Search Results for axr-5
Model 626A04 Seismic Industrial ICP® Accelerometer Installation ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 105C Subminiature ICP® pressure sensor, 100 psi, 50 mV/psi ... - PCB
The electrical connection is made via a 5-44 coaxial connector. Use coaxial 002G10 cable, 5-44 to 10-32 microdot. Drawing Number: 21106 Revision: NR OPERATION MANUAL FOR
Model 352B30 Ceramic shear ICP® accel., 10 mV/g, integral 10-32 ... - PCB
Model 352B30 Ceramic shear ICP® accel., 10 mV/g, integral 10-32 mtg stud, 10-32 top conn. Installation and Operating Manual For assistance with the operation of this product,
Model W106B/002C10 OBS PER ECN 46295, 46466 Installation and ... - PCB
Sensitivity(± 15 %) 300 mV/psi 43.5 mV/kPa Maximum Pressure(step) 200 psi 1,379 kPa Maximum Pressure 2,000 psi 13,790 kPa [1] Resolution 0.0001 psi 0.00069 kPa [1] Resonant Frequency ≥ 60 kHz ≥ 60 kHz Rise Time ≤ 9 µ sec ≤ 9 µ sec Low Frequency Response(- 5 %) 0.5 Hz 0.5 Hz
2M803 1/4-Turn Bayonet Coupling Lightweight Connectors
2M803 micro-miniature circular connectors are very light; and their fast, sure-mate bayonet coupling makes them the perfect choice for light-duty applications that require frequent disconnect.
Model 137B24B Quartz, free-field, ICP® blast pressure pencil ... - PCB
5.0 CALIBRATION Do not try to calibrate the Series 137B2XX statically. The Series 137B2XX is calibrated dynamically by PCB using a hydraulic pulse technique. For best accuracy, use the calibration certificate supplied. Factory recalibration is available for a nominal charge. 6.0 MAINTENANCE
All Categories On Amphenol NEXUS Technologies
Created Date: 8/23/2006 10:05:09 AM
Model 607M126 Industrial ICP® Accelerometer Installation and Operating ...
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model HT602D01 Industrial ICP® Accelerometer Installation and ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 685A39 Linear Adjust Mechanical Vibration Switch ... - PCB
PAGE 5 TRUME HINE G Remote Reset and Power On Delay Models 685A19, 685A29 and 685A39 have provisions to reset the switch remotely. The vibration switch can be remotely reset after being tripped by applying the correct voltage across the reset terminal as shown below. NOTE: There is no positive/negative polarity needed for the wiring. NOTE:
Model M602D02 Low profile, industrial, ceramic shear ICP® accel., 500 ...
Low profile, industrial, ceramic shear ICP® accel., 500 mV/g, 0.5 to 8000 Hz, side exit, 2-pin connector, single point ISO 17025 accredited calibration Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour SensorLine: 716-684-0001 Fax: 716-684-3823
Model 4115K-02A PCB L&T Torque Sensor, Rotary Transformer, 100 in-lb ...
angles `.5 degrees 24350 indoplex circle, farmington hills,mi 48335 (248) 888-8260 e-mail: ltinfo@pcb.com dimensions in inches.5 degrees fillets and radii .015 max fillets and radii 0.38 max outline drawing 22675 5 / 8 1 of 1 model 4115k series rotary transformer pte 5/27/22 decimals xx ±.01 xxx ±.005 decimals x ± 0.3 xx ± 0.13 a a 2 2 6 7 5
Jumper Cables - Amphenol Antenna Solutions
Designed for outdoor applications under extreme conditions with high flexibility and small bending diameters. Available in a variety of cable lengths and connector combinations.
Model M102B15 High frequency ICP® pressure sensor, 200 psi, 25 ... - PCB
installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these models is at electrical ground potential. Series 113B3are similar to the x Series with an B2x additional feature; all Invar construction. The all Invar sensors are designed to have minimal susceptibility to thermal transient events and are
AN ADVANCED TORQUE AUDITING METHOD - PCB
fastener 5° to 10° in the tightening direction and then observing the peak torque. The acceptability of the joint tightness is then determined by comparing the peak torque from the audit reading to the installation torque value. Often, this method accomplishes little more than to verify the performance of the tool that
Model 629A30 Precision Triaxial Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 354A05 Triaxial ICP® Accelerometer Installation and ... - PCB
Supplied Accessory : Model M081A103 Mounting screw and washer, M3 x 0.5 thread (1) replaces Model 081A105 NOTES: [1] Typical. [2] Zero-based, least-squares, straight line method. [3] TEDS Capable Digital Memory and Communication, compliant with IEEE 1451.4
3 Single Pair Ethernet - アンフェノールジャパン株式会社
3 Mechanical interfaces IP67 and above for industrial and ruggedized applica ons 3dom of choices for your needs and requirements 3 Budgets, pay for what you need Freedom of Choices and Budgets » ALTW’s proprietary SPE interface integrated in M8 (G8) / M12 / FLOS+ / X-Lok » Providing low power & simply networking on
Model 1424-01ADB FATIGUE RATED LOW PROFILE load cell, DUAL BRIDGE ...
ANGLES `.5 DEGREES 24350 Indoplex Circle, Farmington Hills,MI 48335 (716) 684-0001 E-MAIL: ltinfo@pcbloadtorque.com DIMENSIONS IN INCHES.5 DEGREES FILLETS AND RADII .015 MAX FILLETS AND RADII 0.38 MAX OUTLINE DRAWING 58129 3/8 1 OF 1 1424 SERIES LOW PROFILE LOAD CELL DEA 05.15.14 DECIMALS XX ±.01 XXX ±.005 DECIMALS X ± 0.3 XX ± 0.13 5 8 1 2 9
Model 105C22 Subminiature ICP® pressure sensor, 1 mV/psi, 0.099 ... - PCB
The electrical connection is made via a 5-44 coaxial connector. Use coaxial 002G10 cable, 5-44 to 10-32 microdot. Drawing Number: 21106 Revision: NR OPERATION MANUAL FOR