Search Results for difrent types of wire diagrams
Understanding Vibration Switches - PCB
Types of Vibration Switches - There are two basic types of vibration switches: mechanical and electronic, Figures 2 and 3. However, with today’s microprocessor technology, electronic vibration switches can be further subdivided into two types, traditional electronic and programmable electronic vibration switches.
Magnetostrictive Liquid Level Transmitters with Temposonics
Type of protection based on enclosure in which the parts which can ignite an explosive gas atmosphere are placed within, and which can withstand the pressure developed during an internal explosion of an ex-plosive mixture, and which prevents the transmission of the explosion to the explosive gas atmosphere surrounding the enclosure. F Flameproof
mil-c-5015 | Amphenol Global Search | Amphenol
TPC Wire & Cable offers molded and mechanical backshells for MIL-C-5015 circular connectors, which are designed to operate in harsh environments. See technical specifications, applications, and contact layouts for MIL-C-5015 connectors. ... Learn about the different types, features and applications of MIL-DTL-5015 connectors, such as Boeing ...
Fluid-Trac 3-Wire Level Sensor
Epqshiu & . %% Ufdiopmphft. NNE 4 Fpd0 HU/CP Tfw0 & i-rcom Note: The Fluid-Trac® 3-wire level sensor comes with an integral gasket that must be used when mounting. Mating connector parts and bolts are not included. A mating connector kit P/N is available. Note: Gasoline range is different due to the density of gasoline vapors.Gasoline vapors are denser as
Technically Speaking | How Does a Moisture Meter Work? - Protimeter
Pin-Type Meters . Most digital pin-type meters come with a calibration device (aka – a moisture content standard (MCS)) designed for the meter to measure the electrical resistance between its probes. To check the calibration of your pin-type meter, touch its pins to the MCS’s contact points and wait a few seconds.
TECHNICAL NOTE TN-17 - PCB
power source over a two-wire circuit with signal/power carried over one wire and the other wire serving as ground. The cable can be ordinary coaxial or ribbon wire. Low-noise cable is not required. Constant current to operate the accelerometer comes from a separate power unit or it may be incorporated inside a readout
Vibration sensor wiring and cabling - Wilcoxon Sensing Technologies
After the sensors have been properly mounted, installation wiring can be accomplished. This technical note will address the issues involved in proper sensor wiring for permanently mounted sensors. After wiring installation, verification of operation and troubleshooting the installation may be necessary to complete the process. Refer to the Wilcoxon
A Guide to Audio Connectors - Amphenol NEXUS Technologies
Types of Audio Connectors From Amphenol NEXUS Technologies. There are numerous types of audio connectors available on the market to fulfill various needs. One of the more common varieties is the stereo minijack, or headphone jack, connector that has applications in phones and portable music players for listening to music through a headset.
Introduction to Pellistor Gas Sensors - SGX Sensortech
To detect these gas types there are two types of pellistor, Catalytic and Thermal Conductivity (TC), operating in different modes. The catalytic type sensor works by burning the target gas; the heat generated producing a change in the resistance of the ... The earliest form of catalytic gas sensor used heated bare coils of platinum wire to burn ...
Introduction to Piezoelectric Accelerometers - PCB
All PCB ® ICP ® accelerometers require power from a constant current DC voltage source. PCB ® offers different types of ICP ® signal conditioners that provide 2 to 20 mA of current at a DC voltage level of +18 to +30 volts. Do not attempt to power ICP ® sensors with commercially available power supplies. The unregulated current will damage and destroy internal electronics.
n20 252 4051c | Amphenol Global Search | Amphenol
n02 252 4501c | Amphenol Global Search | Amphenol. Suitable for surface temperature measurement. Sensing element electrically isolated from tag. Two standard resistance values: 10 kW & 20 kW nominal at 77°F (25°C) Eyelets to fit M3, M4 & M5 screw sizes. Range of wire lengths 1.97 in to 78.74 in (50 mm to 2000 mm) (dimension WL in diagram on ...
10182 | Amphenol Global Search | Amphenol
Airmar's transducer cross reference offers a variety of transducer information—from wiring diagrams and more. Just enter the first few numbers of the part number and see the results immediately. ... a type of connector used in military and industrial applications. See specifications, dimensions, catalog s, and links for different models and ...
Downloads - Lutze Inc.
Cabinet Wiring with the energy efficient and space saving AirSTREAM system, LSC Cabinet Wiring Control Power supplies, Relays, Switching Devices, Signal Converters, Wiring Protection, Monitoring Relays, Ethernet Infrastructure, Function Modules and Accessories
Pellistor Application Note 1 Pellistor Sensor Technology & Applications
They can also be used to detect gases whose thermal conductivities are significantly different to that of air, e.g. helium. This mode is known as the thermal conductivity mode. In this case, the gas can be measured up to 100% volume. DESCRIPTION The catalytic sensor consists of a coil of a small diameter platinum wire supported in a refractory ...
Temposonics
Wiring of 10-0 V and 20-4(0) mA outputs is valid for LD sensors from fabrication # (F-No.) 0546 xxxx. Typical Grounding Cable shield and DC Ground have to be isolated separately! Typical 4 - 20 mA wiring Front view male insert All dimensions in mm Front view male insert
n02 252 0064c | Amphenol Global Search | Amphenol
Amphenol RF offers a full range of N-Type Adapters designed for radio frequency applications. N-Type Adapters feature all industry standard connector interfaces in between-series and in-series designs. ... Eyelets to fit M3, M4 & M5 screw sizes. Range of wire lengths 1.97 in to 78.74 in (50 mm to 2000 mm) (dimension WL in diagram on page 2 ...
Amphenol
solder a smaller wire to a larger con-tact. However, soldering a large wire to a small contact isn’t recommended because of size and current require-ments. What if several identical. connectors have different functions? Here’s a situation to watch out for. You have four identical receptacles . on a panel. One carries high current loads.
Absolute, Non-Contact Position Sensors Operating Manual MH Series ...
Wire color 12/24 VDC BN GND (OV) WH Signal GN Wire assignment PUR-cable Wire color 12/24 VDC BN GND (OV) WH Signal GN 4. Electrical connection Temposonics® MH series sensors are equipped with an M12 connector. For electrical wiring pin assignment has to be checked. Optionally, the sensors are available with single wire or PUR cable outlet.
Product Data Sheet - Temposonics
WIRING Connection type: 6-pin male D60 (M16) connector or integral cable ... Single and dual-magnet output diagram When using dual magnets, the minimum allowed distance between the magnets is 75 mm (3 in.) to maintain proper sensor output. ... There are six different manufactur-ing build types available, three single channel and three dual ...
SMPM Product Series Solutions Guide Catalog - Amphenol RF
Connector Body Types Straight Jacks with Male Contact – Full Detent Part Number Packaging Type Body Mount Max Frequency (GHz) Image 925-126J-51P Individual Bag End Launch 40 925-138J-51P Individual Bag Through Hole 40 925-143J-51P Individual Bag Surface Mount 10 925-143J-51PT Tape & Reel Surface Mount 10 925-196J-51PT Tape & Reel Surface ...