Search Results for axr-5
NovaSensor NPA Series Pressure Sensors
NovaSensor NPA Series Pressure Sensors
Model 3711F1130G Platinum Stock Products; Single Axis MEMS DC ... - PCB
5.0 Sensor Installation . When choosing an installation technique, be certain to care-fully examine the different application characteristics that may affect sensor performance. Characteristics such as mounting lo-cation may limit the use of large mounting blocks or the ampli-
Home - Amphenol Canada
The ARINC 600 catalog provides detailed information on connectors for avionics designs, featuring lower mating force contacts, increased contact count, and a front release keying system.
Model 109C11 High pressure ICP® ballistic pressure sensor, 80k ... - PCB
Model 109C11 High pressure ICP® ballistic pressure sensor, 80k psi, 0.07 mV/psi, accel. comp. (ceramic coated integral diaphragm) Installation and Operating Manual
MODEL 378A04 LOW NOISE MICROPHONE - PCB
minimum of 4 mA and measures to 6.5 dB(A) (5.5 dB(A) typical) within a cost efficient, prepolarized (0V) design. STANDARDS COMPLIANCE Calibration reference microphone traceable to NIST, PTB or DFM National Labs PCB calibration service accredited to ISO 17025, ANSI-Z540.3 by A2LA or ILAC. MODEL . 378A04. LOW NOISE . MICROPHONE
Amphenol CS Sales Office Locations | Office Addresses
Via Barbaiana 5 20020 Lainate (MI) Italy Tel. : +39 02 93254205; Netherlands 3992 DH Houten, Netherlands Tel. : +31 30 6358000; Sweden Amphenol CS Knarrarnäsgatan 7 SE-16440 Kista, Sweden ; AMERICA. Amphenol CS Sales Office Locations. California Amphenol CS 4500 Great America Pkwy Suite 310 Santa Clara, CA 95054
RF Coaxial Connectors, Adapters and Cable Assemblies | Amphenol RF
Author: HyperGEAR,Inc. Created Date: 5/25/2010 3:25:15 PM
Model HT602D61 High-temp Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model P119B11 Charge Output Pressure Sensor Installation and ... - PCB
.200 16.5 20 .50 6.6 50 1.0 3.3 100 Passage Resonance vs. Passage Length Actual resonant frequencies measured in practice may differ slightly from the chart values. These differences are due to variations in the velocity of propagation of sound in air caused by changes in temperature and pressure of the air in the passage. ...
ASR connectors - Backshells | Products Amphenol Air LB
Straight backshell 5 items; 90° angled backshell 4 items; Receptacle cover 4 items; 45° angled backshell 3 items; Show More. Amphenol Air LB. About us; Amphenol group; News; Careers; Contact us; Contact Information. Address 2 rue Clément Ader, Zac de Wé, 08110 Carignan France. Phone +33 3 24 22 78 49. Email [email protected] ...
Search Results - Temposonics
Temposonics ® Absolute,Non-ContactPositionSensors R-Serie Catalog 0.5 μm Analog CANbus Profibus-DP S. catalog_r-series_551303_en.pdf. Temposonics ® Absolute,Non-ContactPositionSensors R-Serie Catalog 0.5 μm Analog CANbus Profibus-DP S. sensor_selector_guide_industrial_551814_en.pdf. Sensor Selector Guide Magnetostrictive Linear Position ...
Model 137B23B ICP® Pressure Sensor Installation and Operating Manual - PCB
5.0 CALIBRATION Do not try to calibrate the Series 137B2XX statically. The Series 137B2XX is calibrated dynamically by PCB using a hydraulic pulse technique. For best accuracy, use the calibration certificate supplied. Factory recalibration is available for a nominal charge. 6.0 MAINTENANCE
FCE17 D-Sub Filter | Input Output Connectors | Amphenol
Get your sample by choosing part number(s) from the product page or using the search box above. Manually add part number(s) here
Equipment Issue 1 First Printing, December 2008 ... - Charles Industries
Ltd. offers 5-year warranty on this Smart Coil product. Contact your local Sales Representative at the address or telephone num-bers below for warranty details. The warranty provisions are subject to change without notice. The terms and conditions applica-ble to any specific sale of product shall be defined in the resulting sales contract.
G-Series Position Sensors - Temposonics
Temposonics ® G-Series linear position sensors provide high durability and accurate position measurement solutions in harsh industrial settings.. Different position sensor models for different purposes of position measurement: Rod version (GH) for cylinder integrated position measurement and for retrofitting legacysensor models
CG-L6 / CG-L8 Assembly Instructions - wilcoxon.com
5. Torque Locknut to ~ 66 in lb. 6. Loosen Cable Gland dome nut (no not remove) and feed cable(s) through hole(s) of Insert (item 2). 7. Install Plugs (item 4) into any unused Insert holes. Feed Plug from inside the enclosure, making sure the ‘tail’ is pulled completely through the Insert hole.
00206B44A103230525104059 - PCB
2. for us class 2258 04 - process control class 2258 84 - process control certified to u.s. standards
4X - PCB
5 lbs [22 n] of force to top of accelerometer creating a thin but homogeneous layer of wax recommended mounting surface should be flat to within .003 [0.08] tir over .375 [9.52] with a 32 [0.8] finish for best results 3 2 1 revisions rev description din nr released to drafting 45095
PL 1200RG N SERIES Plastic Shell Auto Connectors 78 pole capacity ...
PL-1200RG-N SERIES Plastic Shell Auto-Coupling Connectors 78 pole capacity interconnect system PL-1200RG-N FEATURES Specifically designed for electro-surgical catheter applications, the compact and cost effective PL-1200 Series offers more features, contacts and termination options than the competition
PCB Piezotronics | Measure vibration, pressure, force, and more
Created Date: 5/27/2014 1:31:06 PM
Fluid-Trac™ - ssi-sensors.com
The Fluid-Trac™ cost-competitive liquid level sensor family is ideal for tanks or storage containers that have a depth/height of 32 inches (24 inches for gasoline).
Model 105C22 Subminiature ICP® pressure sensor, 1 mV/psi, 0.099 ... - PCB
The electrical connection is made via a 5-44 coaxial connector. Use coaxial 002G10 cable, 5-44 to 10-32 microdot. Drawing Number: 21106 Revision: NR OPERATION MANUAL FOR
P51 Pressure Sensor - ssi-sensors.com
4.5 V = 0.5 - 4.5 V (5 V input only) 4.5 OVP = 0.5 - 4.5 V (5 V input only) Includes over voltage protection 5 V = 1 - 5 V (8 to 30 V input only) 20 mA = 4 - 20 mA (8 to 30 V input only) MOV = Option for 5 V and 20 mA for voltage spike protection *Other port configurations may be available. Consult factory. MOQ's apply. *Other harness lengths
Model 626B02 Low freq., industrial, ceramic shear ICP® accel ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
ABS14XX monoblock pipe clamps - Fuel zone | Products Amphenol Air LB
1 hole 5 items; 2 holes 3 items; Show More. Amphenol Air LB. About us; Amphenol group; News; Careers; Contact us; Contact Information. Address 2 rue Clément Ader, Zac de Wé, 08110 Carignan France. Phone +33 3 24 22 78 49. Email [email protected]. Categories. Products; Markets; Solutions; Know-how; Be the First to Know ...
Model M624B01 Precision Quartz Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
ment in this new connector series while meeting all of the requirements ...
Amphenol Aerospace | 11 Delaare Ae. | Sidney 133 | -11 | amphenol-aerospace.com Introduction The changes in technology where R-VPX connectors are used has rapidly evolved in recent years, specifically driving a demand for higher data rates from copper contact based connectors, which have typically resided in the
REVISION HISTORY REV DESCRIPTION PRODUCT DATA DRAWING A DCN 52757 07/23
5) surface roughness 63 e mil-std-10. 6) dia.’s on common centers to be concentric within .005 t.i.r. 7) remove all burrs unless otherwise specified 7032-9735 www.svmicrowave.com title: proprietary the information contained in this drawing is the sole property of sv microwave, inc. any reproduction in part or as a whole without the written ...
TITLE: DWG NO - Amphenol Sine
2.5 2x keyway key a shown 5. part number arc16-24sx-p013 variants arc16-24sa-p013 of: sh: rev: dwg no: title: rev description date revisions eco by appr 2 2 a1 arc16-24sx-p013 24 pos, plug, socket,arc series,keyed, normal seal,black arc16-24sx-p013 materials list size process specifications:
Model 355A44 ICP® Accelerometer Installation and Operating Manual - PCB
Spectral Noise(10 kHz) 5 µg/√Hz 47 (µm/sec2)/√Hz [1] Electrical Isolation(Case) ≥ 108 Ohm Physical Size (Height x Length x Width) .32 in x 0.94 in x 0.46 in 8.1 x 23.8 mm x 11.7 mm Weight(without cable) .13 oz 3.6 gm [1] Sensing Element Ceramic Ceramic Sensing Geometry Shear Shear
1758 grounding modules | Products Amphenol Air LB
Size 20 5 items; Size 16 1 item; Size 12 1 item; Mixed 1 item; Show More. Amphenol Air LB. About us; Amphenol group; News; Careers; Contact us; Contact Information. Address 2 rue Clément Ader, Zac de Wé, 08110 Carignan France. Phone +33 3 24 22 78 49. Email [email protected]. Categories ...
Model 212B Force ring, 10k lb comp., 18 pC/lb, charge output ...
Model Number 212B Revision: H ECN #: 50221 Performance ENGLISH SI Sensitivity(± 15 %) 18 pC/lb 4,047 pC/kN Measurement Range(Compression) 10,000 lb 44.48 kN
Model 602M64 Industrial 3-Wire Accelerometer Installation and Operating ...
Size (Length x Width x Height) 1.65 in x 0.74 in x 0.845 in 41.9 mm x 18.8 mm x 21.5 mm Weight 2.61 oz 74.0 gm Mounting Thread 1/4-28 Male No Metric Equivalent [5] Mounting Torque 2 to 5 ft-lb 2.7 to 6.8 Nm Sensing Element Ceramic Ceramic Sensing Geometry Shear Shear Housing Material Stainless Steel Stainless Steel Sealing Welded Hermetic ...
Model 628F11 Precision Quartz Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
2X - PCB
5 7 9 / 2 / 2 0 1 5 4 1 3 4 1 PCB Piezotronics Inc. claims proprietary rights in the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others without the written consent of PCB Piezotronics Inc..57 [14.5] 1.76 [44.8].68 [17.3].25 [6.4].40 [10.2]
TJ-120 - Amphenol NEXUS Technologies
Title: TJ-120 : Created Date: 1/9/2004 3:56:18 PM
Model 607A01 Swiveler® Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model M119C12 High pressure ballistic pressure sensor, 100k psi ... - PCB
.200 16.5 20 .50 6.6 50 1.0 3.3 100 Passage Resonance vs. Passage Length Actual resonant frequencies measured in practice may differ slightly from the chart values. These differences are due to variations in the velocity of propagation of sound in air caused by changes in temperature and pressure of the air in the passage. ...
PCB
Created Date: 5/20/2010 3:20:30 PM
Model EX639A91 Industrial Triaxial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
amphenol-antennas.com
Created Date: 5/10/2021 4:04:42 PM
PCB Piezotronics | Measure vibration, pressure, force, and more
Created Date: 5/27/2014 2:10:14 PM
Model M623C01 High Frequency Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 355B12 Miniature (2 gm), ring-style, ceramic shear ICP ... - PCB
Model 355B12 Miniature (2 gm), ring-style, ceramic shear ICP® accel., 10 mV/g, 1 to 10k Installation and Operating Manual For assistance with the operation of this product,
36.5 - Amphenol Sine
36.5 a3 - release new drawing format 27dec13 jarry - refer to sheet 2 for available connector colors 1 notes: unless otherwise specified 1 see sheet 2 for key arrangements and colors. 2. material: housing: thermoplastic seal: silicone rubber 3. modifications: n/a 4. specifications: 4.1 current rating: 13 amps 4.2 operating temperature: -55°c ...
227-1483 - amphenolrf.com
Title: 227-1483.ps Created Date: 5/21/2004 5:31:32 PM
Temposonics
2.5 (0.10) 6.2 (0.24) 16.1 (0.63) 2 (0.08) +0 -0.2 +0 -0.01. 7 Temposonics® E-Series Embedded Analog Installation in a hydraulic cylinder The mounting method is determined exclusively by the cylinder construction (Fig. 5). In most cases, the installation is performed from the side of the piston rod. However, installation from the piston side of