Search Results for ex series
Temposonics® E-Series EP/EL Position Sensors
E-Series EP/EL. Compact profile design for applications with limited spaces. Ultra low designs for external mounting; Multi-position measurement up to 8 magnets; Outputs: Analog, CANbus, IO-Link, SSI, Start/Stop; Specifications; Documents & Downloads; Certifications & Approvals; Output
CERTIFICATE OF COMPLIANCE
QPS Evaluation Services Inc Testing, Certification and Field Evaluation Body Accredited in Canada, the USA, and Internationally Page 2 of 2 File
Vibration monitoring considerations in high EMI environments
Condition monitoring can detect premature failure and ex-tend the life of the machine. Rotating machinery critical to the process chain including AC/DC motors, turbines, fractional horsepower motors, VFD controllers, SCR controllers, and generator exciters should be continuously ... sensors were subjected to a series of shock pulses up to 8,500 ...
Model 608M50 Industrial 3-Wire Accelerometer Installation and ... - PCB
• 603 Series (XX)603yzzz1aaa EX - Approved for Hazardous Locations • 606 Series (XX)606yzzz/aaa M - Metric Mounting Hardware o 607 Series (XX)607yzzz/aaa TO - Dual Output (Vibration/Temperature) 608 Series (XX)608yzzz/aaa Note: "yzzz" completes the model, "aaa" indicates cable length (if applicable)
CONEC Company Profile - CONEC
You may enter any portion of a part number with a minimum of three characters (ex: 242A, 3W3C). Enter full part number to target results. (ex: 242A24180X, 3W3C) If you do not obtain the desired results, try searching again by omitting the suffix and searching product family. Search results are sorted by part number and upload date.
Operation Manual Level Plus DDA Interface - Temposonics
the display on the LP Series. Note: Improper use of the Stylus can cause the display to not function properly. 6.1 Operation Modes The LP Series level transmitter runs in one of the following modes of operation. You can use these modes to calibrate and set up various operating parameters. 6.1.1 Run Mode Run mode is the primary mode of operation.
Magnetostrictive Liquid Level Transmitters with Temposonics Technology
All LP-Series liquid level transmitters are shipped with a Stylus (MTS Part # 254740) to be used for manipulating the display. For single and dual cavity housings, the Stylus is designed to allow for programming of the unit without removing the housing. When using the Stylus make sure to align the Stylus with the shape outline around the buttons in
MIL-DTL-38999 Connectors - Amphenol Aerospace
Series Series Series Military. 4 Contact Amphenol Aerospace for more information at 800-678-0141 • www.amphenol-aerospace.com 38999 III T II 16 I II Access Auacon MIL-DTL-27599 Crimp Hermetics Service Rating Total Contact Size JT II LJT I TV III III JT/LJT Solder H Y TV* 23 HD 22D 22M 22 20 16 16 (Cx) 12 12
Model EX649A71 | PCB Piezotronics
For use with 070A103 dongle to program 649-Series devices. About PCB ® PCB ® manufactures sensors used by design engineers and predictive maintenance professionals to test and measure vibration, pressure, force, acoustics, load, and shock in research and development as well as industrial applications.
Data Sheet GTE Analog - Temposonics
The Temposonics® G-Series redundant GTE sensors provide precise, linear position measurement for applications where redundancy ... Ex tc IIC T130 °C Dc –20 °C ≤ Ta ≤ +75 °C (−4 °F ≤ Ta ≤ +167 °F) CERTIFICATIONS Fig. 3: Certifications GTE Analog TECHNICAL DRAWING GTE Analog agne 3.4
PC420VP-30-EX Explosion-proof vibration transmitter, velocity, peak, 3. ...
Model PC420VP-30-EX Explosion-proof vibration transmitter, 4-20 mA output proportional to peak velocity, 3.0 in/sec full-scale measurement range, ±5% sensitivity tolerance at full scale, certified Explosion Proof for use in hazardous locations
MAC800-IS intrinsically safe handheld vibration meter
MAC800-IS intrinsically safe handheld vibration meter Model: MAC800-IS. The MAC800-IS supplies all the functionality of Wilcoxon's MAC800 meter, with built-in filter bands and a display color-coded to ISO 10816-3 alarm levels, and offers the added benefit of hazardous area approvals.
Intrinsically Safe vibration transmitter, velocity, RMS, 3.0 in/sec
Intrinsically safe vibration transmitter, 4-20 mA output proportional to RMS velocity vibration, 3.0 in/sec full-scale measurement range, ±5% tolerance at full scale, operates up to 85°C, top exit 2-pin MIL-C-5015 style connector, certified for use in Class I Division 1 and Zone 0 / Zone 1 hazardous locations
All Products | Products | Amphenol
The HDE series is a HAZLOC EX Class 1, Div 1, and Zone 1 rated connector system for the most extreme hazardous locations. This product line is intermateable with the Pyle National AF/GD connectors. AEx Class I, Div 1 Gr BCD, T5-T6 Ex db IIC, T5-T6 Gb Explosion-Proof UL1203 and CSA C22.2 No. 30-M1986 Flame-Proof UL/ EN/ CSA C22.2 60079-1 ...
Certificate of Compliance
A-Z for EX602 series A-Z for EX603 series A-Z for EX606 series A-Z for EX607 and EX608 series d = any numeric digit denoting connector style or integral cable ... 1 A/Ex ia IIC for all EXTO models indicated on the original report 1469131. Model No: EXab607cde and EXab608cde and ab608cde with
Intrinsically Safe vibration transmitter, acceleration, peak, 10 g
Intrinsically safe vibration transmitter, 4-20 mA output proportional to peak acceleration vibration, 10 g full-scale measurement range, ±5% tolerance at full scale, and operation up to 85°C, top exit 2-pin MIL-C-5015 style connector, certified for use in Class I Division 1 and Zone 0 / Zone 1 hazardous locations
CONEC SnapLock D-SUB Hoods & Connectors - CONEC
You may enter any portion of a part number with a minimum of three characters (ex: 242A, 3W3C). Enter full part number to target results. (ex: 242A24180X, 3W3C) If you do not obtain the desired results, try searching again by omitting the suffix and searching product family. Search results are sorted by part number and upload date.
D38999 Series III Filter Connectors - Amphenol Aerospace
Amphenol’s MIL-DTL-38999 Series III connectors are unrivaled in their performance and reliability. With added filter features, the high-performance general duty threaded connector is designed to withstand the pressures of severe environment applications.
Backshells | Amphenol LTD
Each backshell can be used on both plug and receptacle of the same connector range and size (ex: TV NSA 15 014 can be put at the rear of both TV06RW1535P and TVP00RW1535S or TV07RW1519P) ... MIL-DTL-38999 series I connectors are generally not delivered with backshell, except for: LJT xx RE versions (= JMS27xxx E), which are delivered with ...
INDUSTRIAL MONITORING INSTRUMENTATION - PCB
SERIES (EX)64X. n. Available in top or side exit casings. n. Peak or RMS, acceleration or velocity. ICP ® IN-LINE TRANSMITTER. MODEL 682A09. n. Converts ICP ® sensors to loop powered transmitters. n. Outputs 4-20 mA proportional . to velocity plus analog raw vibration output. ULTRA LOW FREQUENCY. DISPLACEMENT SENSOR. MODEL 653A01. n Ideal for ...