Search Results for ddu remover
Amphenol Pcd
Military Qualified, QPL Listed Relay Socket Part Numbers Military Socket P/N APCD Socket P/N Pg. M12883/40-01 RSL116079 8 M12883/40-02 RSL116081 8 M12883/40-03 RSL116083 8
ePower-lite 5.7mm 2 port Connector - Amphenol Industrial Operations
4 Step 5: Install the Rear Cover (Part 8) and the Rear Grommet (Part 7) in sequence. Step 7: Pull one of the wires to make a misplacement with another wire, then assemble contact assembly (part 3). Step 4: Fold back shielding wires onto the rear shield ring. Step 6: Remove film layer, stripping insulation. Item Cutting Length L3 10.5±0.5mm Mylar Part 7 Part 7
ASSEMBLY INSTRUCTIONS - Amphenol Aerospace
removal of clamp. Locked Position TABLE 1 Unlocked Position Rear Nut Assembly 2. Loosen the rear nut assembly by turning it counter-clockwise until some resistance to turning is left. 2 1/2 turns or .075 minimum space is required. 3. Select the proper contact removal tool. To remove pin contact, align and place tool over exposed pin probe. To ...
V59-DAZ49 | Amphenol Global Search | Amphenol
Search Results for V59-DAZ49. The 0.60mm pitch connector come with a slim form factor design, capable of transmitting high-speed signal up to 64G PAM4/PCIe ® Gen 4/PCIe ® Gen 5/PCIe ® Gen 6, and allowing much greater signal path lengths while maintaining SI performance when compared to conventional pcb routing methods.
L-2035-AE.fm - Amphenol Aerospace
against positive stop on contact, grip wire and simultaneously remove tool, contact and cable. L-2035-AE FSCM 77820 October 2001 21-33121-563 M39029/78-432 * USE THIS DIMENSION ONLY IF SHIELD CRIMP SLEEVE WILL GO OVER THE CABLE JACKET DIA AND THEN FOLLOW TYPE I ASSEMBLY INSTRUCTIONS PART NO. & BIN CODE COAXIAL CABLE ACCOMODATED
Amphenol Network Solutions > 1RU 240A DUAL-FEED, 9/9 TPA/GMT FUSE PANEL
Each of the 240A feeds provide power for up to five GMT and four TPA or breakers output positions. The panel includes removable 1RU TPA fuse holders. These 1RU TPA fuse holders feature an ergonomic front grip for easy removal, sliding top cover to protect the fuse from above, and red alarm plunger to indicate a failed fuse.
SMA Male Termination 8018-6005 - SV Microwave
SV Microwave designed the SMA Male Termination 8018-6005 for various electrical, mechanical and environmental performance. Explore now!
MDCU Installation Guide - Amphenol Antenna Solutions
Remove the protective cap on the MDCU AISG male connector and attach the control cable. This cable is coming from an MHA or a Smart Bias-T if the control signals are carried by the coaxial feeder or, if not, it comes directly from the AISG controller, whether included or not into the base station.
MultiMate Series - Amphenol Sine
Trunk (Size 12, 25A Max) and Drop (Size 16, 13A Max) Trunk (Size 16, 13A Max) and Drop (Size 16, 13A Max) Amphenol Sine Systems’ MultiMate™ expands upon the proven reliability of the AT/ATP Series™ environmentally-sealed, IP67/68/69K rated (mated), thermoplastic connection system with rugged over-molded “Plug & Play” connection types for power, signal and data for your diverse ...
696-900 / 696-900 MHz - Amphenol Antenna Solutions
Do not remove the transparent cap(s) from the antenna. Remote Electrical Tilt (RET) Control The remote control of the electrical tilt is managed by a Multi-Device Control Unit (MDCU) inserted in the bottom of the antenna. A single module individually controls the tilt of each band (no need for daisy chain cables between the bands).
AHDP06-24-47SR-SRA 47 Position Plug, Socket, Shell Size 24, - Amphenol Sine
AT11-310-1605 Contact Removal Tool, plastic, Size 16. Comparable to PN# 0411-310-1605. REQUEST A QUOTE. AT13-204-2005 Seal Plug, White, Size 20. Comparable to PN# 0413-204-2005. REQUEST A QUOTE. AT14-001-2486 Metal Lock Washer, Size 24. Comparable to PN# 2414-001-2486. REQUEST A QUOTE.
FME Adapters - RF Coaxial Adapters - Amphenol RF
Amphenol RF offers a full range of FME Adapters designed for radio frequency applications. FME Adapters feature all industry standard connector interfaces in between-series and in-series designs.
50-54931-2 Extraction Tool - Remove 2.0mm Contact from Inserts
50-54931-2 Extraction Tool - Remove 2.0mm Contact from Inserts-Extraction tool. Used for removal of 2.0mm contacts from inserts. Call Us 1-800-394-7732; My Account; Home; Contact Us; Sign in or Create an Account Shopping Cart (0 Items) $0 0 Items ...
Pre-Tinned (De-Golded) PCB Connectors - SV Microwave
for gold removal in the design stage, modifying the connector body so it can be fixtured effectively and gold can be thoroughly removed from the solderable area - including nearby areas which may be prone to capillary effect wicking. Pre-Tinned (De-Golded) PCB Connectors Applications • Military and Aerospace Radar Transmit/Receive Units
21-33387-71 (PIN) 21-33388-71 (SOCKET) - Amphenol Aerospace
Remove piggyback grommet seal from the connector grommet. Position removal tool part number MILI81969/1412, Daniels DRK2648, around cable and slide tool toward connector until tool tips enter rear grommet and comes to a positive stop on the contact. Grip cable and si multaneously remove tool, contact and cable. Amphenol Amphenol ...
Magnetostrictive Liquid Level Transmitters with ... - Temposonics
9. Remove data lines. 10. Install the transmitter into the vessel (see Operation Manual). 11. Reconnect power and data lines. 12. Calibrate current tank level using setup software (optional). 13. Verify communications with the host system. Default communication parameters DDA: 4800 BAUD 8, E, 1 6. Display Menu
AHDM04-24-16PN Receptacle, shell size 24, 16 positions, pin - Amphenol Sine
AT11-337-1205 Contact Removal Tool, plastic Size 12. REQUEST A QUOTE. AT60-12-0144 - Stamped & Formed Gold-Plated Male Contact, Size 12. Comparable to PN# 1060-12-0144. REQUEST A QUOTE. AT60-12-0166 - Stamped & Formed Nickel-Plated Male Contact, Size 12. Comparable to PN# 1060-12-0166.
20200110,Amphenol ACC Stripping Tool Table
Foam remover AFBXD07‐4 Measuring ruler AFBXD06‐3 1/2" Annular trilogy air dielectric (plenum), Trilogy AP6012J50, APC012J50 Spacer 4 Trimming tool AFBXD05‐3 Foam remover AFBXD07‐12 Measuring ruler AFBXD06‐5 Cap AFBXD06‐2 7/8" Foam dielectric, corrugated Spacer 5 Trimming tool AFBXD05 41
AHDP06-24-91SR16-STA 9 Position Plug, Socket, ISOBUS, Shel - Amphenol Sine
AT11-310-1605 Contact Removal Tool, plastic, Size 16. Comparable to PN# 0411-310-1605. REQUEST A QUOTE. AT11-337-1205 Contact Removal Tool, plastic Size 12. REQUEST A QUOTE. AT114008 Contact removal tool, Size 8, 8-10 AWG. Comparable to PN# 114008. REQUEST A QUOTE.
L-1253-AG.fm - Amphenol Aerospace
die set positioner contact removal m22520/5-105 or amphenol® 11-12101 or daniels y631 m22520/2-37 or amphenol® 11-12102 or daniels k709 daniels drk 264-8 5 crimp rear intermediate contact wire well to white wire rear intermediate contact 6 after crimping outer contact, position preformed seal at base of chamfer on outer contact and heat ...