Search Results for ex series
Thermometrics NTC Type 95 Series Thermistors
Type 95 Series Thermometrics Thermistors Features • Precision, solid state temperature sensor • Interchangeability down to ±0.18°F (±0.1°C) • Suitable for use over a range of -112°F to 302°F (–80°C to 150°C) • High sensitivity, greater than –4%/°C at 77°F (25°C) • Suitable for temperature measurement, control and ...
transportation-rail-mass-transit-pyle-national-catalog-amphenol-industrial
S500 series suffix indicates a deviation from standard. Consult factory for call out. ORDERING INFORMATION Standard Car to Car Jumper Locomotive Jumper Receptacle Amtrak Pyle Number WWPCJ-2746-AMTR WWPCJ-2757-AMTR-LOCO WWRF-27-AMTR-L180 Ordering Information Amtrak AMMS No. 25 789 0841X 24 808 03177 25 78907812
Industrial | Markets - Amphenol
This series, a commercial MIL-DTL-26482, Series 1 solder contact, general duty or ruggedized harsh environment, metal bayonet coupling, power, and signal connector. With over 60 insert arrangements ranging from 1 to 61 contacts per connector and up to 23 amps possible with a standard operating temperature from -55°C to +125°C.
Charles Universal Broadband Enclosures - Charles Industries
Select CUBE RL Series Cabinets also have Small Cell applications. SC1042NAN2 SC20942NE2 SC3042NNE2 RL20721 SC21632DP2 CUBE Series Height Weight Depth Description LOW-PROFILE SMALL CELL CABINETS CUBE-SC104 Series 24”-48” 10.5” 19” Power & Battery Only, 4RU, 19" Fixed Rail, Battery Compartment for Battery String HIGH-POWER SMALL CELL CABINETS
IECEx Gert¡f¡cate Gonformity - sgxsensortech.com
VQ500 Series Gas Sensing Heads Type of Protection: Flameproof Marking Ex db Ex db cGb Mb Approved for r'ssue on behalf of the IECEx Ceftificatíon Body: Position: C Ellaby Deputy Certification Manager Signature: (for pinted version) Date: S-1. This certificate 2. This certificate 3. The Status and IECEx Website Certificate issued by: SIRA ...
www.amphenol
series I, II and III •t performance capabilities for both Highes general duty and severe environment appli-cations •t or exceed MIL-DTL-38999 requireMee - ments •designed for the harshest enOriginally - vironments and most demanding applica-tions •tinue to evolve with the needs of an Con ever-changing market. Amphenol Martec. TV-SIM
EUD-0066 VQ500 DoC & Special Instructions V1 - sgxsensortech.com
VQ500 Series EU Declaration of Conformity EUD-0066 EUD-0066 Issue 1 10-Jan-13 PRODUCT SERIES: VQ500 Series PRODUCT TYPE: Miniature Gas Sensing Head PRODUCT ... II 2G Ex d IIC Gb Ta -40˚C to +55˚C I M2 Ex d I Mb Ta -40˚C to +55˚C Richard Lane Quality and Operations Manager .
Model 649A01 Reciprocating Machinery Protector (RMP) Installation ... - PCB
(EX)649AX1-Series Reciprocating Machinery Protector (RMP) Operating Guide with Enclosed Warranty Information 3425 Walden Avenue, Depew, New York 14043-2495 Phone (716) 684-0003 Fax (716) 684-3823 Toll Free Line 1-800-959-4IMI MANUAL NUMBER: 38281 MANUAL REVISION: F ECO NUMBER: 49766 . 2
AI900の資格 | Amphenol Global Search | Amphenol
詳細は別紙1 のとおり 防爆構造の種 類. 耐圧防爆構造、容器による粉じん防爆構造. 対象ガス又は蒸気の. 発火度及び爆発等級 IIC T4Ga/Gb . IIIC T130°C Db. 製品上の. Ex: マーキング Ex d IIC T4 Ga/Gb Ex d e IIC T4 Ga/Gb Ex t IIIC T130°C Db . 定 格: DC 24V 使用条件. 詳細は別紙. 2 ...
Data Sheet E-Series EH Analog - Temposonics
I 2 I Temposonics® E-Series EH Analog Data Sheet 4 5 3 1 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (Waveguide)
Temposonics
Temposonics® Magnetostriktive lineare Positionssensoren EP / EL CANopen Datenblatt – Für Standardapplikationen – Positionsmessung mit mehr als einem Magneten
fakra | Amphenol Global Search | Amphenol
RF Connector FAKRA Generation 3 Straight Crimp Jack RG-174 RG-188 RG-316 Times LMR-100A 50 Ohm IP67 C Key Code Downloads 349-50832 Assembly Instructions (Size: 475 kb)
21-33384-91 (PIN) 21-33385-91 (SOCKET) Contact, Pin and Socket, Quadrax ...
Contact, Pin and Socket, Quadrax, Type M38999 Series I & III Special, Size 8 Installation Instructions See table on reverse side for quadrax cable recommended, tool selector settings, crimping tool, positioner and insertion/removal tool information. A 1. Cut cable for assembly of quadrax contacts.
21-33384-51 (PIN) 21-33385-51 (SOCKET) A A1.Cut cable for ... - Amphenol
Contact, Pin and Socket, Quadrax, Type M38999 Series I & III Special, Size 8 Installation Instructions See table on reverse side for quadrax cable recommended, tool selector settings, crimping tool, positioner and insertion/removal tool information. A1.Cut cable for assembly of quadrax contacts.
fpc | Amphenol Global Search | Amphenol
Amphenol is one of the leading manufacturers of PWRMAX® POWER CONNECTOR. Contact us today for more details of PwrMAX®, part number 10136689-002LF.
Charles Universal Broadband Enclosures
Select CUBE RL Series Cabinets also have Small Cell applications. SC1042NAN2 SC20942NE2 SC3042NNE2 RL20721 SC21632DP2 CUBE Series Height Weight Depth Description LOW-PROFILE SMALL CELL CABINETS CUBE-SC104 Series 24”-48” 10.5” 19” Power & Battery Only, 4RU, 19" Fixed Rail, Battery Compartment for Battery String HIGH-POWER SMALL CELL CABINETS
Charles Universal Broadband Enclosures
Select CUBE RL Series Cabinets also have Small Cell applications. SC1042NAN2 SC20942NE2 SC3042NNE2 RL20721 SC21632DP2 CUBE Series Height Width Depth Description LOW-PROFILE SMALL CELL CABINETS CUBE-SC104 Series 24”-48” 10.5” 19” Power & Battery Only, 4RU, 19" Fixed Rail, Battery Compartment for Battery String HIGH-POWER SMALL CELL CABINETS
Temposonics
I 2 I Temposonics® EH Analog Data Sheet 4 5 3 1 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (Waveguide)
www.sgxsensortech.com
Ex Component: IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification System for Explosive Atmospheres for rules and details of the IECEx Scheme visit www_iecex.com Ex COMPONENT CERTIFICATE Certificate history: Issue 6 (2016-02-12) Issue 5 (2015-03-23) Issue 4 (2012-11-14) Issue 3 (2011-02-14)