Search Results for emi emc
M2803 Series - amphenol-aerospace.com
EMC: Designed to meet* MIL-STD-461F: CS101, CS114, CS115, CS116, RE102, RS103 with external filter and shielded cable. Isolation: 1000 VDC between Input and Output 1000 VDC between Input and Case Meets or exceeds MIL-STD-810G Temperature: Operating –55°C to +85°C (at baseplate) Storage –55°C to +125°C ENVIRONMENTAL CONDITIONS:
amphe-lite-subminiature-connectors-catalog-amphenol-industrial
Amphenol® Amphe-Lite connectors provide EMI shielding capability which exceeds MIL-DTL-38999 Series III requirements. The Amphe-Lite connector with EMI grounding fingers and conductive finishes has proven to be the ultimate in EMI shielding effectiveness. The charts at right illustrate shielding effectiveness
Data Sheet R-Series Rod Model RF - Temposonics
Standards, EMC test Electromagnetic emission EN 61000-6-4 Electromagnetic immunity EN 61000-6-2 EN 61000-4-2/3/4/6, Level 3/4, Criterium A, CE qualified1 Design, Material Diagnostic display LEDs beside connector Sensor electronics housing Aluminum Sensor stroke Stainless steel conduct with Teflon® coating Position magnet Ring- or U-magnet
Temposonics
EMC test Electromagnetic emission according to EN 55011, cl. B:2009 + A1:2010 Electromagnetic immunity according to EN 61326-1:2006 The sensor meets the requirements of the EC directives and is marked with . Magnet movement velocity Any Design/Material Sensor electronics housing Stainless steel 1.4305 (AISI 303)
2009 e BA EtherCAT - Temposonics®
the-art. The sensors meet the European Guideline 89/336/EEC (91/386/EEC, 93/44/EEC) and comply with the EMC standards for electromagnetic emission EN 50081-1and electromagnetic immunity EN 50082-2. Risks for the user or a third party can, however, arise during operation and damage can occur to the sensor or other objects. TEMPOSONICS Sensors
GENERATION - Temposonics
EMC test Electromagnetic emission according to EN 61000-6-3 Electromagnetic immunity according to EN 61000-6-2 The sensor meets the requirements of the EC directives and is marked with . Operating pressure 350 bar (5,076 psi)/700 bar (10,153 psi) peak (at 10 × 1 min) for sensor rod/RH5-J: 800 bar (11,603 psi) Magnet movement velocity Any
Data Sheet R-Series V RDV Analog - Temposonics
EMC test Electromagnetic emission according to EN 61000-6-3 Electromagnetic immunity according to EN 61000-6-2 The RDV sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 No. 1091 and
2M Hermetic Micro-Miniature Connectors - Amphenol Aerospace
If you have any specific requirements, such as electromagnetic compatibility (EMC) filters or printed circuit board (PCB) mounting, make sure they are included in your design specification. What are your plating requirements? We offer a wide range of in-house plating options, including tin, nickel, and hard and soft gold. We can also customize ...
hv connectors | Amphenol Global Search | Amphenol
ASRC HV series connectors are high voltage and high current heavy rectangular connectors. Up to 700A per contact and voltages up to 4000V. A wide range of inserts for signal and power transmission. The robust metal housing offers excellent EMC ratings and guarantees IP68/IP69K leakage proof.
Amphenol Filtered Connectors - アンフェノールジャパン ...
ture of filter connectors and has been pioneering EMI and EMP technologies for more than 40 years. Located in Toronto, Canada, our modern 60,000 sq. ft. facility employs approximately 250 people, and is dedicated to the manufacture of filter connectors. We design, develop and manufacture EMI and EMP filter
M7027 SERIES - amphenol-aerospace.com
• EMI filters included • Remote sense compensation • Parallel connection option • Remote sense compensation ... EMC: Design to Meet* MIL-STD-461F CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101, RS103 Output Voltage Regulation: Up to ±1% (no load to full load, –55°C to
Data Sheet E-Series ER Analog - temposonics.com
EMC test Electromagnetic emission according to EN 61000-6-3 Electromagnetic immunity according to EN 61000-6-2 The ER sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 Nr. 1091 and TR ZU 020/2011 Magnet movement velocity ≤ 5 m/s Design/Material Sensor electronics housing Aluminum Guided driving rod Aluminum
Temposonics MH-Series MH4 Plus Analog 551958
EMC Compliant with: ISO 13766-1:2018 Earth-moving and building construction machinery EN ISO 14982:2009 Agricultural and Forestry Machinery EN 13309:2010 Construction machinery ISO 16750-2:2012 Road vehicles EMI 200 V/m (ISO 11452-2:2019 200…2000 MHz) 200 mA (ISO 11452-4:2011 20…200 MHz)
Temposonics
EMC test Electromagnetic emission according to EN 61000-6-4 Electromagnetic immunity according to EN 61000-6-2 The sensor meets the requirements of the EU directives and is marked with Operating pressure 350 bar (5,076 psi), 700 bar (10,153 psi) peak (at 10 × 1 min), GB-J: 800 bar (11,603 psi) Magnet movement velocity Any Design / Material
M916 Series - amphenol-aerospace.com
EMC Designed to meet* MIL-STD-461F CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101, RS103 Turn on Transient No output voltage overshoot during power on. HOW TO ORDER PART NUMBER Input Output J2 Pinout Voltage range Voltage Current CF-02EM916 85 to 265 VAC, 50/60/400 Hz, 1-phase 3.3 VDC 35 A LV option
Amphenol Industrial Operations
Amphenol Industrial Operations
Product Data Sheet - Temposonics
EMC test: Electromagnetic emission: IEC/EN 50081-1 Electromagnetic susceptibility: IEC/EN 50082-2, IEC/EN 61000-4-2/3/4/6, ... to ensure EMI protection for unsurpassed reliability and operating safety. * UL Recognition requires an approved power supply with energy limitation UL 61010- 1), or Class 2 rating according to the National Electrical ...
DECLARATION OF CONFORMITY (DoC) No. XXXX - Adronics
Part 2, Chapter 1, 6.1(b) EMC Standards: • EN 301 489-3 v2.3.2:2023-01 • EN 55032:2015 +A11:2020 • EN 55035:2017 +A11:2020 The Radio Equipment Regulations. Part 2, Chapter 1, 6.2 Radio Standards: ... an adequate level of electromagnetic compatibility . Regulation 6.2: effectively uses radio spectrum . Signed for and on behalf of: Place of ...
Operation Manual TempoLink Smart Assistant - Temposonics
• are competent in the field of electromagnetic compatibility (EMC) or • have received adequate training for commissioning and service operations • and are familiar with the operation of the device and know the information required for correct operation provided in the product documentation NOTICE 2.1 Intended use
EU Declaration of Conformity - AMPHENOL PROCOM
Electromagnetic Compatibility (EMC) Directive 2014/30/EU EN 301 489-1 v1.9.2 Electromagnetic Compatibility (EMC) standard for radio Equipment and services; Part 1: Common technical requirements Chapter 9.2: Radio frequency electromagnetic field Chapter 9.3: Electrostatic discharge RoHS Directive 2011/65/EU and amending directive (EU)2015/863