Search Results for generate signals simulink
4201–00 4-Wire 4-Way and 4202–00 4-Wire 6-Way Conference Bridges
Data or VF signals enter the 4201–00 on the RCV LINE 1 tip and ring leads (pins 1 and 2, respectively) and are transformer-coupled (via T1) to the input of operations amplifier U2–1. A –7db RCV PAD can be selected to pro-vide the proper level for 4-wire carrier applications. The front-panel-accessible RCV LEVEL potentiometer, con-
AE-AN-TR-024 - TR MULTICOAX SERIES - FOOTPRINT GUIDE
mounts to the board on the footprint, applying signal and ground connections in the correct locations. In a standard footprint .pdf there will be several individual footprints on different pages. These footprints consist of both microstrip and stripline versions of the different TR mechanical configurations such as straight mount and right angle.
Data Sheet R-Series V RP5 SSI - Temposonics
into an electrical signal. Since the speed of the ultrasonic wave in the waveguide is precisely known, the time required to receive the return signal can be converted into a linear position measurement with both high accuracy and repeatability. R-SERIES V RP5 SSI The Temposonics® R-Series V brings very powerful sensor per-
3652-80 12-Channel and 3652-81 6-Channel 2/4-Wire ... - Charles Industries
Point (TTLP) is the level of analog signal that is transmitted toward the digital network or 0dBm0. Therefore, if the TTLP is set to −16.0 dBm, then a −16.0 dBm0 analog signal will be transmitted onto the network as 0dBm0. From the level adjusting circuit, the analog voice information is converted to digital and multiplexed with the other chan-
A New Approach to Predicting Bearings Failure - PCB
system. Furthermore, the unit provides a second 4 to 20 mA output signal proportional to overall, low-frequency vibration. This low-frequency signal provides an indication of machine running speed faults such as imbalance, misalignment, and looseness. An analog output signal is provided for diagnostic, spectral measurements.
Model 757AL-2K-300 | PCB Piezotronics
Model 757AL-2K-300:2,000g, miniature, damped, high sensitivity, adhesive mount, 25 ft cable, <5,000 Ohms
TN-4 Using the Bias Voltage As a Diagnostic Tool - PCB
Using the Bias Voltage as a Diagnostic Tool 132 USING THE BIAS VOLTAGE AS A DIAGNOSTIC TOOL The bias voltage of an ICP® sensor can be an effective diagnostic tool. Most ICP® sensor signal conditioners, and data collection devices that supply ICP® sensor excitation power, have some means for monitoring or displaying the
Temposonics
verted into an electrical signal. Since the speed of the ultrasonic wave in the waveguide is precisely known, the time required to receive the return signal can be converted into a linear position measurement with both high accuracy and repeatability. ER SENSOR Robust, non-contact and wear free, the Temposonics® linear position
Sound Power Basics Chad Walber Part 1 | PCB Piezotronics
Sound Power Basics Chad Walber Part 1. Learn about acoustics basics and terminology, particle motion vs. waveform propagation, sound fields and octave band analysis.
SCFF 1-TRX 10G & 25G NRZ | Amphenol Active Optics Products
SCFF 1-TRX 10G & 25G NRZ (RUGGED) Size, efficiency & versatility all the way to 28 Gb/s. The rugged SCFF ("Small Cubical Form Factor") is a 1-channel duplex multi-mode (850nm) on-board transceiver with a 12pin electrical interface (SMT) complying specification SFF-8431 for high speed interfaces.It operates at data-rates up to 25Gbps in harsh environment:
Product Finder - Lutze Inc.
LUTZE Inc. 13330 South Ridge Drive • Charlotte, North Carolina 28273 • USA Phone: 704-504-0222 • Fax: 704-504-0223 • E-Mail: info (at) lutze.com
Model 352C23 Platinum Stock Products; Miniature, lightweight (0.2 ... - PCB
Model Number 352C23 ICP® ACCELEROMETER Revision: E ECN #: 42197 Performance ENGLISH SI Sensitivity(± 20 %) 5 mV/g 0.5 mV/(m/s²) Measurement Range ± 1000 g pk ± 9810 m/s² pk
Motion Control Selection Guide - Amphenol Sine
• Secure connection ensures signal integrity and longer contact life • Superior 360° shielding available • Compact strain relief design allows for tighter clearances • Greater fluid resistance with IP67 sealing • Custom colors and labeling available 4 RoHS Align arrows to ensure proper mated connection Push to mate/connect
Data Sheet - temposonics.com
into an electrical signal. Since the speed of the ultrasonic wave in the waveguide is precisely known, the time required to receive the return signal can be converted into a linear position measurement with both high accuracy and repeatability. Measurement Cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld
SGX - SGX Sensortech Sensor
Head office. Switzerland, Courtils 1, 2035 Corcelles-Cormondreche +41 (0) 32 732 16 70. contact@sgxsensortech.com
00611421007 - Amphenol Air LB
Versatility of mixing & matching (RF, Quadrax, Triax, Twinax and Coax, Fiber Optics, RJ45, Signal & Power) Available in standard Mono, 2 & 4 bay, or custom configurations; EN4165 specification is comparable to U.S. MIL-STD-810 in performance; Fire/Smoke/Toxicity conform to ABD0031 and FAR 25853
Model 137B26 Quartz, free-field, ICP® blast pressure pencil ... - PCB
to minimize signals generated by these effects. Photo 2 Common black vinyl electrical tape has been found to be an effective thermal insulating material in many cases. One layer may be used across the end of diaphragm and adaptor. See photo 3. Photo 3 A silicone rubber coating approximately 0.010 inch
AE-AN-SK-006 - SK SERIES - CARE AND MAINTENANCE
%PDF-1.7 %µµµµ 1 0 obj >/Metadata 211 0 R/ViewerPreferences 212 0 R>> endobj 2 0 obj > endobj 3 0 obj >/ExtGState >/XObject >/ProcSet[/PDF/Text/ImageB/ImageC ...
10159561-A00221RLF | PowerStak® | Amphenol
Amphenol is one of the leading manufacturers of Board to Board Connectors. Contact us today for more details of PowerStak ® Connector part number 10159561-A00221RLF
Model 261B01 Triax force link, ICP®, 1000 lb (Fz), 500 lb (Fx,y), 2.5 ...
impedance output signals that can be transmitted over . low cost cables and in adverse, industrial environments. Multi-pin connectors facilitate a single point hookup . with common, multi-conductor cable. Power to operate ICP® sensors is generally in the form . of a low cost, 24-27 VDC, 2-20 mA constant current . supply.