Brief Instruction E-Series - Temposonics
use of a support, rod and position magnet may be damaged. A false measurement result is also possible. Longer rods require evenly distributed mechanical support over the entire length (e.g. part no. 561 481). Use an U-magnet for measurement. Mounting clamps cre I stenin torue Sensor support (for sensors with stroke lengths ≥ 1 meter (≥ 3.3 ft))
g846a | Amphenol Global Search | Amphenol
Get your sample by choosing part number (s) from the product page or using the search box above. Please provide the following details and we will contact you. Alternatively, contact one of our authorized distributors from the listing here. The information below is for reference only.
Introduction to Charge Mode Accelerometers | PCB Piezotronics
10 pC/g X 10 mV/pC = 100 mV/g X 14 g’s = 1400 mV = 1.4 V Example 2 Sensor: 357B03, 10 pC/g sensitivity Charge convertor: 422E52, ±500 pC input range ±500 pC ÷ 10 pC/g = 50 g measurement range. Charge Mode Accelerometer Low Frequency Response.
Signal Conditioning Basics | PCB Piezotronics
Use of a variable 100 ohm resistor will help set the correct resistance more conveniently. Note that this is the only condition that requires the addition of resistance. If the signal is falling (e.g., 1:0.75), the constant current level must be increased or the cable capacitance reduced.
VIBRATION FUNDAMENTALS - PCB
The charge output (pC/g) can then be converted by a charge amplifier or charge converter (mV/pC). Laboratory amplifiers typically have the ability to adjust gain (mV/pC) and measurement range. In-line charge converters typically have a fixed gain and
SeeHawk® Central Workflow Automation Platform - PCTEL
SeeHawk Central is a cloud-based workflow management platform for testing, approving, and tracking in-building critical communications coverage and Emergency Responder Communication Enhancement Systems (ERCES) such as bi-directional amplifiers (BDAs). It makes testing with PCTEL solutions even more efficient, improves collaboration between testing services and public safety agencies, and ...
Product Data Sheet - Temposonics
G-Series model GH and GP sensors are extremely robust and are ideal for continuous operation under harsh industrial conditions. Backward compatibility with upgraded performance is one of the pri-mary benefits of choosing a G-Series sensor. The G-Series sensor provides the same functionality as our legacy Temposonics I, II and L-Series
Sensor Configuration - marport.com
To configure the sensor, you need to connect it to Mosa2 using a wireless communication or using the Configuration Cable. Calibrating the Catch Sensor You need to calibrate the catch sensor to make sure you have correct catch measures.
Operation Manual TempoLink Smart Assistant - Temposonics
Tepoin ® art ssistant Operation Manual I 3 I 1. Introduction 1.1 Purpose and use of this manual Before starting the operation of TempoLink® smart assistant, read this documentation thoroughly and follow the safety
Operation Manual R-Series V SSI 552011 - Temposonics
Temposonics® R-Series V Analog Operation Manual I 5 I 3.1 Order code of Temposonics® RP5 3. Identification a Sensor model R P 5 Profi le b Design G Magnet slider backlash free (part no. 253 421) L Block magnet L (part no. 403 448) M U-magnet OD33 (part no. 251 416-2) N Magnet slider longer ball-jointed arm (part no. 252 183) O No position magnet S Magnet slider joint at top (part no. 252 182)
Protimeter Technician's Kit: HygroMaster 2 | Protimeter
for use with: • Wood • Drywall • Building Materials • Concrete Protimeter Technician's Kit - Flexibility in a durable carrying case with foam inserts to protect meters and accessories.
VIBRATION FUNDAMENTALS - PCB
The charge output (pC/g) can then be converted by a charge amplifier or charge converter (mV/pC). Laboratory amplifiers typically have the ability to adjust gain (mV/pC) and measurement range. In-line charge converters typically have a fixed gain and
M2803 Series - amphenol-aerospace.com
INHIBIT signal (connector J2, pin G) The INHIBIT signal is used to turn the power supply ON and OFF. To turn the power supply ON, leave pin G open. To turn the power supply OFF, short pin G to pin F. If not used, leave pin G unconnected. This signal is referenced to INHIBIT RTN (connector J2, pin F) PWR GOOD signal (connector J2, pin D)
Amphenol Connex
Crimp tool 47-10000 is for use with all die sets listed in the crimp tooling information chart to the right. Code.042 .052 .068 .080 .100 .118 .128 .151 .178 .190 .213 .255 .263 .278 .320 .324 .350 .429 .610 Crimp Tool & Die Set Die Set Only Hex Crimp Dimension (Inches)
Temposonics
Temposonics® R-Series EtherNet/IP TM Operation Manual I 5 I 3.2 Order structure of R-Series RH */ Non Standard stroke lengths are available; must be encoded in 5 mm / 0.1 in. increments 4/ Note: Please specify magnet numbers for your sensing application and order separately Temposonics® order code a Sensor model R H Rod b Design M Flange M18×1.5 (Standard) V Flange M18×1.5 with ...
SS60 Traditional/CW Tilted Element™ Thru-hull - Airmar
600 W. The SS60 is a 600 W, 50/200 kHz transducer which integrates Airmar’s popular, Tilted Element ™ feature. This Tilted Element transducer has the ceramic element fixed at a 20° or 12° angle within the housing.
Model 356A32 Platinum Stock Products; Triaxial, mini (5 gm) high ... - PCB
Platinum Stock Products; Triaxial, mini (5 gm) high sensitivity, ICP® accel., 100 mV/g, 1 Hz to 4k Hz, titanium hsg, 10 ft mating cable supplied Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987
G-Series Position Sensors - Temposonics
Temposonics ® G-Series linear position sensors provide high durability and accurate position measurement solutions in harsh industrial settings.. Different position sensor models for different purposes of position measurement: Rod version (GH) for cylinder integrated position measurement and for retrofitting legacysensor models
10142708 | Amphenol Global Search | Amphenol
L-2035-AN FSCM 77820 May 2007 21-33122-562 Amphenol Aerospace AMPHENOL CORPORATION Amphenol Aerospace 40-60 Delaware Avenue Sidney, New York 13838-1395 www.amphenol-aerospace.com CONTACT MUST BE SEATED.270 TRIM EXCESS SHIELD.240.108 DIA MAX OUTER PIN CONTACT SHIELD CRIMP SLEEVE FRONT INSULATOR REAR INSULA TOR COMB SHIELD FORWARD CONTACT MUST ...
Temposonics II
degree of accuracy and resolution. Using the principle of magnetostriction (see Section 1.1, below), the Temposonics II LDT measures the time interval between the initiation of an interrogation pulse and the detection of a return pulse. A variety of interface devices use the data derived from these two pulses and generates an ana-