Search Results for distance measuring tool
Modally Tuned® Impact Hammers | PCB Piezotronics
3425 Walden Avenue Depew, NY 14043. Sensorline SM 716.684.0001. info@pcb.com +1 800-828-8840
Model 010M160/002 | PCB Piezotronics (en)
3425 Walden Avenue Depew, NY 14043. Sensorline SM 716.684.0001. info@pcb.com +1 800-828-8840
Cables & Adapters - airmar-emea.com
Marine Transducers. Chirp-Ready Transducers; NMEA/SMART Transducers; Traditional Frequency Transducers; Speed & Temperature; Multi-Beam Transducers; Transducer Diagnostic Tester
PC420VP-50 Vibration transmitter, velocity, peak, 5.0 in/sec
Vibration transmitter, 4-20 mA output proportional to peak velocity vibration, 5.0 in/sec full-scale measurement range, ±5% tolerance at full scale, operates up to 105°C, top exit 2-pin MIL-C-5015-style connector
Model 080M233 | PCB Piezotronics
Model 080M233:Hermetic feed thru adapter, 4-pin jack to 4-pin jack
Model VIBROMET500V-R | PCB Piezotronics (en)
3425 Walden Avenue Depew, NY 14043. Sensorline SM 716.684.0001. info@pcb.com +1 800-828-8840
Model 354A05 | PCB Piezotronics (en)
3425 Walden Avenue Depew, NY 14043. Sensorline SM 716.684.0001. info@pcb.com +1 800-828-8840
Model 9155d-405 | PCB Piezotronics
ICP SUT Signal Conditioner Option for Model 9155 Calibration System. Includes PCB Model 482C05 single channel unity gain signal conditioning and 422 series in-line charge amplifier.
CW and Programmable Sweep Transmitter | 100 MHz - PCTEL
Frequency Range: 100 MHz – 2.5 GHz (usable down to 80 MHz) Frequency Resolution < 1 Hz: Output Power-40 dBm to +10 dBm: Timebase: Accuracy (excluding temperature drift): ± 5 ppm / year
nu 1008 bearing | Amphenol Global Search | Amphenol
67 Series. Operating temperatures from -67 °F (-55 °C) to 257 °F (125 °C) per MIL-C-5015; Sealed connectors capable of 1500 VRMS at 70,000 ft. altitude
Model 102B14 | PCB Piezotronics
Model 102B14:Cryogenic ICP® pressure sensor, 5000 psi, 1 mV/psi, 3/8-24 mtg thd, ground isolated with safety wire holes
Placebo Transducers | PCB Piezotronics
Placebo Transducers A Tool for Data Validation. For any testing in which the environmental operating conditions of a transducer vary with time and/or location, several requirements must be fulfilled before measurement uncertainty analysis is justified.
Cryogenic ICP® Accelerometers | PCB Piezotronics
Spot Face Tools; Motor Fin Mounts; Data Collector Poles; ICP Signal Conditioners; Studs & Through Bolts; Portable Vibration Calibration; Applications. Test and Measurement. ... Measurement Range: ±150 g pk; Measurement Range: ±1472 m/s² pk; Broadband Resolution: 0.01 g rms; Broadband Resolution: 0.1 m/s² rms;
P66 50/200kHz, 600W, Raymarine, DST - airmar-emea.com
600 W. The P66S TRIDUCER ® Multisensor combines depth, speed, and temperature functions in one housing. And it features our 50/200 kHz, dual-frequency, ceramic element. This hydrodynamic housing with its rounded nose reduces the turbulence under the transducer’s acoustic face for accurate high-speed readings and clear display images.
Model 353B51 | PCB Piezotronics (en)
3425 Walden Avenue Depew, NY 14043. Sensorline SM 716.684.0001. info@pcb.com +1 800-828-8840
Seismic Sensors for Infrastructure Testing and Monitoring
Choose PCB® seismic sensors to measure confidently PCB® sensors for infrastructure testing and monitoring are used by design engineers worldwide. We have thousands of seismic vibration sensors in stock, ready to ship, with lifetime warranty.
Model 010D05 | PCB Piezotronics
Model 010D05:4-conductor, shielded, FEP cable, 5-ft, 4-socket plug to 4-socket plug
Model 027137-04022 | PCB Piezotronics (en)
3425 Walden Avenue Depew, NY 14043. Sensorline SM 716.684.0001. info@pcb.com +1 800-828-8840
AR-86 Transverse Sensitivity - PCB
As in any measurement of sensitivity to an input, uncertainties in the input source should be much smaller than the desired combined uncertainty. To accurately measure 1% crosstalk, the goal was to create a shaker system which would introduce less than 0.1% transverse motion (Axy / Az < 0.001).
Model 010D10 | PCB Piezotronics
Model 010D10:4-conductor, shielded, FEP cable, 10-ft, 4-socket plug to 4-socket plug