Search Results for industrial air conditioner
Model 356A32, | PCB Piezotronics (en)
3425 Walden Avenue Depew, NY 14043. Sensorline SM 716.684.0001. info@pcb.com +1 800-828-8840
Battery Powered ICP® Sensor Signal Conditioners - PCB
Battery-powered signal conditioners offer a portable and convenient solution for powering ICP® sensors and ICP® in-line charge converters, facilitating seamless integration into any measurement chain. ... pressure, force, acoustics, load, and shock in research and development as well as industrial applications. Divisions of PCB. Subscribe.
Sensors for Research & Development | PCB Piezotronics
Modally Tuned Impact Hammers with Force Sensor, & Signal Conditioner; Pressure Sensors for Research & Development; Microphones for Acoustic Measurements; Sensors for Power Generation Equipment; ... pressure, force, acoustics, load, and shock in research and development as well as industrial applications. Divisions of PCB.
Impact and Drop Testing - PCB
conditioner. All signal conditioner output channels, which initially provide independent DC signals, are then routed to a data acquisition card where Instron’s Dynatup® Impulse data acquisition and analysis system sums and then displays the output as a time waveform. Figure 1 8150 Drop Tower Courtesy of Instron Crosshead with integral force ...
Model 624B11 Precision Quartz Industrial ICP® Accelerometer ... - PCB
The signal conditioner consists of a well-regulated 18 to 30 VDC source (battery or line-powered), a current-regulating diode (or equivalent constant current circuit), and a capacitor for decoupling (removing the bias voltage) the signal. The current-regulating device is used in place of a resistor for several reasons.
Model EX600B14 VERY HIGH TEMPERATURE Industrial ICP® Accelerometer ...
The signal conditioner consists of a well-regulated 18 to 30 VDC source (battery or line-powered), a current-regulating diode (or equivalent constant current circuit), and a capacitor for decoupling (removing the bias voltage) the signal. The current-regulating device is used in place of a resistor for several reasons.
Sensors | Products - Amphenol
i2s is your contact for the development and production of pressure sensors, temperature sensors, mass air flow sensors, as well as combination sensors for several measurements. Customers from the automotive, commercial vehicle, mechanical engineering, and metrology industries have been relying on our experience and know-how for more than 15 years.
Model 685A09 | PCB Piezotronics
Model 685A09:Linear adjust mechanical switch, 0 to 7 g’s, 0 to 100 Hz, pushbutton reset
Model 030A10 | PCB Piezotronics
Model 030A10:Miniature, low-noise, blue coaxial cable, 10-ft, 3-56 plug to 10-32 plug
Model RHM240A01 Industrial dynamic strain sensor, ICP® quartz, 100 mV ...
Industrial dynamic strain sensor, ICP® quartz, 100 mV/microstrain, +/-50 microstrain range, M6 x 1 thd, RoHS compliant Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www ...
Model 626B03 Low Frequency Industrial ICP® Accelerometer ... - PCB
The signal conditioner consists of a well-regulated 18 to 30 VDC source (battery or line-powered), a current-regulating diode (or equivalent constant current circuit), and a capacitor for decoupling (removing the bias voltage) the signal. The current-regulating device is used in place of a resistor for several reasons.
johnson controls thermostat | Amphenol Global Search | Amphenol
the de-icing of frozen pipes and valves. The 120VAC adjustable thermostat makes it easy to dial in the temperature you need up to 220°C. Our flexible silicone heating tape can be wrapped around pipes as small as 0.25” O.D. and features a plug & play design to eliminate the need for hardwiring.
General Signal Conditioning Guide - PCB
industrial hygiene standards, as well as for measurement of building acoustics, community and environmental noise monitoring, as well as supporting various automotive, aerospace and industrial applications. Toll-free 1-888-258-3222; email: sales@larsondavis.com; www.larsondavis.com Toll-Free in USA 866-684-7107 E-mail ltinfo@pcbloadtorque.com
Model 442A102 ICP® Sensor Signal Conditioner Installation and ... - PCB
ICP® Sensor Signal Conditioner Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com
Charles Universal Broadband Enclosure CUBE-SS4B231VX1 General ...
Battery Air (HVAC 2 failure) Conditioner. RTN (-) BL GY BLGY BL ON/OFF. BK W. To 120VAC 15A disconnect. LT-SS4B231VXX . Page 4 of 4 9. th. ... Maintain a minimum of 6” clearance to enable proper air flow. The CUBE includes two battery temperature probes, wired in series and connected to the power system. After installing the batteries,
Circular Connectors | Products - Amphenol
With M8x1 D coding, Industrial Ethernet transmission is implemented using a 4-pole M8x1 connector in conjunction with a 360° shielding and a standard Ethernet cable. Together with the contacts changed to 0.8 mm diameter, the connector enables a transmission rate of up to 100 Mbit/s (Fast Ethernet). ... Amphenol Air LB GmbH Ground Plane ...
Model 8159-1013A STRAIN GAGE SENSOR SIGNAL CONDITIONER ... - PCB
STRAIN GAGE SENSOR SIGNAL CONDITIONER Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com
Model EXM607A11/030BZ Platinum Swiveler® Industrial ICP® Accelerometer ...
The signal conditioner consists of a well-regulated 18 to 30 VDC source (battery or line-powered), a current-regulating diode (or equivalent constant current circuit), and a capacitor for decoupling (removing the bias voltage) the signal. The current-regulating device is used in place of a resistor for several reasons.
Model M623C01 High Frequency Industrial ICP® Accelerometer ... - PCB
The signal conditioner consists of a well-regulated 18 to 30 VDC source (battery or line-powered), a current-regulating diode (or equivalent constant current circuit), and a capacitor for decoupling (removing the bias voltage) the signal. The current-regulating device is used in place of a resistor for several reasons.
Model 444A53 Ballistic Peak Pressure Monitoring System - PCB
Ballistic Peak Pressure Monitoring System Model 444A53. The Model 444A53 is a modular-style signal conditioner that combines a dual-mode amplifier module (), a peak voltage monitoring module (444A152), and an AC power supply module (441A101) into one, integrated device.The unit connects directly with an ICP® or charge output pressure sensor, normalizes sensor sensitivity and displays peak ...