Search Results for ge advanced sensors
250TPA08/nrg250TPA08 - 250A Dual-Feed TPA Fuse Panel
Sensor accuracy -19.99 to +19.99V: ± 0.3V -20V to -60V: ± 0.1V +20V to +60V: ± 0.1V Voltage measurement range -60 to +60 VDC Note: • Voltage measurement may be slightly different than at input terminal blocks due to the voltage drop within the panel. • Sensors are factory calibrated and do not require user adjustment.
Thermometrics ZTP-115 Thermopile IR Sensor - amphenol-sensors.com
Thermometrics ZTP-115 Thermopile IR Sensor Author: Amphenol Advanced Sensors Subject: The ZTP-115 thermopile sensor is used for non-contact surface temperature modeling. Keywords: Amphenol Advanved Sensors; Thermometrics; ZTP-115; IR sensor; thermopile; surface temperature modeling Created Date: 4/3/2019 10:15:50 AM
Model 112A21 | PCB Piezotronics
Seal ring, sensor flush mount, 0.248" OD x 0.219" ID x 0.015" thk, brass (for Series 111A, 112A & 113A) 3: Optional Versions (E) Emralon coating. English SI; Coating: Emralon: Electrical Isolation: 100000000 Ohm (S) Stainless Steel Diaphragm. English SI; Diaphragm: 316L Stainless Steel (W) Water Resistant Cable.
Telaire CO2 Zone Ventilation Control In Buildings Application Note
Advanced Sensors ® Application Note Ventilation control using CO 2 is one of the fastest growing building control strategies being implemented in new and retrofit building projects today. This approach can provide better control of building ventilation, help assure tenant comfort and reduce complaints while reduce operating costs related to ...
www.amphenol-sensors.com
www.amphenol-sensors.com
Cell Connection Systems in e-Mobility - Amphenol CS
At the heart of the battery pack is the cell connection system (CCS), which plays a critical role in ensuring the reliable performance and longevity of the battery. The CCS combines individual cells in a parallel and series configuration, providing both energy and power for the pack and critical sensor data to the Battery Management System (BMS).
ASTG Electrification EV/HEV Applications - amphenol-sensors.com
ASTG Electrification EV/HEV Applications - amphenol-sensors.com
Temposonics
Ø 10 mm sensor rod PN: 350 bar Pmax: 450 bar DIN EN ISO 19879 IP rating sensor housing Sensor housing: IP67, EN60529 Environmental testing: Shock: Vibration: EMC: IEC-68-2-27 100 g (6 ms) single hit 50 g (11 ms) at 1000 Shocks per axis IEC 68-2-6 (10...2000 Hz) Ø 10 mm sensor rod 15g (r.m.s) ISO 14982 agricultural and forestry machines
DoorExplorer UserManual en V3 - Marport
of the Trident or Door Explorer sensor. 99 Chart and 3D Views Are Wrong. 100 In Scala2, Lost is displayed instead of spread . distance 102 Support Contact 104. Appendix 105. Frequency Plan 106. Compatible NMEA Sentences from Winch Control Systems, GPS and Compass . Devices 111 Pocket Drawings 122.
TN-17 Accelerometer Selection Considerations - PCB
This paper will review sensor selection considerations involving two general types of piezoelectric sensors. High impedance, charge output (PE) type and ICP® with a characteristic low impedance output. In addition to sensor electrical and physical characteristics, several factors
www.amphenol-sensors.com
www.amphenol-sensors.com
www.amphenol-sensors.com
www.amphenol-sensors.com
www.amphenol-sensors.com
www.amphenol-sensors.com
10-32 coaxial connector | Amphenol Global Search | Amphenol
without pulling cable. test structure model 030a10 mini coaxial to 10-32 coaxial plug model 352c23 sensor 8.) to avoid unnecessary damage to the sensor and/or cable, use the supplied removal tool (model 039a26). a quick twisting motion will free the sensor from the test structure. fasten cable to test structure typically within 3-4 [76-101] of ...
PORTABLE VIBRATION CALIBRATOR - pcb.com
Model 600A57 Mounting Plate (3 and 4 Hole High-Temp Vibration Sensors) (1) Model ICS-41 NIST traceable Certificate of Calibration, Metric & English Units (1) Model M081A63 Mounting stud, 1/4-28 to M8 x 1.25, BeCu with shoulder (1) Model USB DRIVE Flash Drive with Calibration Report Generation Worksheet (1)
Operation Manual E-Series ET SSI - Temposonics
damage to the magnet and the sensor rod. If there is contact between the moving magnet including the magnet holder and the sensor rod, make sure that the maximal speed of the moving magnet is less or equal 1 m/s. 10.Ground the sensor via the ground lug. Both the sensor and the moving magnet including magnet holder must be connect-
brocade 300 firmware download | Amphenol Global Search | Amphenol
The firmware version of the sensor is earlier than FIRM450-02.01.15. Update the sensor firmware to an A2S firmware version FIRM450-02.01.15 or above, and bootloader version FIRM445-02.00.06 or above, using the ...
Amphenol Network Solutions > WaveTrax—A sturdy, rigid cable raceway ...
Addit i onal rows:: I nstall a Wav e Trax Express T I n t erch a n ge to add a row of equ i pment and d i st r i bute f i ber from existing trough. No cutting. 24" trough solution:: Develop a 24" (plus) wide trough sol uti on by mounting another 4 " x 12" trough parallel to your existi ng trough, and connect the two troughs with an E xpress ...
P703B 3-channel accelerometer power supply - Wilcoxon Sensing Technologies
P703B accelerometer power supply for three IEPE accelerometers, accelerometer power supply