Search Results for input current
Model 6634D Signal Conditioner IM6634D - PCB
8 A-IN Input Optional input to the velocity integrator. 9 V-IN Input Optional input to the displacement integrator. 10 Not Used n/a 11 AC-OUT Output The output of the AC signal chain. 12 DC-OUT Output The RMS, Average or Peak level of AC-OUT. 13 BB-IN Input Broadband input. Output from the optional external filter.
Low Current Circuit Breaker Panel - Amphenol Broadband Solutions
Input rating 100A per feed (40A per feed with input breaker) Max. input interrupt device 125A Max. output protection device 20A Power dissipation (full load) 0.2 Watts/Amps per bus Mechanical Dimensions 17.25" W x 1.75" H x 8" D (438 mm x 45 mm x 203 mm) 12 lbs. (5.44 kg) Material Cold rolled steel Finish Black, powder coat (certain
nrgSMART™ | ANS - amphenol-ns.com
nrgSMART technology not only provides threshold alarms for current, voltage, and temperature, notifying you of issues BEFORE fuses or breakers trip, it reports current per individual circuit, total input bus current, as well as panel input voltage and data from external temperature probes.
Multi-purpose Signal Conditioners - PCB
Adjustable ICP® current; Optional input filtering; MCSC Control Software. Signal conditioners equipped with an RS-232 or Ethernet interface come bundled with PCB's Multi-Channel Signal Conditioner control software. This user-friendly software presents a comprehensive table detailing the current settings for each channel of the unit. Users can ...
High-Current Demarcation Panel - Amphenol Broadband Solutions
High-Current Demarcation Panel Power :: Four Circuit Breaker Positions up to 100A Each, 100A Input per Bus Ordering Information Specifi cations Part Number Description 009-7000-0104 High-current demarcation fuse panel Circuit Breakers Circuit breakers include 1 breaker and 1 mounting faceplate kit. 090-0052-0001 1A 090-0052-0002 2A 090-0052 ...
1RU 250A DUAL-FEED, 8/8 TPA FUSE PANEL
Panels are available in high current input 8×8 circuit breaker or TPA fuses, mid-current TPA/circuit breaker/GMT combinations, and low current 10×10 GMT and 15×15 GMT variations. Need Some Power Intel? Panels are available with standard alarming via output contacts or with nrgSMART per-circuit current monitoring.
MODEL 2221 FOR LOW NOISE AND 200 V MICROPHONES PREAMPLIFIER - PCB
DC Input Voltage 10.5 to 30 V DC Input Current 65 mA @ 12 V with PRM902 Input Connector PIN SIGNAL 1 No connection 2 Signal ground 3 Microphone polarization voltage 4 Signal Input 5 No connection 6 Power Supply (+18 V) 7 Power Supply (-18 V) Shell Connected to case ground SPECIFICATIONS (continued) Physical Dimensions (H x W x D) 8.02 x 4.10 x ...
Input Output | Connectors | Amphenol
Input Output; Input Output. Filter. Filter. Apply Filters Reset All. View as List Grid. Results 1-24 of 110. Page. You're currently reading page 1; Page 2; Page 3; Page 4; Page 5; Page Next; ... HYBRID D-SUBMINIATURE CONNECTORS Mating interface according to MIL C24308 Current rating of 7.5A for... DETAILS. D-Sub Dual Port Connectors ...
350A Dual-Feed High-Current Panel - Amphenol Broadband Solutions
Each of the 350A feeds are totally isolated, providing power to six high-current and five low-current positions. A replaceable alarm card contains power and alarm LEDs for sides A and B. Key Benefits • High-current capabilities — two 350A inputs • High-power distribution – six 125A single-pole positions per input
INSTALLATION INSTRUCTIONS C-CHARGER & OWNER’S MANUAL - Charles Industries
Maximum current permitted from the STATE output is 0.05 Amps. 14 LIM NO If connected to battery voltage, the regulator is duty-cycle-current limited at the setting of potentiometer R11 (see Figure 1). 15 EQL NO This input is used to select either the regulator’s equalization mode or a second duty cycle current limit, depending on internal ...
LÜTZE Converters
Input protection Describes the protection measures taken and indicates the maximum possible input signal. Suppressor diodes are mostly used to limit voltage and PTC resistors to limit current. Input resistance To ensure low load on the input signal, current inputs are always executed as low-resistance and voltage inputs as high-resistance:
HVSLS600023A1H6 | Amphenol Global Search | Amphenol
part number: HVSLS600023A1H6. datasheet: view / download. specifications: connection: bus bar. current: 120A. Dual Temp and Vibration Output. Reciprocating Machinery ...
4-20 mA configurable vibration transmitter module
INPUT IEPE sensor type Temperature sensor input Single-ended, DC coupled 10 mV/°C IEPE power source +24 VDC, 4.5 mA Sensitivity range: acceleration velocity 9 - 11,000 mV/g 9 - 11,000 mV/ips Full scale input range ± 10 VDC Frequency response Fmax options 0.2 - 20 kHz (-3 dB, -0.1 dB) 200, 500 Hz; 1, 2, 5, 10, 20 kHz Accuracy ± 0.2% of full ...
AMP Centro | Amphenol Global Search | Amphenol
Enter the information below to calculate the ampacity for the selected wire gauge and given conditions. 1. DC Current Input Data. 2. Output Details. 3. Calculated values for the Selected thickness. 4. Selected values. 4 (A). Skin Effect for AC High Frequency. 5. DCR @ 20C. 5A. AC Resistance @ 20C at High Freq. 5B. For thickness t 2SD. 6.
Amphenol Network Solutions > HIGH CURRENT
Each of the 350A feeds are totally isolated, providing power to six high-current and five low-current positions. A replaceable alarm card contains power and alarm LEDs for sides A and B. FEATURES • High-current capabilities - two 350A inputs • High-power distribution - six 125A single-pole positions per input
Model 421B31 | PCB Piezotronics
[4] Output can be set to either current or voltage output depending on the wiring configuration. See manual for wiring configuration. [5] Frequency response tested with 1000pF input capacitor. [6] Set to provide a 100 mV/g or 100 µA/g output when using a 10 pC/g accelerometer.
Model 480E09 1-Channel, battery-powered, ICP® sensor signal ... - PCB
internal electronics which provide regulation for approximately 2.6 mA of constant current power. Connections include two BNC jacks, one for Sensor (ICP® power/input) and one for Scope (output to scope, data recorder, or DAQ). The front panel meter indicates the voltage output when connected to a sensor and is color coded for
10-70500-22 | Amphenol Global Search | Amphenol
Search Results for 10-70500-22. Developed in the 1980’s to provide solutions to problems caused by the high mating and unmating forces of conventional pin and socket contact pairs. 4 Body styles: mother board (MB), daughter board (DB), PC connector, input/ output connector.
Strain Gage Signal Conditioner - PCB
Switch Positions for Input Signal Range Adjustment Series 8162 Performance English SI Input Signal (sensor sensitivity) 0.5 to 11 mV/V 0.5 to 11 mV/V Output Signal [1] (voltage) ± 5 VDC or ± 10 VDC ± 5 VDC or ± 10 VDC (current) 4 to 20 mA 4 to 20 mA Frequency Range [2] 0 to 1000 Hz 0 to 1000 Hz Electrical Filter Cutoff Frequency [2] 100 Hz ...
LOCC-Box LUTZE Overload Current Control
input capacities. Furthermore, hazardous overcurrents must be reduced to a safe level within 5s. Rating is made more difficult by the fact that nowadays many parallel con-sumers are supplied by way of one protection element. LÜTZE LOCC-Box – the intelligent current monitoring system Figure 2: LOCC-Box single module