Search Results for ferrule-174
www.amphenolrf.com
S 'de ferrule over cable. Trim cable to d mensions shown in table above. Tin center conductor Assemble contact over center conductor so that shoulder of contact butts against cable delectric. Heat contact to so der. Insert cable and contact into back end of crimp body. Contact shoulder will bottom in nsulator. Sl de ferrule over braid and
n112a2-001-nt3g-9913-50sap | Amphenol Global Search | Amphenol
Assembly Instructions-C26 Amphenol BNC. 300. Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com. 3-PIECE CRIMP PLUGS. Amphenol Connector Cable Hex Crimp Data Stripping Dimensions, inches (mm) Number Type RG-/U Cavity for Cavity for Die Set for CTL Series Contact Outer Ferrule Tool 227-944* Tool Number ab c 36650-1003BNC Plug Belden 82907 ...
Mil-Spec and Custom Circular Connectors - Amphenol Aerospace
Amphenol doesn’t just offer connectors within standard MIL-SPEC boundaries; customization beyond MIL-SPEC standards to craft any interconnect solution to meet your unique needs is available through our 38999 Plus catalog.. Whether it’s signal connectors, power connectors, hybrid or high-speed connectors, 38999 Plus presents a massive inventory of MIL-SPEC styles and options to overcome any ...
Mastering RJ45 Connectors: A Step-by-Step Guide for Installation on ...
As the backbone of modern networking, RJ45 Connectors play a pivotal role in establishing secure and efficient connections. We created an incredible instructional guide that takes you step-by-step on how to install RJ45 Field Installable Connectors for large Ethernet Cables such as CAT 7, CAT 6, and Profinet cables. Within the video and blog post provided, you will find a wealth of information ...
Amphenol
Amphenol is one of the world’s largest providers of high-technology interconnect, sensor and antenna solutions. Our products Enable the Electronics Revolution across virtually every end market including Automotive, Broadband Communications, Commercial Aerospace, Defense, Industrial, Information Technology and Data Communications, Mobile Devices and Mobile Networks.
MIL-C-39012 INSPECTION - Amphenol
d. crimp ferrule with 0.429" hex die. 6. shows cable entry dimensions. mil-c-39012 inspection scale 1.600 stamp "m39012/01b0007 74868 xxxx" in (4 digit date code, year and week) interface per mil std-348 series:type n plug contact ferrule recommended cable stripping dimensions
2fa1-nasp | Amphenol Global Search | Amphenol
FAKRA GEN 2 Straight Crimp Plug RG-174 RG-188 RG-316 Times LMR-100A 50 Ohm IP67 A Key Code 2FA1-NASP-C01E1. ... FAKRA GEN 2 Straight Crimp Plug RG-58 RG-141 Times LMR-195 50 Ohm Z Key Code 2FA1-NZSP-C04W1. Contact Us. Subscribe and Stay Connected with Amphenol RF. Submit. By submitting your email, you are agreeing to receive occasional updates ...
Understanding Different Cable Gland Thread Types: NPT, Metric, & PG
Cable glands are an essential component of any electrical installation, and understanding the different types of thread used in cable glands is important. The three most common types of threads used in cable glands are NPT, Metric, and PG. Understanding the differences between these thread types will help you choose the right cable gland for your needs.
031-9-RFX | Amphenol Global Search | Amphenol
BNC Right Angle Crimp Plug RG-59 Plenum 20 AWG 75 Ohm 031-71010-RFX. BNC Straight Crimp Jack AT&T 735 AT&T 735A Belden 735A1 Bulkhead Rear Mount 75 Ohm 112969. BNC Right Angle PCB Jack Through Hole 75 Ohm 112659-75. BNC Straight Crimp Plug RG-174 RG-188 RG-316 Times LMR-100A 50 Ohm 112136.
Customer Drawings - Document Library | Page 231
Featured Category. RF Connectors; 1.0-2.3 Connectors; 1.6-5.6 Connectors; 2.2-5 Connectors; 2.92 mm Connectors
3126 | Amphenol Global Search | Amphenol
95077 m39012/55-3126 3) break corners & edges .005 r. max. within .005 t.i.r. west palm beach, fl 33409 title: is the sole property of sv microwave, inc. cage code 2) all dimensions are after plating.
CRIMP TYPE PLUGS & BULKHEAD JACKS - amphenolrf.com
Number Type for Outer Ferrule Tool Handle 227-944 a b c 903-108J-71S 75ΩSMB Bulkh Jack 179 .128(3.3) 227-1221-03 Cav. A .673(17.1) .433(11.0) .093(2.4) ... 903-285P-51S 50ΩSMB Plug 174, 179, 187, 188, 316 .128(3.3) 227-1221-03 Cav. A .642(16.3) .402(10.2) .080(2.0) 903-287P-51S 50ΩSMB Plug 178, 196 .105(2.7) 227-1221-03 Cav. B .642(16.3 ...
RIGHT ANGLE PLUGS & CRIMP TYPE - Amphenol RF
919-104P-51AX 50µ MCX Angle Plug 174, 188, 316 .128 (3.25) CTL -13 .337 .133 .106 ... ferrule over braid and crimp using hex die shown in table above. Step 3 Solder center conductor into contact. Step 4 Insert cap into body and dimple or lightly punch center of cap for retention in body.
Power Cable - TPC Wire
Power cables are the life source of any operation and need to be durable and reliable from start to finish. Super-Trex® Portable Power Cables range from 600 Volt to 35 kV and are designed with high-quality compounds to meet all the industry standards and provide excellent service and long-term reliability against industrial and environmental abuse.
www.amphenolrf.com
S 'de ferrule over cable. Trim cable to d mensions shown in table above. Tin center conductor Assemble contact over center conductor so that shoulder of contact butts against cable delectric. Heat contact to so der. Insert cable and contact into back end of crimp body. Contact shoulder will bottom in nsulator. Sl de ferrule over braid and
Wire & Cable Resources | Amphenol TPC Wire & Cable
Read case studies, watch videos and download product literature from the Amphenol TPC Wire & Cable resource portal.
Amphenol Connector Reference Guide - Volume 2
Fiber optics available with MIL-PRF-29504 termini, MT ferrule termini, and ARINC 801 termini; Options include Hermetics, Filters, and Thermocouples; Self-locking quick disconnect threaded coupling; Corrosion resistant - shells of stainless steel or cadmium plate over nickel withstand a 500-hour salt spray exposure
Chem-Gard® 200 RTD Cable - TPC Wire
Chem-Gard® 200 RTD (Resistance Temperature Detector) Cable is a high-temperature and chemical-resistant cable for control and instrumentation applications that can withstand a maximum conductor temperature of 200°C / 392°F.
RIGHT ANGLE PLUGS & CRIMP TYPE - amphenolrf.com
919-104P-51AX 50µ MCX Angle Plug 174, 188, 316 .128 (3.25) CTL -13 .337 .133 .106 ... ferrule over braid and crimp using hex die shown in table above. Step 3 Solder center conductor into contact. Step 4 Insert cap into body and dimple or lightly punch center of cap for retention in body.
Home - XMA
Coupling transmission lines with low insertion loss; Resources. Distribution Partners Need components fast? Ask our distributors; Territorial Sales Representatives Your local resources; Publications Check us out in publications; XMA Blog Living and learning about quantum computing, space, and more; About