Search Results for input current
Low- frequency vector sensor VS-301 - Wilcoxon Sensing Technologies
Full scale input range: Accelerometer Hydrophone 0.5 g pk 600 Pa pk Frequency response, ± 3 dB: Accelerometer 0.2 Hz Hydrophone 6.0 Hz 3.0 Hz - 2.0 kHz 3.0 Hz - 2.0 kHz Transverse sensitivity, max <5% Temperature accuracy ±1.0° C Power requirement: Voltage Current, nominal 6.5 - 9.0 VDC 40 mA
550824K M Series MH Analog Data Sheet - Temposonics
MTS Sensors M-Series Model MH, Temposonics® Linear-Position Sensor - for Mobile Hydraulics 5 Analog Output - Product Data Sheet, Document Part No.: 550824, Revision K 01/12, 05/12, 08/12 Model MH Rod-Style Sensor Connections, Wiring and Mounting Connections and wiring CONNECTION TYPE The Temposonics® M12 connector system (shown in Figures 7, 8, 9 and 10 ), meets the most stringent protection ...
WST7B3 power amplifier Operating guide - wilcoxon.com
control current is determined by the source equipment. The carrying current of the “OUT” relay is 2 Amps. The amplifier’s control circuitry itself draws less than 2mA from the control current when operating. 2.0 Operation of the power amplifier Wilcoxon Sensing Technologies manufactures a comprehensive line of vibration generating systems,
XMAPD10-1-4-8S - XMA
Our power dividers split input signals into two more identical output signals. XMA is ready to double (or even octuple) your input signal. See our offerings below, and let us know if you don't see your ideal solution. ... CURRENT STOCK Out of Stock. View Distributor Website. Microwave Components LLC 800-282-4771 admin@mwc-llc.com https://mwc ...
3082-6524-dB - XMA - xmacorp.com
Adapters. Maintaining input power with high signal integrity; Power Dividers. Splitting power input to identical outputs; ... CURRENT STOCK Out of Stock. View Distributor Website. East Coast Microwave Sales and Distribution, LLC 800-786-2576 sales@ecmstockroom.com www.ecmstockroom.com.
Model RH401B04 - PCB
frequency response of systems with long input cables. (The Model 401B04 simulates the circuit of an ICP ® sensor while the signal generator takes the place of the sensor’s crystals.) 2. INSTALLATION AND OPERATION CAUTION: Connect the output only to an ICP ® type, current-limited signal conditioner. WARNING: Excessive current may damage this ...
psas | Amphenol Global Search | Amphenol
Amphenol's Cool Express Link™ comprises a series of EDSFF E3 2C Hybrid Orthogonal Press-fit PCIe ® Gen 5/6 cable connectors that facilitate low-latency, high-bandwidth, and high-throughput data transmission for both current and next-generation storage solutions, including CXL 3.1 applications.
MICROPHONE PREAMPLIFIER - pcb.com
Constant Current Excitation 2 to 20 mA 2 to 20 mA Impedance(Input) 2x1010 Ohm 2x1010 Ohm [1] Capacitance(Input) 0.15 pF 0.15 pF [1] Output Bias Voltage 10 to 14 VDC 10 to 14 VDC Impedance(Output) < 50 Ohm < 50 Ohm Output Voltage(Maximum) ± 8 Vpk ± 8 Vpk [1] Physical Housing Material Stainless Steel Stainless Steel Size - Diameter 0.25 in 6.4 mm
Model 352A26 | PCB Piezotronics
Constant Current Excitation: 2 to 20 mA: 2 to 20 mA: Output Impedance: ≤200 Ohm: ≤200 Ohm: Output Bias Voltage: 9 to 16 VDC: 9 to 16 VDC: Discharge Time Constant: 0.24 to 1.0 sec: ... Scope input adaptor (10-32 jack to BNC p... $52.00 USD (Pricing valid only in the U.S.) Add to Cart. Model: 480C02. Platinum Stock Products; 1-channel, batt...
240GMT54/nrg240GT54 240A Dual-Feed Combination Fuse Panel
from the panel, or vertical feed inputs and output connectors that allow input cables to be routed directly from above and speed up installation of outputs • Optional Individual Circuit Monitoring provides high accuracy, 100% passive monitoring • Collect voltage and current for both feed and output circuit
0140 | Amphenol Global Search | Amphenol
MPS02-BSFA032S is a 32-pin low voltage signal connector with IP68/IP6K9K waterproof rating and 15A current rating. It is used for automotive and military applications and has various specifications and dimensions. ... Retimer compensate for non-linear PCB trace and cable loss to 40 inches of FR4, eliminates input Random Jitter (Rj ...
Model PRM 831 - PCB
Input Impedance 10G Ω ... Power Supply Current 1.9mA Typical Temperature Sensitivity < ± 0.05 dB (-40deg to 176 deg F) -40 deg to 80 deg C Humidity Sensitivity < ± 0.05 dB (0-90% RH) Non-condensing @122ºF Dimensions 0.5”dia x 2.88”L 12.7mm dia x 73mm L
Part No. 550033 Rev. E
Input Voltage: – 12 to – 15 Vdc Current Draw: Transducer Only: – 15 Vdc at 100 mA maximum, 25 mA minimum (current draw varies with magnet position, maximum draw occurs when magnet is at 2 in. (50.6 mm) from the flange and minimum update time is being utilized) Transducer with: RS-422 Personality Module (RPM):
2 Sensor for Automotive Applications - Amphenol
Input Voltage: 9VDC - 16VDC LINbus Voltage: 9VDC - 40VDC Current Consumption • Active Mode Current (average): 20mA • Low Power Mode Current (average): 15mA • Sleep Mode Current (no measurement): 25uA • Peak Current (max): 120mA. 3 Cable and Connector Connection Mating Connector TE AMP 4-1718346-1
OS2020-6616-06 - XMA
Adapters. Maintaining input power with high signal integrity; Power Dividers. Splitting power input to identical outputs; ... CURRENT STOCK Out of Stock. View Distributor Website. East Coast Microwave Sales and Distribution, LLC 800-786-2576 sales@ecmstockroom.com www.ecmstockroom.com.
PRO-DIPX 1000/1550-... XS - AMPHENOL PROCOM
DC pass max. current: DC pass LOW port to ANT port : 1 A (Applies only to certain models. See Ordering) DC pass HIGH port to ANT port : 200 mA (Applies only to certain models. See Ordering) ... The main tasks of the diplexer are to protect the individual receiver input from being destroyed by the transceiver in the contrary band and to ensure a ...
Model 426A13 | PCB Piezotronics
Constant Current Excitation: 2 to 20 mA: 2 to 20 mA: Impedance (Input) 20000000000 Ohm: 20000000000 Ohm [1] Capacitance (Input) 0.2 pF: 0.2 pF [1] Output Bias Voltage: 10 to 14 VDC: 10 to 14 VDC: Impedance (Output) 50 Ohm: 50 Ohm: Output Voltage: ±8 V: ±8 V [1] Physical: Housing Material: Stainless Steel: Stainless Steel
Minitek® Pwr 5.7 | FCI Basics | Wire To Board Connectors | High Current ...
FCI Basics Minitek® Pwr 5.7 is a flexible and comprehensive solution for power application with a high current rating up to 23A per contact and wire gauge range from 16AWG-12AWG for wire-to-board application. ... Input Output. OverPass. Power. Cables on Demand. Optics Solutions. High Speed I/O Solutions. New Products. Custom Products. By ...
BlueSolar MPPT 100/30 - Gemeco
Up to 100 Volt input voltage, up to 30 Amps output Terminals can accommodate wire up to 6 awg. Provides three stage temperature compensated charging with a flexible charge algorithm; Over-temperature protection and power de-rating when temperature is high. Maximum efficiency 98%; Dimensions 130 mm x186 mm x 70 mm (Approx 5.1" x 7.3" x 2.7"
DesignCon 2024 | Education Day | Meet Amphenol at Booth #833
Input Output. D-Subminiature. DisplayPort. HDMI. High Speed I/O. Industrial Ethernet. Lighting. Modular & Magnetic Jack. Commercial Rugged Harsh I/O. USB. Server & Storage System. Card Edge. ... University of L’Aquila - Enhancement of current PCB technology and design to enable 200 Gbps signaling.