Search Results for fuel pump pressure gauge
Thermometrics temperature sensor solutions - amphenol-sensors.com
fuel economy, safety, and control of exhaust emissions. Our comprehensive product range includes temperature sensors for use in coolant or transmission fluid; high temperature sensors to measure exhaust gas temperature; IR, gas management,and humidity sensors for cabin comfort; and solar and light sensors. Our single-piece leadframe
Grainmaster i Intergrated moisture and temperature measurement
The P1302 piezoresistive pressure sensors are offered in a miniature 2.7 mm x 3.2 mm ( 0.10 in x 0.12 in ) die. When excited with 1.5 mA, the P1302 produces a millivolt output that is proportional to input pressure. The P1302 is available as a differential and gage sensor. With NovaSensor’s SenStable® process, the
Grainmaster i Intergrated moisture and temperature measurement
The P1302 piezoresistive pressure sensors are offered in a miniature 2.7 mm x 3.2 mm ( 0.10 in x 0.12 in ) die. When excited with 1.5 mA, the P1302 produces a millivolt output that is proportional to input pressure. The P1302 is available as a differential and gage sensor. With NovaSensor’s SenStable® process, the
Telaire Ventostat T8100 NS and NSP Series CO2 Sensor
configurations are identical. The recommended wire gauge is 18-22 AWG (1.0 to 0.75 metric).!WARNING! Ventostat T8100-NS/NSP products have two terminal pins that are connected inside the sensor to a common/ground: pin #7 on the I/O terminal blocks and pin #2 on the power block. Do NOT connect positive (hot) 24 VAC power line to terminal
Thermometrics temperature sensor solutions - amphenol-sensors.com
fuel economy, safety, and control of exhaust emissions. Our comprehensive product range includes temperature sensors for use in coolant or transmission fluid; high temperature sensors to measure exhaust gas temperature; IR, gas management,and humidity sensors for cabin comfort; and solar and light sensors. Our single-piece leadframe
Thermometrics EMI-Protected NTC Thermistors Datasheet
Title: Thermometrics EMI-Protected NTC Thermistors Datasheet Author: Amphenol Advanced Sensors Subject: With increasing complexity of electric systems and density of electronic components in modern vehicles, conventional NTC thermistor sensors are vulnerable to stray electromagnetic interference causing self-heating.
Thermometrics Medical Sensors
Applications Served • Patient Monitors • Incubators/Infant Warmers • Catheters • Anesthesia/Pulmonary • Sleep Disorder Monitoring • Respirators
Grainmaster i Intergrated moisture and temperature measurement
The P1302 piezoresistive pressure sensors are offered in a miniature 2.7 mm x 3.2 mm ( 0.10 in x 0.12 in ) die. When excited with 1.5 mA, the P1302 produces a millivolt output that is proportional to input pressure. The P1302 is available as a differential and gage sensor. With NovaSensor’s SenStable® process, the
NovaSensor Medium and High Pressure MEMS Pressure Sensor Die
Pressure Differential only 5, 500 psig Differential and absolute 15, 30, 70, 150, 300 psig / psia Absolute only 1000, 1500, 3000, 5000, 10000, 15000 psig Maximum Pressure 2 x pressure, 5000-10000 psi Maximum Pressure 3 x pressure, 5-3000 psi Environmental Electrostatic damage (ESD) Class 1 MIL-STD 883 method 3015 Temperature Range
NovaSensor Medium and High Pressure MEMS Pressure Sensor Die
Pressure Differential only 5, 500 psig Differential and absolute 15, 30, 70, 150, 300 psig / psia Absolute only 1000, 1500, 3000, 5000, 10000, 15000 psig Maximum Pressure 2 x pressure, 5000-10000 psi Maximum Pressure 3 x pressure, 5-3000 psi Environmental Electrostatic damage (ESD) Class 1 MIL-STD 883 method 3015 Temperature Range
Installing the Sensor - amphenol-sensors.com
wiring. The recommended wire gauge is 18-22 AWG (1.0 to 0.75 metric). !WARNING! Ventostat products have three terminal pins that are connected inside the sensor to a common/ground: pin #2, 5 and 7 on the I/O terminal blocks and pin #2 on the power block. Do NOT connect positive (hot) 24 VAC power line to terminal number 2 of the terminal block.
Thermometrics Medical Sensors
Applications Served • Patient Monitors • Incubators/Infant Warmers • Catheters • Anesthesia/Pulmonary • Sleep Disorder Monitoring • Respirators
Model 134A27 Tourmaline ICP® pressure bar with 003 cable and ... - PCB
SERIES 134A20 TOURMALINE PRESSURE BAR GENERAL OPERATION MANUAL 1 1.0 INTRODUCTION Series 134A20 Tourmaline Pressure Bar with In-Line Amplifier consists of a Series 134A Tourmaline Pressure Bar connected to a three-inch, low-noise cable that connects into Series 402 In-Line Source Follower Voltage Amplifier. See Figure 1.
P330W Eval Kit - amphenol-sensors.com
4 Analog Pressure Output @Pmin* AOUTmin 0.5 Volts 5 Analog Pressure Output @Pmax* AOUTmax 4.5 Volts 6 Analog Output Accuracy AACC ±6 mmHg 7 Proof Pressure Pproof TBD mmHg A 8 Burst Pressure Pburst 4500 mmHg A Equation Pressure = (112.5 * Vread) - 56.25 mmHg 3-Pin Connector (Analog) Color Function Yellow Vin Black GND Red Output
Installing the Sensor - amphenol-sensors.com
wiring. The recommended wire gauge is 18-22 AWG (1.0 to 0.75 metric). !WARNING! Ventostat products have three terminal pins that are connected inside the sensor to a common/ground: pin #2, 5 and 7 on the I/O terminal blocks and pin #2 on the power block. Do NOT connect positive (hot) 24 VAC power line to terminal number 2 of the terminal block.
Catheter Pressure Sensors
Title: NovaSensor P330W Absolute Pressure Sensor Author: Amphenol Advanced Sensors Subject: NovaSensor s P330W Absolute Pressure Sensor is a Piezoresistive (PRT) Pressure Die, offering the same superior stability and sensitivity as in larger die, but in an extremely small footprint, making it ideal for invasive app´ Õ»³ZÞ ÷£ ïv r 8Î1{ +Aç ¶=JÈz³ 1: 8 ¸ 1÷ÛL "X¬xçk 0úÁøô ...
Grainmaster i Intergrated moisture and temperature measurement
The P1302 piezoresistive pressure sensors are offered in a miniature 2.7 mm x 3.2 mm ( 0.10 in x 0.12 in ) die. When excited with 1.5 mA, the P1302 produces a millivolt output that is proportional to input pressure. The P1302 is available as a differential and gage sensor. With NovaSensor’s SenStable® process, the
ICP® PRESSURE SENSOR - PCB
113B28 ICP® PRESSURE SENSOR Revision: G ECN #: 54949 Performance ENGLISH SI Measurement Range(for ±5V output) 50 psi 344.7 kPa Useful Overrange(for ± 10V output) 100 psi 689.4 kPa [1] Sensitivity(± 15 %) 100 mV/psi 14.5 mV/kPa Maximum Pressure 1,000 psi 6,895 kPa Resolution 0.001 psi 0.007 kPa [2] Resonant Frequency ≥ 500 kHz ≥ 500 kHz
Modus Series T Differential Pressure Transmitters
Table A find the corresponding pressure code. Then add 0 V (0 to 10 V range) Pressure excursion: 0% to 100% of Range, see Table A. “A” O at 20 mA and a minimum 1/4 span offset. At zero differential pressure, range of -0.33 in of H the output signal is: 1.25 V (0 to 5 V range) 2.5 V (0 to 10 V range) Pressure excursion: -33% to 100% of
NovaSensor P111 Medium Silicon Pressure Sensor Die
NovaSensor’s P111 piezoresistive pressure sensors are offered in a miniature 0.10 in x 0.12 in (2.7 mm x 3.2 mm) die. When excited with 1.0 mA, the P111 produces a millivolt output that is proportional to input pressure. The P111 is available as an absolute pressure sensor where the media pressure is referenced to an internal vacuum sealed