Search Results for humidity
High-Density Bulkhead-Style Fiber Optic Splitters Datasheet - Custom Cable
Title: High-Density Bulkhead-Style Fiber Optic Splitters Datasheet Author: Telect Created Date: 4/16/2010 12:03:54 PM
JS8746 Harsh Environment Temperature Sensor | Sensor Assemblies
Thermometrics JS8746 Harsh Environment Temperature Sensor has been designed to address all aspects of temperature measurement for HVAC control systems in the container-ship market, in addition to industrial applications, such as compresors, condensing units, heat pumps, air conditioning.
VQ21T Series Combustible Gas Sensor Elements FEATURES INTRODUCTION ...
Humidity PRINCIPLE OF OPERATION The detector consists of a fine coil of platinum wire embedded in a porous ceramic bead impregnated with a noble metal catalyst. The coil acts as an electrical heater and as a resistance thermometer. The bead is mounted on a header with connecting leads and is surrounded by a metal ...
.093 Piezoelectric accelerometer
Key features n High temperature (260°C) n Miniature design n requires no external power source for operation.360° cable orientation n type P-8 crystal element operating in annular Hermetically sealed n ground is connected to the outer case of the unit.
Fluid-Trac 2-Wire Level Sensor - ssi-sensors.com
Epqshiu & . %%K Ufdiopmphft. NNE 4 Fpd0 HU/CP Tfw0 ssi-sesorsco Note: The Fluid-Trac® 2-wire level sensor comes with an integral gasket that must be used when mounting. Mating connector parts and bolts are not included. Note: Gasoline range is different due to the density of gasoline vapors.Gasoline vapors are denser as the temperature increases which results in the speed of sound being slower.
Document Library - Amphenol Sensors
We believe that making sustainable choices in the way we conduct our business creates short-term and long-term value for our stakeholders. We do not create long-term value by merely complying with regulations, but we go beyond compliance to find ways to green our operations and our products to ensure continuity of the material and human resources that we need to operate the business.
Pulp and paper - Industries - Wilcoxon Sensing Technologies
Vibration sensors for monitoring pulp and paper mill machines: identify early faults, provide warning, extend equipment life, keep machines running.
Models P702B/P702BF-1 operating guide - Wilcoxon Sensing Technologies
90589 Rev C 08/17 Page 6 of 12 3.5 Filtering The P702B power unit/amplifier can be supplied with a low-pass filter on special order. The P702BF-1 is supplied with 20kHz low pass filter that gives a system response that meets MIL 740-2
Emergency Power and Recovery Solutions | Amphenol TPC Wire
Our environment consists of humidity, heat and chemicals. The Chem-Gard® 200°C product excels in each of these environments and allows one type of product throughout the site.
Heavy Equipment Sensors | Engine Management
Thermometrics Sensor Assemblies | JS8746 Harsh Environment Temperature Sensor. Thermometrics JS8746 Harsh Environment Temperature Sensor has been designed to address all aspects of temperature measurement for HVAC control systems in the container-ship market, in addition to industrial applications, such as compresors, condensing units, heat pumps, air conditioning.
Surface Microphone - PCB
Specifications - Surface Microphone Model 130B40 Acoustic 130B40 Polarization Voltage 0V (prepolarized) Open Circuit Sensitivity (at 250 Hz) 8.5 mV/Pa
Temposonics
MTS Sensors R-Series Temposonics® Linear-Position Sensors - Model RD4 Flexible Housing Option 3 Product Data Sheet, Document Part No.: 551166, Revision A 04/10, 10/11 R-Series Model RD4 Sensors Dimension References Model RD4 sensor dimension references R-SERIES RD4 SENSOR WITH SIDE CABLE ELECTRONICS CONNECTION AND ROD STYLE 'M' OR 'T'
PERFORMANCE SPECIFICATION SENSOR 6, DEGREES OF FREEDOM 7360A -XXX YYY ZZZ
7.1.1 SENSITIVITY Measured at 1g and 100 Hz for the -2 (Measured with +15 Vdc excitation) Measured at 10 g and 100Hz for the -10, -50, -200 and -500
PERFORMANCE SPECIFICATION PIEZORESISTIVE ACCELEROMETER 71M5-XXX - PCB
edved279-1 rev g document edvps71m5 revision e page 4 of 6 continued product improvement necessitates that endevco of pcb
Data Sheet R-Series V RP5 EtherNet/IP - temposonics.com
I 5 I Temposonics® R-Series V RP EtherNet/IP™ Data Sheet FREQUENTLY ORDERED ACCESSORIES – Additional options available in our Accessories Guide 551444 Position magnets 5 20 (0.79) 43 1 14 55 1 4 15 1 53 1 18° (1.65) (0.55) M5 24 (0.94) 18° 20 (0.79) 43
HDAS Series Connectors | MIL-DTL-55302 Low Mating Force Connectors ...
Amphenol reduces the pitch and increases the density of contacts with the HDAS range. With its robust and simple design, high density and high performance in harsh environments, HDAS rectangular connectors are the right high-density PCB connector when installation, cost and reliability must be considered.
HDAS Series - Amphenol Aerospace
Amphenol Socapex 948, promenade de l’Arve BP29 74311 Thyez Cedex - France Phone: +33 (0)4 50 89 28 00 [email protected] We reserve the right to modify our products in any way we deem necessary.
gs-12-1039 airmax cable assembly rev a - Amphenol CS
NUMBER GS-12-1039 TYPE PRODUCT SPECIFICATION TITLE PAGE REVISION AirMax VS® Cable Assembly 8 of 14 A AUTHORIZED BY DATE PDS: Rev :A STATUS:Released Printed: Jan 18, 2013
Vibration monitoring considerations in high EMI environments
Two primary types of shielding are available for high EMI enivornments: braided wire or foil shielding. Foil shields are typically used with high frequency signals within electronic circuitry.
Glossary of RF Terms
A. AMPS Advanced Mobile Phone System, an analog standard for wireless service. Accessories Mechanical devices, such as cable clamps, added to connector shells and other such hardware which is attachable to connectors to make up the total connector configuration.