. Characteristics such as mounting lo-cation may limit the use of large mounting blocks or the ampli-
ROHS Declaration - Wilcoxon Sensing Technologies
Wilcoxon Sensing Technologies 8435 Progress Drive Frederick , MD 2 1701 USA Amphenol (Maryland), Inc ., d/b/a Wilcoxon Sensing Technologies