Search Results for ferrule
CUSTOMER OUTLINE DRAWING
crimped ferrule hex crimp size .128" 5. contact pin to solder 6. shows cable entry dimensions. interface per cecc 22220 mcx plug spacer scale 5.000 customer outline drawing all other sheets are for internal use only 6 6. author: amphenol rf created date:
Amphenol Low Back Reflection Fiber Optic APC28876 Fiber Systems
About the APC28876 Series. Amphenol Fiber Systems International (AFSI) is pleased to announce the introduction of our APC28876-series low back reflection, multi-channel fiber optic connectors. These cutting edge connectors are based on field proven, time tested MIL-PRF-28876 connectors. AFSI’s industry-leading position in both MIL-spec and ...
Amphenol Aerospace
ferrule forward over the cable braid until it comes to a stop. 3. Crimp the outer contact and ferrule using the crimp tool and positioner listed in the table. Crimp once, rotate the tool 45 degrees and crimp again. (.156 Dia. Max. over the ferrule after crimping). Rotate tool 45 degrees and crimp again if necessary. 4.
REV. 11/'E/97 MAN BODY DESCRIPTION RELEASE FERRULE STEP 1. ALL PARTS OF ...
ferrule step 1. all parts of connector are shown. step 2. strip the cable inner conductor, braid and as step sloe ferrule onto cable. step a. insert acor into brad ano dielectric. then ferrule over proper tool. step s. solder to the of main soar. then screw into 't stops. if press cap is pro'oed. press into place_ connector car oratlon angle crimp
Amphenol FO-9LPBMTRJ00-001 MT-RJ Connector Loopback Cable: Single-Mode ...
100% optically tested single-mode 9/125 fiber optic loopback cables by Amphenol meet and exceed industry standard specifications for insertion loss, return loss, and endface geometry. Features tight buffered 9.0-micron fiber with precision terminated MT-RJ connectors for fiber optic test applications.
PRODUCT DATA DRAWING - DCN 40734 08/14 FSG DESCRIPTION - SV Microwave
ferrule & swept contact: beryllium copper per astm b196, alloy no. uns c17300, td04 solder on contact: brass per astm b16, alloy uns no. c36000 insulators: ptfe per astm d1710, type i, grade 1, class b finish: body, ferrule & contacts: gold per astm b488, type ii,
Installation guide for hazardous areas - Wilcoxon Sensing Technologies
Any installation of devices within a hazardous area as defined in the NEC® or ATEX Directive MUST BE in accordance with that device's CONTROL DRAWING and local ordinances. Wilcoxon Sensing Technologies. Tel: +1 (301) 330-8811. 8435 Progress Drive. Tel: +1 800 WILCOXON. Frederick, MD 21701. Fax: +1 (301) 330-8873.
CUSTOMER OUTLINE DRAWING
ferrule heat shrink tube stamp "amphenol 901-101" interface per sma plug customer outline drawing all other sheets are for internal use only 6 6. created date:
REV. 11/'E/97 MAN BODY DESCRIPTION RELEASE FERRULE STEP 1. ALL PARTS OF ...
ferrule step 1. all parts of connector are shown. step 2. strip the cable inner conductor, braid and as step sloe ferrule onto cable. step a. insert acor into brad ano dielectric. then ferrule over proper tool. step s. solder to the of main soar. then screw into 't stops. if press cap is pro'oed. press into place_ connector car oratlon angle crimp
Amphenol RF
crimping tool. Slide the FERRULE onto the cable. CRIM Insert the MAIN BODY into the braid and dielectric until it bottoms against the insulator. Slide the FERRULE over the braid and crimp. IMP Insert MAIN BODY into the PLASTIC HOUSING, and press the LOCKING CLIP into it. Verify pin height from end Of SMB metal body to top Of contact(l. 18-1.81mm).
32 CHANNEL 10G ETHERNET SWITCH - Amphenol Aerospace
(1x) 48f mt ferrule 12599 (1x) mt male kit cf-198233-001 cf-594611-01p 48f mt ferrule 12599 mt female kit cf-198234-001 j3 10-646402-612n 8x) 21-032907-001 octonet, socket tv06rqf-25-8p(lc) 21-032904-021 octonet, pin compatible w/ pic e6a3824 100ohm cable (or equivalent) j4 debug cf-971353-22p (22x) size 22d pin m39029/107-620 v06rf-13-35s(lc ...
Assembly Instructions-C11 Amphenol Type N
Step 2 Slide outer ferrule onto cable as shown. Flare slightly end of cable braid as shown to facilitate insertion of inner ferrule. Important: Do not comb out braid. Place contact on cable center conductor so it butts against cable dielectric. Center conductor should be visible through inspection hole in contact. Crimp or solder contact
Assembly Instructions-C11 Amphenol Type N
Step 2 Slide outer ferrule onto cable as shown. Flare slightly end of cable braid as shown to facilitate insertion of inner ferrule. Important: Do not comb out braid. Place contact on cable center conductor so it butts against cable dielectric. Center conductor should be visible through inspection hole in contact. Crimp or solder contact
Amphenol Aerospace
2. Bring outer crimp ferrule forward over cable inner flat braid as illustrated. (Continue to push the inner contact assembly fully forward while bringing the outer crimp fer-rule into position). 3. Crimp outer crimp ferrule using crimp tool listed in table. ( .156 Max. over ferrule after crimping). Trim excess braid ahead of crimp ferrule, if ...
PRODUCT DATA DRAWING - SV Microwave
ferrule & contact: gold per astm b488, type ii, code c, class 0.76, over nickel per ams-qq-n-290, class 1, .00005" min. lockwasher: passivated performance: impedance: 50 ohms freq. range: dc to 18.0 ghz. product data drawing recommended mounting hole date approved revision history
Assembly Instructions-C11 Amphenol Type N
Step 2 Slide outer ferrule onto cable as shown. Flare slightly end of cable braid as shown to facilitate insertion of inner ferrule. Important: Do not comb out braid. Place contact on cable center conductor so it butts against cable dielectric. Center conductor should be visible through inspection hole in contact. Crimp or solder contact
CRIMP TERMINATION FOR TYPE 2 – 75ΩCONNECTORS
outer ferrule over braid and up against connector body. Crimp outer ferrule using Die Set Cavity specified in table above. * for pneumatic crimp tool 227-60, use die sets indicated in this column outer ferrule bushing male contact plug body assembly female contact jack body assembly for use on RG-62, 71, 210 cable only Step 1
Assembly Instructions-C11 Amphenol Type N
Step 2 Slide outer ferrule onto cable as shown. Flare slightly end of cable braid as shown to facilitate insertion of inner ferrule. Important: Do not comb out braid. Place contact on cable center conductor so it butts against cable dielectric. Center conductor should be visible through inspection hole in contact. Crimp or solder contact
High Speed I/O Cables | High Speed Cable Assemblies | Amphenol ICC
Cables | High Speed I/O. Amphenol is a technology leader in the design, manufacture, and supply of high-performance copper cable assemblies. Our global footprint and track record is unparalleled in the industry, with a customer base that includes all major data center, networking, HPC, telecom, server and storage system platform providers.
CRIMP TERMINATION FOR TYPE 2 – 75ΩCONNECTORS - Amphenol RF
outer ferrule over braid and up against connector body. Crimp outer ferrule using Die Set Cavity specified in table above. * for pneumatic crimp tool 227-60, use die sets indicated in this column outer ferrule bushing male contact plug body assembly female contact jack body assembly for use on RG-62, 71, 210 cable only Step 1