Search Results for friedman test
Temposonics
EMC Test: Electromagnetic emission EN 50081-1 Electromagnetic immunity EN 50082-2 EN 61000-4-2/3/4/6, Level 3/4, Criteria A, CE qualified Operating Voltage: +24 Vdc nominal (-15 or +20%) Polarity protection: up to -30 Vdc Overvoltage protection: up to 36 Vdc Current drain: Analog: 50 - 140 mA
SensorCheck App - AIRMAR EMEA
Accurately test both traditional and CHIRP-ready transducers that operate at frequencies ranging from 10 kHz to 500 kHz. With CHIRP-ready units and any traditional units over 1kW and above, the TDT1000 will automatically read Xducer ID ® features such as transducer model, frequency, part number and serial number.
HD-BNC Straight Crimp Plug Belden 1855A 75 Ohm | 034-1037 - Amphenol RF
RF Connector HD-BNC Straight Crimp Plug Belden 1855A 75 Ohm
Model 109D12 | PCB Piezotronics
Model 109D12:High pressure ICP® ballistic pressure sensor, 100k psi, 0.07 mV/psi, accel. comp.
Model 641B11 | PCB Piezotronics
Model 641B11:Industrial vibration sensor, 4 to 20 mA output, 0 to 1 in/sec RMS, 10 to 1k Hz, top exit, 10-ft integral cable
CB2 cable termination junction box for accelerometer sensors
2-channel cable termination junction box for IEPE accelerometers, BNC jacks, NEMA 4X rated industrial enclosure, cable grips. Buy This Online Now!
Model 113B28 | PCB Piezotronics
Model 113B28:Platinum Stock Products; High frequency ICP® pressure sensor, 50 psi, 100 mV/psi, 0.218" dia. diaphragm, accel. comp.
VIBRATION FUNDAMENTALS - PCB
measurement limits for any test (ex: ± 5% or ± 3dB). The graphic below shows the relationship between sensitivity and frequency: Time Constant (RC) Instantaneous Charge (q) 0 1 3 5 37% 100% Input Output (A) C R q = Qe-t/RC-3 dB 0 dB-5% f L Frequency (Hz) Sensitivity 3f L 9f L 0.2f r 0.5f r f r Log Scale ± 3 dB Response Range ± 5% Response ...
AMPHENOL /PYLE-NATIONAL
(Sea Level) Test Voltage (Sea Level) Test Voltage 50,000 ft. Test Voltage 70,000 ft. Test Voltage 100,000 ft. AC (AMS) DC I 600 850 1800 V RMS 600 V RMS 400 V RMS 200 V RMS M 400 550 1300 V RMS 550 V RMS 350 V RMS 200 V RMS. oe yder fce 1 67 563-51 ...
PCB Product Finder for Accelerometers - Industrial (en)
3425 Walden Avenue Depew, NY 14043. Sensorline SM 716.684.0001. info@pcb.com +1 800-828-8840
Modal Shakers | PCB Piezotronics
The Modal Shop’s modal shakers are a proven solution in test laboratories around the world. With force ratings from 4.5 to 60 lbf (20 to 267 N), these shakers are suitable for a wide range of modal analysis applications. When performing experimental modal analysis and structural testing, the choice of excitation function and system will make ...
Model 356A16 | PCB Piezotronics
Model 356A16:Platinum Stock Products; Triaxial, high sensitivity, ceramic shear ICP® accel., 100 mV/g, 0.5 to 5k Hz, aluminum hsg, 4-pin conn.
R-VPX VITA 46 Connector System | Products | Amphenol Aerospace
RVPX VITA 72 vibration test Evaluation of R-VPX product to VITA 72 vibration levels View Download. R-VPX Connector Features. 1:51. R-VPX Ruggedized VITA 46 Connectors – Amphenol New Product Collaboration. 3:34. Amphenol-BSI Overview. 4:22. R-VPX Evolution ...
Extreme Low Temperature Pressure Measurements Using Cryogenic Dynamic ...
The test variables were temperature and pressure, with voltage output being the measured . result from each unit under test. For charge mode units, the units were tested at room temperaturewhich ranged from 64, 74°F- , and again at Liquid Helium ( LHe) temperature of -415°F. For ICP® output devices, units were tested at room temperature and
Enclosures | PCB Piezotronics
PCB ® manufactures sensors used by design engineers and predictive maintenance professionals to test and measure vibration, pressure, force, acoustics, load, and shock in research and development as well as industrial applications. Divisions of PCB. Subscribe.
Model 483C28 | PCB Piezotronics
Model 483C28:8-channel, line-powered, bridge/differential/ICP® sensor signal cond., incremental gain, Autozero, Ethernet
Structure Family - amphenol-sine.com
No cracking, chipping or leaking after 20 test cycles from -55°C to +125°C. Physical Shock No unlocking, unmating or other unsatisfactory results during or after 50 G’s in each of three usually perpendicular planes. No electrical discontinuities longer than 1 microsec-ond. MIL-STD 202. Method 213, Condition “C”. Vibration
Xducer ID® Technology - Airmar
Airmar's Xducer ID technology is made possible by a small microcontroller that is embedded into every AIRMAR broadband transducer. During final test at the factory, the transducer’s unique details are measured and stored in memory, enabling the echosounder to automatically configure itself to the transducer being used.
Dynamic Cryogenic Pressure Sensors - PCB
Sensors for Test & Measurement > Pressure Transducers > Cryogenic. Dynamic Cryogenic Pressure Sensors ICP Series 102. The 102 Series ICP® pressure sensors feature ground isolation and low operating temperature capability ideal for measuring cryogenic pumps, cryogenic fuel systems, and rocket motor combustion instability. Each sensor is ...
Model J356A03 | PCB Piezotronics
Model J356A03:Triaxial, lightweight miniature, ceramic shear ICP® accel., 10 mV/g, 0.25" cube, ground isolated