Search Results for axr-5
Model 119C12 High pressure ballistic pressure sensor, 120k psi, 0 ... - PCB
.200 16.5 20 .50 6.6 50 1.0 3.3 100 Passage Resonance vs. Passage Length Actual resonant frequencies measured in practice may differ slightly from the chart values. These differences are due to variations in the velocity of propagation of sound in air caused by changes in temperature and pressure of the air in the passage. ...
Model 109C12 High pressure ICP® ballistic pressure sensor, 100k ... - PCB
Model 109C12 High pressure ICP® ballistic pressure sensor, 100k psi, 0.07 mV/psi, accel. comp. (ceramic coated integral diaphragm) Installation and Operating Manual
REVISION HISTORY REV DESCRIPTION PRODUCT DATA DRAWING A DCN 52757 07/23
5) surface roughness 63 e mil-std-10. 6) dia.’s on common centers to be concentric within .005 t.i.r. 7) remove all burrs unless otherwise specified 7032-9735 www.svmicrowave.com title: proprietary the information contained in this drawing is the sole property of sv microwave, inc. any reproduction in part or as a whole without the written ...
RF Coaxial Connectors, Adapters and Cable Assemblies | Amphenol RF
Author: HyperGEAR,Inc. Created Date: 5/25/2010 3:25:15 PM
Model 121A21 Industrial ICP® pressure sensor, 100 psi, 50 mV/psi, 1/4 ...
Stay within the recommended torque range [(5-7 ft-lbs (0.6-0.8 Nm)] when mounting the sensor. It is advisable to use pipe joint compound to assure a tight seal. Use good machining practice in preparing the mounting port. Make sure the seal surface is free of tool chatter marks. Note: Nicks, scratches, or other discontinuities in
PRF-033, Rev 10 Page 1 of 28 - Borisch
52.212-5 Contract Terms Cand Conditions Required to Implement Statutes or Executive Orders – ommercial Items (Applies to solicitations and acquisition of commercial items; Alternate I applies when the head of the agency has waived the examination of records by the Comptroller General in accordance with FAR 25.1001.
132340 | Amphenol Global Search | Amphenol
L-2035-AN FSCM 77820 May 2007 21-33122-562 Amphenol Aerospace AMPHENOL CORPORATION Amphenol Aerospace 40-60 Delaware Avenue Sidney, New York 13838-1395 www.amphenol-aerospace.com CONTACT MUST BE SEATED.270 TRIM EXCESS SHIELD.240.108 DIA MAX OUTER PIN CONTACT SHIELD CRIMP SLEEVE FRONT INSULATOR REAR INSULA TOR COMB SHIELD FORWARD CONTACT MUST
Model 136A Tourmaline hydraulic pressure calibration transfer ... - PCB
5.0 CALIBRATION: The sensor is calibrated dynamically to a maximum pressure of 20 000 psi using a drop weight tester. NOTE: The oil in the hydraulic system must be non-conductive because the Model 136A has an exposed crystal. Silicon oil is recommended. Linearity is determined by taking at least five data
Model M355B12 Miniature (2 gm), ring-style, ceramic shear ICP ... - PCB
Model M355B12 Miniature (2 gm), ring-style, ceramic shear ICP® accel., 10 mV/g, 1 to 10k Installation and Operating Manual For assistance with the operation of this product,
172137 - Amphenol RF
Title: C:\Documents and Settings\gary.TESTUM-WS01.000\My Documents\Garry's\connex\SET_5\172137.dwg Author: gary Created Date: 12/14/2003 1:22:35 PM
Protimeter MMS3 Moisture Measurement System
Protimeter MMS3 Moisture Measurement System
Model 621B41 High Frequency ICP® Accelerometer Installation and ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 102M80A Cryogenic ICP pressure sensor, 100 psi, 50 mV/psi ... - PCB
mounting torque on a 5/8 hex: 120-130 in-lbs dimensions shown are for .36 wall thickness, counterbore for thicker walls 3 1 2.356.79 1.55 max safety wire holes co-axial 10-32 unf - 2a electrical connector with retaining ring 9/32 hex clamp nut 5/8 hex thread adaptor seal (k) rocketdyne pt. no. 12100cr4 (mtl 304) 7/16-20 unf - 2a 2 2 3 .454 .562 ...
Model M101A05 General purpose ICP® pressure sensor, 100 psi, 50 mV/psi ...
Model M101A05 General purpose ICP® pressure sensor, 100 psi, 50 mV/psi, M10x1.0 mtg thd, ground isolated Installation and Operating Manual For assistance with the operation of this product,
Model 637A06 Cryogenic, industrial, quartz shear ICP accel, 25mV ... - PCB
Transverse Sensitivity ≤ 5 % ≤ 5 % Environmental Overload Limit(Shock) 1,000 g pk 9,810 m/s² pk Temperature Range -320 to +250 °F -196 to +121 °C Temperature Response See Graph See Graph [3] Electrical Settling Time(within 1% of bias) ≤ 3 sec ≤ 3 sec Discharge Time Constant 0.05 to 0.5 sec 0.05 to 0.5 sec
Model 622B11 Precision Industrial ICP® Accelerometer Installation and ...
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model M622B01 Precision Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
00110027981 - Amphenol Air LB
00112021702 Crimp Terminal With seal #20 with fixing Ø 1,5 mm and length 2 mm . Amphenol Air LB. About us; Amphenol group; News; Careers; Contact us; Contact Information. Address 2 rue Clément Ader, Zac de Wé, 08110 Carignan France. Phone +33 3 24 22 78 49. Email accueil@amphenol-airlb.fr. Categories. Products ...
Model 137B22A Quartz, free-field, ICP® blast pressure pencil ... - PCB
5.0 CALIBRATION Do not try to calibrate the Series 137B2XX statically. The Series 137B2XX is calibrated dynamically by PCB using a hydraulic pulse technique. For best accuracy, use the calibration certificate supplied. Factory recalibration is available for a nominal charge. 6.0 MAINTENANCE
ICP® PRESSURE SENSOR - pcb.com
Measurement Range(for ±5V output) 5 kpsi 34,475 kPa Useful Overrange(for ± 10V output) 10 kpsi 68,950 kPa [1] Sensitivity(± 15 %) 1.0 mV/psi 0.145 mV/kPa Maximum Pressure(Total) 15 kpsi 103,425 kPa Resolution 100 mpsi 0.690 kPa [2] Resonant Frequency ≥ 250 kHz ≥ 250 kHz