Search Results for axr-5
Model 606B61 Low-cost Industrial ICP® Accelerometer Installation ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 039050-51201 PCB L&T Rotary Torque Only Transducer, w/Auto-ID ...
Power Required … 5 VDC @ 120 mA max. Recommended Max RPM ¼-in Drive … 5000 3/8-in Drive … 2500 ½-inch Drive … 2500 ¾-in Drive … 2000 1-in Drive … 1000 1 ½-in Drive … 750 2 ½-in Drive … 500 . RS Technologies Division of PCB Load & Torque, Inc. Toll-Free in USA 888-684-2894 716-684-0001 www.pcbloadtorque.com ...
PRODUCT DATA DRAWING
%PDF-1.6 %âãÏÓ 4 0 obj > endobj xref 4 42 0000000016 00000 n 0000001356 00000 n 0000001453 00000 n 0000001737 00000 n 0000001863 00000 n 0000003448 00000 n 0000004622 00000 n 0000005585 00000 n 0000006589 00000 n 0000006721 00000 n 0000007768 00000 n 0000007895 00000 n 0000009098 00000 n 0000010338 00000 n 0000011433 00000 n 0000011502 ...
Model M109C12 High pressure ICP® ballistic pressure sensor, 100k ... - PCB
Model M109C12 High pressure ICP® ballistic pressure sensor, 100k psi, 0.07 mV/psi, accel. comp. (ceramic coated integral diaphragm), metric mount
Mastering RJ45 Connectors: A Step-by-Step Guide for Installation on ...
As the backbone of modern networking, RJ45 Connectors play a pivotal role in establishing secure and efficient connections. We created an incredible instructional guide that takes you step-by-step on how to install RJ45 Field Installable Connectors for large Ethernet Cables such as CAT 7, CAT 6, and Profinet cables. Within the video and blog post provided, you will find a wealth of information ...
Model 101A05 General purpose ICP® pressure sensor, 100 psi, 50 ... - PCB
Model 101A05 General purpose ICP® pressure sensor, 100 psi, 50 mV/psi, 3/8-24 mtg thd, ground isolated Installation and Operating Manual For assistance with the operation of this product,
Model 607A62 Industrial ICP® Accelerometer Installation and ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 626B02 Low freq., industrial, ceramic shear ICP® accel ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
MiCs - SGX Sensortech
To test the MiCs-5914 (Ammonia sensor) only Jumper 2 and 5 should be installed. With these jumpers in place the circuit is: G F D 820 Ohms J1 Vout A 82 Ohms V+ V+ 100K Ohms G F DMiCs J5 J2 Vout A 93.1 Ohms-5914 Socket for MiCs Sensors J H G F D 820 Ohms A B C 820 Ohms 130 ohms 51K Ohms 100K Ohms 82 ohms J5 93.1 Ohms Jumpers 1-5 J1 0.1uF0.33 uF ...
Model 629A11 Triaxial, industrial, ceramic shear ICP® accel., 100 mV/g ...
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 117B184 Conformal ballistics Pressure Sensor for 40 Smith ... - PCB
or using 5/16 open end wrench. Do not tighten when sensor bottoms. 5. Now tighten the screw closing slotted clamp. 6. Using open end wrench, tighten sensor clamp nut. NOTE: It is not necessary to put large amounts of torque on this nut since a pressure seal is not necessary. Approximately 5 to 10 ft. lbs. is sufficient. 7.
PCB Piezotronics | Measure vibration, pressure, force, and more
PCB Piezotronics | Measure vibration, pressure, force, and more
Model 601A02/ICS-14 ACCELEROMETER LOW FREQUENCY 500mV/G Installation ...
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 354B05 Triaxial, Thru-hole mtg, Ceramic shear ICP® accel ... - PCB
Model Number 354B05 TRIAXIAL ICP® ACCELEROMETER Revision: A ECN #: 54323 Performance ENGLISH SI Sensitivity(± 5 %) 100 mV/g 10.2 mV/(m/s²) Measurement Range ± 50 g pk ± 491 m/s² pk Frequency Range(± 5 %) 0.6 to 10,000 Hz 0.6 to 10,000 Hz
Model 685A19 Linear Adjust Mechanical Vibration Switch Installation and ...
PAGE 5 TRUME HINE G Remote Reset and Power On Delay Models 685A19, 685A29 and 685A39 have provisions to reset the switch remotely. The vibration switch can be remotely reset after being tripped by applying the correct voltage across the reset terminal as shown below. NOTE: There is no positive/negative polarity needed for the wiring. NOTE:
Model 137B23A Quartz, free-field, ICP® blast pressure pencil ... - PCB
5.0 CALIBRATION Do not try to calibrate the Series 137B2XX statically. The Series 137B2XX is calibrated dynamically by PCB using a hydraulic pulse technique. For best accuracy, use the calibration certificate supplied. Factory recalibration is available for a nominal charge. 6.0 MAINTENANCE
Model 377A14 Precision Condenser Microphone Installation and ... - PCB
8.0 Warranty and Service..... 5 1.0 Introduction Thank you for your purchase of a PCB high quality microphone. These microphones offer highly accurate and reliable acoustic measurements and are typically used in research and design applications. They are accurate enough for laboratory usage, yet rugged enough for field-testing. ...
Model W113B32/003C05 High frequency Invar ICP® pressure probe ... - PCB
installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these models is at electrical ground potential. Series 113B3are similar to the x Series with an B2x additional feature; all Invar construction. The all Invar sensors are designed to have minimal susceptibility to thermal transient events and are
Model 4115A-04A Rotary Transformer Torque Sensor Installation and ... - PCB
Model 180-019A 5-socket mating connector for Series 3100, 4100, 4200 torque sensors Model 8113-105A Relay activated precision shunt calibration module PCB Load & Torque, Inc. 24350 Indoplex Circle Farmington Hills, MI 48335 UNITED STATES Phone: 866-684-7107 Fax: 716-684-0987