Search Results for biphenol structures
Model 1630-04C - PCB
Failure of the load cell structure may cause personal injury and equipment damage. The load cell can withstand loads of at least 150% of the full-scale capacity before any damage occurs to the sensing element. Be sure that the load cell and any fixturing used is properly designed, fabricated, and securely installed prior to use.
Model 1404-02ADB FATIGUE RATED LOW PROFILE LOAD CELL, DUAL BRIDGE ... - PCB
structure or fasteners used in the load cell installation may cause personal injury and equipment damage. It is important to provide adequate clearances and safety guards or shields properly surrounding test fixtures where fatigue rated load cells are used. It is important to review the manufactured data when selecting
Model 357B61 - PCB
Model 357B61 High temp., ceramic compression, charge output accel., 10 pC/g, 5kHz, 10-32 side conn. (-65F to +900F), supplied with 10-ft hardline cable
CMR Group - Harnessing the energy transition
Harnessing the energy transition. Référence pour les systèmes de câblage et les capteurs pour environnements difficiles dans les secteurs de l'énergie, du rail, de la marine et de la défense.
Model 357B02 High temp., ceramic shear, charge output accel., 15 pC/g ...
Model 357B02 High temp., ceramic shear, charge output accel., 15 pC/g, to 9k Hz, 10-32 top conn. (-95F to +500F) Installation and Operating Manual
Model 357B34 High temp., ceramic shear, charge output accel., 100 pC/g ...
Model 357B34 High temp., ceramic shear, charge output accel., 100 pC/g, 3k Hz, 10-32 top conn. (-95 F to +500 F) Installation and Operating Manual
Model 2302-02A REACTION TORQUE SENSOR Installation and Operating ... - PCB
structures with no moving parts and are typically mounted in a fixed position. Their output signal varies proportionally to an applied torsional force. Capacities range from 5 to 500k in-lb (0.56 to 56.5k N-m). Figure 1 – Flange Mount Reaction Torque Sensor Due to the fact that these sensors do not utilize
Model 357B03 Platinum Stock Products; High temp., ceramic shear, charge ...
Model 357B03 Platinum Stock Products; High temp., ceramic shear, charge output accel., 10 pC/g, 9k Hz, 10-32 side conn.(-95 F to +500 F) Installation and Operating Manual
Model 2508-01A Reaction Torque Sensor Installation and Operating ... - PCB
structures with no moving parts and are typically mounted in a fixed position. Their output signal varies proportionally to an applied torsional force. Capacities range from 5 to 500k in-lb (0.56 to 56.5k N-m). Figure 1 – Flange Mount Reaction Torque Sensor Due to the fact that these sensors do not utilize
Model 357B21 High temp., ceramic shear, charge output accel., 30 pC/g ...
Model 357B21 High temp., ceramic shear, charge output accel., 30 pC/g, 6k Hz, 10-32 side conn.(-95 F to +500 F) Installation and Operating Manual
Model TLD086D50 Large-sledge Impulse Hammer w/force sensor & tips ... - PCB
provide the force amplitude and frequency content required for proper excitation of the structure under test. Large, heavy structures like locomotive frames, tanks and bridges require an instrumented sledgehammer; small structures like compressor blades often require mini-hammers. Some very large
Acheter - Amphenol Socapex
Contacter un vendeur. Etre proche de nos clients est important pour nous. Nous nous assurons que nos commerciaux soient accessibles à tous nos clients internationaux.
Model 340A50 Triaxial, miniature (11 gm) charge output accel., 2. ... - PCB
Biphenyls (PBB) Polybrominated Diphenyl Ethers (PBDE) Housing O O O O O O PCB Board X O O O O O Electrical Connectors O O O O O O ... structure, then securing the sensor to the base. This allows for easy removal of the accelerometer. Also, since the bases are of a “hard-coated” aluminum design,
Model M261B01 Triax force link, ICP®, 1000 lb (Fz), 500 lb (Fx,y ... - PCB
Biphenyls (PBB) Polybrominated Diphenyl Ethers (PBDE) Housing O O O O O O PCB Board X O O O O O Electrical Connectors O O O O O O ... structure with tape, clamps, or adhesives minimizes . cable whip. See Figure 3. 4.0 OPERATION . ICP® force link sensors require a constant-current . ...
Model RHM240A03 Industrial dynamic strain sensor, ICP® quartz ... - PCB
monitored. Strain sensors are mounted to a structure by means of a supplied socket flat head screw, which threads into a corresponding tapped hole, and is then fastened securely as noted in the installation section of this manual. When used with a constant current signal conditioner, the sensor output
Model 357C71 - PCB
Model 357C71 Charge output accel., 10 pC/g, 1000g, to 5 kHz, 2-pin conn., 3- hole mount, to +900 F Installation and Operating Manual For assistance with the operation of this product,
Model M356A70 Triaxial, miniature (8 gm), charge output accel., 2.7 pC ...
Model M356A70 Triaxial, miniature (8 gm), charge output accel., 2.7 pC/g, 5k Hz, (3) 5-44 conn., supplied with M5 X 0.80 cap screw Installation and Operating Manual
Model 105C12 Subminiature ICP® pressure sensor, 1000 psi, 5 mV ... - PCB
electrically to the structure or by using the metal ribbon spotwelded to the sensor body. 3.2 MODELS 105C02, C12 & C22 This style utilizes a 10-32 external thread to facilitate mounting. It is supplied in three full-scale ranges: 100, 1000 and 5000 psi. Prepare mounting port in accordance with installation
Model 357A64 UHT-12™, Charge output accel, high temp to +1200 F, 1 pC/g ...
Model 357A64 UHT-12™, Charge output accel, high temp to +1200 F, 1 pC/g, 1000 g, 0.46 inch cube, stud mount, with screw tabs, to 10k Hz, case isolated
Model 357E92 Charge output accel, with UHT-12™shear sensing ... - PCB
Model 357E92 Charge output accel, with UHT-12™shear sensing crystal, 2.3 pC/g, +1200 F operation, int hardline cable with smaller 10-32 coax Installation and Operating Manual