Search Results for check valve cla-val-81-20
ICP® PRESSURE SENSOR - pcb.com
Excitation Voltage 20 to 30 VDC 20 to 30 VDC Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance ≤ 100 Ohm ≤ 100 Ohm Output Bias Voltage 8 to 14 VDC 8 to 14 VDC Physical Sensing Element Tourmaline Tourmaline Housing Material Stainless Steel Stainless Steel Electrical Connector 10-32 Coaxial Jack 10-32 Coaxial Jack Weight 0.75 ...
TPA/GMT Combination Fuse Panels - Amphenol Broadband Solutions
009-8005-0420 260A 50A/15A ±24, -48 Dual 4/20 2 009-8005-0810 350A 50A/15A ±24, -48 Dual 8/10 2 1) 009-8005-0404J has 200A rated input, continuous at 45°C, 160A continuous at 65°C 2) 009-8005-1404 has bay alarms 3) 009-8005-0404L has 25" depth 4)009-8005-0404LR adds support rails for cabinet installs to the 009-8005-0404L
ValProbe Real-Time Base Station - KAYE
The base station serves as the interface between individual loggers and the powerful ValProbe RT system software. It is used for qualification, calibration, and verification studies.
A A - Amphenol Sine
AT60-20-02XX 3.2 3.5 SECTION A-A A1 -- RELEASE NEW PRODUCT 15/JUL/19 ROOKIE TOMMY 44724 Morley Drive Clinton Township, MI 48036 Sine Systems - www.amphenol-sine.com PROCESS SPECIFICATIONS: MATERIAL SPECIFICATIONS: QUANTITY APPROVAL: ENGINEER: CHECKED: DRAWN: SCALE: PART NUMBER TYPE DWG NO: SHEET OF
Airmar B60-20-MM Transducer for Depth & Temp Sensing - Gemeco
Fixed 20° tilted version for 16 to 24° hull deadrise angles; Fixed 12° tilted version for 8 to 15° hull deadrise angles; Features. Depth and fast-response water temperature sensing; 600 W of power; Dual-frequency element: 50 kHz with a wide 45° beamwidth for depth performance to 353 m (1200')
SENSORS FOR AUTOMOTIVE SAFETY TESTING - pcb.com
0.80 / 0.20: 0.15. 0.30: Frequency response (±5%, Hz) 0-3000 / 0-5000. 0-6000. 0-5000: 0-6000. Shock limit (g pk) 5000 / 10,000. 10,000: Typical Applications. In-dummy crash and : shock measurements. Crash and shock : measurements Crash and sled testing. In-dummy crash and : shock measurements. Passenger safety testing: PIEZORESISTIVE ...
NPI-19 NovaSensor Sensors
± 20% ± 20% ± 20% Environmental Temperature Range Operating(6) Compensation Shock Life (Dynamic Pressure -40°F to 257°F 32°F to 158°F 10 gRMs 100 g 1 x 106 Cycles (-40°C to 125°C) (0°C to 70°C) 20 to 2000 Hz 11 milliseconds Mechanical Weight 0.02 lb (10 g) 0.1 lb (45 g) NPI-19A-XXX NPI-19B/H/J-XXX Media Compatibility All corrosive ...
FAKRA to SMA Cable Assemblies - Amphenol RF
FAKRA Straight Jack to SMA Right Angle Plug LMR-195 50 Ohm 20 Meter Z Key Code 095-820-198M20L. View Details. Add to Parts List Add to Compare. FAKRA Straight Jack to SMA Right Angle Plug LMR-195 50 Ohm 600 Inches Z Key Code 095-820-198-600. View Details. Add to Parts List Add to Compare.
Marine & Industrial Support FAQs - An Amphenol Company
Why would a boat need an Isolation transformer? To create a safer, “off-grid” electrical AC power source inside the boat. This eliminates to possibility “stray current” from nearby boats and eliminates the possibility of AC power leaking into the water.
Amphenol RF
Created Date: 3/22/2012 10:20:34 AM
Model 602D01 | PCB Piezotronics
Model 602D01:Platinum Stock Products; Low profile, industrial, ceramic shear ICP® accel., 100 mV/g, 0.5 to 8000 Hz, side exit, 2-pin connector, single
ARC26-50S02 50 Position Plug, Size 20 Socket Contacts, Jack
ARC26-50S02 50 Position Plug, Size 20 Socket Contacts, Jackscrew, Bonded Front Seal, Keyed 02, Black. Comparable to PN# DRC26-50S02-50 Position Plug, Call Us 1-800-394-7732; My Account; Home; Contact Us; Sign in or Create an Account Shopping Cart (0 Items) $0 0 Items ...
UNIAXIAL STRAIN SENSOR - pcb.com
Sensitivity(± 20 %) 50 mV/µε 50 mV/µε ... 0.67 in x 1.81 in x 0.6 in 17 mm x 46 mm x 15.2 mm Weight 1.6 oz 45 gm [3] [5] All specifications are at room temperature unless otherwise specified. In the interest of constant product improvement, we reserve the right to change specifications without notice. ICP ...
Heavy Duty Cylindrical MIL-C-22992 QWLD - amphenol-aerospace.com
MS17343 R 20 N 27 P W 1 234567 1. MS Number - MS17343 designates wall mount receptacle MS17344 designates straight plug MS17345 designates cable connecting plug ... 81- Crimp type contacts, plated .0001 gold over silver 82- Crimp type contacts for MIL-C-13777 cable, silver plated
TrueDrop Connectors T - cabelcon.com
Page 6 Customer Service D: +45 55 98 55 99 TDC-4-4-Port Feature PushOn force Removal force Remark Regular With/without color ring 40 N 42 N Plating to withstand more than 100
858 series | Amphenol Global Search | Amphenol
This series, is a rapid-mating, general duty, or ruggedized harsh environment, metal push/pull coupling, power, and signal connector. With over 20 insert arrangements ranging from 2 to 12 contacts per connector and up to 23 amps possible with a standard operating temperature from -40°C to +100°C.
Amphenol Assembletech
Applications. 1. Servers 2. Data Storage 3. Workstation 4. Desktops Features and Benefits. 1. Smaller size connector and cable saves device space
FLOS Push-Pull Connector Series - Amphenol Aerospace
• Overmolded with Cable : -20°C ~ 85°C • Field Installable : -40°C ~ 125°C: Fasten Style of Nut: Front & Rear: Front: Front: Front & Rear: Front & Rear: Receptacle Overmolded with Cable Field Installable Accessories Applicable Wire Gauge-----Mating Cycles (Pin Contact) 3,000 Cycles: 3,000 Cycles
Level Plus - Temposonics
Output signal/protocol Modbus RTU, DDA, Analog (4…20 mA), HART® Order length Rigid Pipe: 305 mm (12 in.) to 7620 mm (300 in.) (Order length equals the measurement range plus the inactive zone. Contact factory for longer lengths) Inherent accuracy ±1 mm (0.039 in.)
GS-12-220 rev J - Amphenol CS
GS-20-023: Application Specification, 2mm High Power Connector System GS-20-001: Attachment Specification for Metral Connectors (press peg specification) 4.2 Other Standards and Specifications IEC 664-1: Insulation Coordination for Equipment with Low-Voltage Systems IEC 61984: Connectors - Safety Requirements and Tests