Search Results for hta 1001
Model HT426E01 | PCB Piezotronics
Miniature desktop tripod stand for micro... Add to cart for a quote.
600 Amp DC Current transducer with cable - Gemeco
This Maretron 600 Amp DC Transducer with Cable is an available DCM100 accessory. From the factory, the DCM100 is configured to use a 200A Hall effect current sensor. If you are. type.
NTHBR11A1001SR | Amphenol Global Search | Amphenol
High current contacts for distortion free signal. Cost effective durable thermoplastic shell. Available in 2 and 4 contact arrangements. Overmolded cable support boot or PG gland with or without cable support strain relief. Quick release, vibration resistant latch lock.
TFOCA-II® | 4-Channel Fiber Optic Connector - Amphenol Fiber Systems ...
Meets new mandate set by the Environmental Protection Agency for eliminating heavy metal plating. Explore the TFOCA®-II 4 Channel connector, designed for military tactical deployable networks in harsh environments.
Model 685B1001A30 Electronic vibration switch, remote 100 mV/g ... - PCB
Model 685B1001A30 Electronic vibration switch, remote 100 mV/g accel., 0-1.5 ips, AC powered, 10A form C relays, std enclosure plus external BNC jack, dual ports with cord grips
Level Plus - Temposonics
2 Level Plus ® RefineME® Fig. 1: Time-of-flight based magnetostrictive position sensing principle RefineME® The Level Plus® RefineME® liquid level transmitter satisfies the demand for an accurate and robust liquid-level sensor with unsurpassed flexibility to meet most process application conditions.
PCB Piezotronics | Measure vibration, pressure, force, and more
Find, compare and buy IN-STOCK sensors online today. Visit us at a trade fair or take part in a webinar. Developed for OEM product integration. 2 units in stock! Vibration Transmitter with an IO-Link communication protocol and digital… Miniature, lightweight (0.8 gm) ceramic shear ICP® accel., 100 mV/g, 1 to 8k…
P-U95-T101-1XXX - Sheet5 - Amphenol CS
packaging option 1 = tray packaging (light pipe and/or heat sink shipped loose if ordered) a = tray packaging (light pipe and/or heat sink assembled
R-Series Position Sensors - Temposonics
Temposonics ® R-Series position sensors feature the highest performance, accuracy and reliability in magnetostrictive linear position technology and are designed for advanced motion control implementations in industrial applications.
Data Sheet E-Series EH IO-Link - temposonics.com
I 2 I Temposonics® E-Series EH IO-Link ata Sheet 4 5 3 1 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (Waveguide)
TH Series Time Delay Relay, 200 A - gemeco.com
Protects sensitive on-board electronics via optional under/over voltage shutdown and start event isolation. Ultra-Low Power Draw eliminates vehicle downtime due to dead batteries. Lowest off-state current draw (1.3 mA). Simple & Robust Installation: Sealed plug with optional long wire leads.
1001-6113-0X - XMA
Terminations are power absorbing loads properly matched to the characteristic impedance of a transmission line to prevent signals from reflecting off the end. What does this mean? We cap your wires to ensure your signal stops where and when you want it to.
IPA1001 - Amphenol Broadband Solutions
TRAINING & SUPPORT. Login to the Amphenol Broadband Resource Portal for pre- and post-deployment support. Login
Brief Instruction R-Series - Temposonics
Before starting the operation of Temposonics® position sensors, read this documentation thoroughly and follow the safety information. Keep this manual for future reference! 1 or instructed service technicians who are familiar with the project planning and dealing with Temposonics® position sensors.
1001-6113-0X - Model - xmacorp.com
1001-6113-xx epoxy may protrude yyww 1001-6113-xx as shown xma marking area 10.8.43 .20 5.0 specifications electrical frequency range dc - 18 ghz vswr dc - 4 ghz 1.10:1 max 4 - 12.4 ghz 1.15:1 max 12.4 - 18 ghz 1.25:1 max impedance 50 ohms ...
Data Sheet HIGH PRESSURE HOUSING (HPH) - temposonics.com
Temposonics® High Pressure Housing (HPH) Data Sheet I 3 I TECHNICAL DATA Explosion protection ATEX, IECEx II 2G Ex db IIC T5 Gb T amb −40°C to +75°C II 2D Ex tb IIIC T100°C Db
Absolute, Non-Contact Position Sensors Operating Manual MH Series ...
Temposonics® MH Digital Operating Manual I 3 I 1. Product description and technology Temposonics® sensors can be used in versatile mobile machines without any restriction and replace contact-based linear sensors like poten- tiometers. Highly dynamic systems are controlled safely by means of Temposonics® sensors, thus enhancing the productivity, availability and
Absolute, Non-Contact Position Sensors Protocol Manual MH ... - Temposonics
Temposonics® MH Protocol Manual CANopen I 8 I 7.1.4 Reset_Node indication (9),(10),(11) Through this service the NMT Master sets the state of the selected NMT Slave(s) from any state to the „reset application“ sub-state.
Protocol Manual MH-Series CANopenSafety - Temposonics
Protocol Manual MH-Series CANopenSafety I 7 I If a change of the Node ID or a SRDO safety parameter is required a new checksum must be calculated and programmed by the user.
Temposonics
3 Temposonics® MH Safety Analog / CANopen Data Sheet FUNCTIONAL SAFETY FOR LINEAR POSITION SENSING Temposonics® linear displacement sensors “MH Safety” are based on the magnetostrictive technology and designed according to the requirements out of IEC/EN 61508 and rated with SIL 2 safety level.