Search Results for imb3180-24-f-v1
CXL 4-1LW/... - AMPHENOL PROCOM
Unity Gain, Broad-banded, Omnidirectional Base Station Antenna for the 80 MHz Band
KAYE - Thermal Validation System & Environmental Monitoring
15 seconds per 24 hours (0.0174%) from -45 to 140°C. Regulatory Compliance. UL, CE, Intrinsically Safe. Sensing Element Pressure. Absolute Pressure Sensor. Operating Range. 0 to 5 bar absolute (0 to 73 psia) Accuracy. Temperature Range, Accuracy >0°C to 120°C, ±25 mb accuracy
Steel CuStomer FindS Solution For torCh maChine appliCation - TPC Wire
USA 800-521-7935 • F Ax 866-528-2930 • CAnAdA 800-545-0122 • Mexi Co 001-877-283-1696 Chile 1230-020-0229 • Col oMbiA 0-1-800-915-7519 • Per U 0800-54863 • WWW.tPCWire.Com Want to learn more about tPC? Visit us at www.tpcwire.com or call 800-521-7935. Case study: extreme Temperature total savings in material and labor = $20,000
00175830102 - Amphenol Air LB
Phone +33 3 24 22 78 49. Email accueil@amphenol-airlb.fr. Categories. Products; Markets; Solutions; Know-how; Be the First to Know. Get all the latest news, Subscribe here ! Enter your email. Subscribe. I have read and I accept the privacy policy. Click here to unsubscribe from our newsletter. Support.
NF-LCF158-E01 - N Female Connector for 1-5/8" Coaxial Cable, OMNI FIT ...
Title: NF-LCF158-E01 - N Female Connector for 1-5/8" Coaxial Cable, OMNI FIT™ Premium, Straight, O-Ring and compression sealing Created Date: 2/23/2025 6:53:22 PM
ecomm.gemeco.com
{"uri":"https://ecomm.gemeco.com/api/v2/products/5fb462d0-0c87-4e68-83e5-ac3700ebc44e","id":"5fb462d0-0c87-4e68-83e5-ac3700ebc44e","productNumber":"B175C-12-L-BB ...
6.0 ± 0 - svmicrowave.com
F R E Q . R A N G E : DC to 40 GHz V S W R : 1.4:1 Max, DC to 18.0 GHz 1.6:1 Max, 18.0 + GHz I N S E R T I O N L O S S : 1.35 dB Max N O T E S 1. See individual data drawings for connector specifications 2. Dimensions shown are in inches TITLE: VITA 67.1/2 SMPM Plug-in Contact to 2.92mm
NovaSensor NPH Series Solid State Low Pressure Sensors
4. 32°F to 158°F (0°C to 70°C) with reference to 77°F (25°C). 5. 32°F to 158°F (0°C to 70°C), by design. 6. Normalized offset/bridge voltage —100 hrs, typical value, not tested in production. 7. All values measured at 77°F (25°C) and at 1.5 mA, unless otherwise noted. 8. Reduced performance outside compensation range. 9.
NTC Type NDK - amphenol-sensors.com
code NDK152C2R1 for 1500 W ±1% at 77°F (25ºC) in the range of 32°F (0ºC) up to the maximum operating temperature • Reference temperatures • Wire lengths 1.181 in to 23.62 in (30 mm to 600 mm) 0.195(±1 mm or ±2%, whichever is the greater) • Other wire materials Data • Minimum operating temperature range: -40°F to 311°F
075I99V12TN4190000R5 - Amphenol Broadband Solutions
Skip to main content. Products; Solutions; Company. News; Events; Media; Fiber 101 Training; Certifications
Receptacle SIM serie2 Monomodule Long flanged Olive drab cadmium With ...
Receptacle SIM serie2 Monomodule Long flanged Olive drab cadmium With color coding plate Polarization E
Saudi Arabia - kayeinstruments.com
Kaye ValProbe RT {Overview} Kaye ValProbe RT {Base Station} Kaye ValProbe RT {Flexible Temperature Logger} Kaye ValProbe RT {Bendable Temperature Logger}
1900ND90P2A00C - Amphenol Air LB
Connector 1900 Elio Pin Without polarizers, without contacts
PROTIMETER Timbermaster - amphenol-sensors.com
cantly above or below 20°C (70°F). The Timbermaster is switched ON by pressing momentarily and switched OFF by pressing and holding for 2 seconds or more. The instru-ment will switch OFF automatically after 5 minutes unless the default set-ting is changed (see section 3). 1 Using the Protimeter Timbermaster without the Temperature Probe
3653–37 2W/4W Transmission Only with Extended Range and Loopback (2W/4W ...
Section 365–337–201 2 1. GENERAL 1.1 Document Purpose This practice provides information on the Charles Industries 3653–37 2–Wire/4-Wire Transmission Only with Ex-
HY-TREX DEVICENET CABLE - THICK - tpcwire.com
EXPERTS IN CUSTOM CABLE AND ASSEMBLY SOLUTIONS WWW.TPCWIRE.COM Speci˜cations ubject o hange. For omplete peci˜cations nd vailability, k our TPC Sles Representative r all 800-521-7935.
Ram-Lock Connectors | Products | Amphenol Aerospace
Amphenol’s Single Pole Ram-Lock connector is a ruggedized push-pull connector designed for applications up to 500 °F (260 °C) Ram-Lock can be applied to various styles of connectors. Ram-Lock is a new mechanical interface technology for the military and aerospace markets that can be used across a variety of Amphenol product lines.
696-960 / 1695-2180 / 1695-2180 MHz - Amphenol Antenna Solutions
REV060221NA www.amphenol-antennas.com 2 o f 7 696-960 / 1695-2180 / 1695-2180 MHz HEX334CW0000 x Location of the MDCU or MDDU for RET Control (MDCU shown) Tilt indicators covered by transparent caps. Knob colors are the same as the connectors. Port A Port B
www.gemeco.com
{"uri":"https://www.gemeco.com/api/v2/products/19e13a9d-4b15-44a7-8db2-ac3700dccad1","id":"19e13a9d-4b15-44a7-8db2-ac3700dccad1","productNumber":"000-135-397 ...
MobiLed smartfit eng#2
Voltage Nominal 24 V C D Supply 18-32 V DC Power consumption Nominal 1–3 A (varies with the sign size) Data communication RS 485 EMC EU Directive 89/336/EEC and 2006/28/EG CE and e mark EN50155 Ambient environment Temperature range –30 to +70°C Relative humidity <93% RH at +40°C Shock, Vibration EN 50155:1995 EN 61373