Search Results for dimmer ac arduino
ePower-Lite Mini
3 Step 2: Strip out ALU-PET foil, evenly disperse and bend the shielding net, ensure the inner ferrule is in close contact with shielding wire. Step 3: Assemble the outer ferrule and crimping to right crimp height (7.5±0.1 mm), cutting and the jacket. Step 4: Stripping the jacket and cut off the exposed shielding wire of cable, crimping the terminal by right crimping tool.
AC-HDMI-RRB | Amphenol Global Search | Amphenol
It accepts an AC input range from 85 to 265VAC, 50/60/400Hz and provides a single DC output from 3.3V to 48V, up to 300W, with custom outputs available. Designed to meet military standards MIL-STD-704, MIL-STD-1399, MILSTD-810, MIL-STD-461.
M1326103 Series | AC-DC Power Supplies | Power Supplies | Products ...
The M1326103 Series military power supply is a rugged AC to DC converter. It accepts an AC input range from 85 to 265VAC, 50/60/400Hz and provides a single DC output from 3.3V to 300V, up to 1000W, with custom outputs available.
Connectors - Amphenol CS
Amphenol has developed a product series of MiniStak high-density and high-speed board-to-board connectors... HIGHEST DENSITY CARD EDGE SERIES The NEW 3000W EnergyEdge™ X-treme Card Edge series offers the... Our Right Angle Standard Speed line of modular jacks (< 1Gb/s) are Cat3 and Cat5 compliant. All modular...
termination-instructions-sae-circular-gt-series-amphenol-industrial
Amphenol, SAE AS50151, AC Threaded, ACA Reverse Bayonet and GT Reverse Bayonet incorporate MIL-STD-1651 insert arrangements as well as some special arrangements. Crimp type contacts in size 4/0,1/0,0,4,8,12,16 and 16S are available for use in these insert arrangements.
DIN RAIL MOUNT ICP® SIGNAL CONDITIONER - PCB
a choice of AC or DC coupling and a high frequency response, both quasi-static and dynamic measurements up to 10 kHz are possible. The unit synchronizes with machine cycles through a reset feature while analog and peak hold outputs allow for real-time monitoring with machine control devices. Requires a
Model 441A101 MODULAR AC LINE POWER SUPPLY Installation and ... - PCB
Two rear panel fuses, located below switch in the AC receptacle, protect the power line inputs of the instrument. The fuse type is a T 1.6A, L 250 V. To change the fuse, disconnect the power cord. Find the slot just above the power switch and pull forward to open the door that exposes the fuse drawers. Pull the individual drawer
WIRING DIAGRAM 120 OHMS 1/2 WATT FACE VIEW
milliamps current leakage @ 1500 volts ac. 3.4 insulation resistance: 1000 megohms min @ 25°c. 3.5 moisture resistance: ip67 ( mated condition ) 3.6 mating cycle durability: 100 cycles 3.7 rohs compliant 4. resistor specifications:120 ohms. 5. mating part: atm04-2p* receptacle ( * = modifications and colors ) 6. all dimensions are for ...
C:UsersROrmanDesktop$ drawingsC-04410310001 REV A1 - Amphenol Sine
MATERIAL: THERMOPLASTIC ELASTOMER COLOR:BLACK. SPECIFICATIONS: 2.1 CURRENT RATING: 8 AMPS. 2.2 RATED VOLTAGE: 250V AC/DC. 2.3 OPERATING TEMPERATURE: -40°C TO +105°C. 2.4 DIELECTRIC WITHSTANDING VOLTAGE: LESS THAN 2 MILLIAMPS CURRENT LEAKAGE @ 1500 VOLTS AC. 2.5 INSULATION RESISTANCE: 5000 MEGOHMS MIN @ 25°C.
Amphenol
milliamps current leakage @ 1500 volts ac. 3.4 insulation resistance: 1000 megohms min @ 25°c. 3.5 moisture resistance: ip68(im of water for a period of 24 hours,mated condition); ip69k (mated condition) 3.6 mating cycle durability: 100 cycles 3.7 rohs compliant 4. mating part: athd06-1-12s-xx plug (xx = modifications) 5.
Amphenol Network Solutions > Store > Products > Power > AC Power Panels
22425 East Appleway Ave #11 Liberty Lake, WA 99019 Phone: 509.926.6000 Email: getinfo@amphenol-ns.com
Mini-SAS HD Internal Connectors – G40H Series - Amphenol CS
Amphenol Mini-SAS High Density connector system is the next generation SAS system that provides faster data rates and more bandwidth. It provides double the port density of current Mini-SAS connectors with 1x1, 1x2 and 1x4 port options. Mating Force: 50N max. Unmating Force: 10N max. Voltage Rating: 30V AC/ DC max.
PA-USB_485-2 - Amphenol Antenna Solutions
No external power supply is necessary to power the unit – simply plug it directly into an AC socket using a standard power cord to power it up. The communication with the PC is provided by a simple connection to any USB port available. Be sure to install the driver before connecting the PA-USB-485-2 to your computer.
Model 3711F1150G Platinum Stock Products; Single Axis MEMS DC ... - PCB
Model 3711F1150G Platinum Stock Products; Single Axis MEMS DC accelerometer, 27 mV/g, 50g, 1/4-28 4-Pin Plug Installation and Operating Manual For assistance with the operation of this product,
UE27AC5410H | USB 2.0 CONN (Type A and B) | Amphenol
Amphenol is one of the leading manufacturers of Input Output Connectors. Contact us today for more details of USB 2.0 CONN (Type A and B) Part Number, UE27AC5410H.
Model 3713F1150G Platinum Stock Products; Triaxial MEMS DC ... - PCB
DC accel-erometers via an adhesive mounting base. The base acts as a sacrificial part. allowing safe removal of accelerometer after te. he de-bonding agent has softened the adhesive, use a gen-tle shearing (or twisting) motion to remove the base and/or.
C:Userssullen.zhangDesktopLED CUSTOMER DRAWINGSC-AT06-2S-LED24XX-A2
LASER ENGRAVE POLARITY, CONTACT NUMBER, VOLTAGE, SEAL TYPE, AND LED COLOR CODE AS SHOWN IN THIS AREA. SEE PART NUMBER CHART BELOW. YYY = LED COLOR CODE. XX = SEAL CODE. RD IF REDUCED DIA., MATERIAL: HOUSING: THERMOPLASTIC; BLACK SEAL: SILICONE RUBBER. MODIFICATIONS: LIGHT EMITTING DIODE; STRAIN RELIEF END CAP OPTIONAL REDUCED DIAMETER SEAL
Understanding the Endevco Variable Capacitance Accelerometer Electrical ...
Endevco VC accelerometers are ideally suited for operation with piezoresistive bridge signal conditioners found in many modern data acquisition systems. When using these accelerometers with a bridge signal conditioner, 10 Vdc excitation should be selected.
Model 482A22 4-channel, line-powered, ICP® sensor signal cond ... - PCB
The AC signal information is decoupled from the sensor bias by a coupling capacitor and brought out to the OUTPUT jack. The bias monitor consists of a color-coded front panel meter and a four position selector switch.