Search Results for input current
M6203 SERIES - Amphenol Aerospace
DC Input Normal range: 220-350VDC Wider range possible DC Output Voltage range: 3.3 to 50 VDC Current range: 0 to 30 A Power range: 0 to 500 W Isolation Input to Output: 500 VDC Input to Case: 500 VDC Output to Case: 200 VDC Output Voltage Regulation: Better than ±1% (no load to full load, –55°C to +85°C and over input voltage range ...
nrgSMART™ Technology Archives - Amphenol Broadband Solutions
Products with nrgSMART™ Technology monitor current at the individual circuit level, providing detailed information not available with feed-level monitoring or threshold-alarming like most other monitoring panels on the market. nrgSMART™ Technology not only provides threshold alarms for current, voltage, and temperature, notifying you of issues BEFORE fuses or breakers trip, it reports ...
350A Dual-Feed High-Current Panel - amphenol-ns.com
Each of the 350A feeds are totally isolated, providing power to six high-current and five low-current positions. A replaceable alarm card contains power and alarm LEDs for sides A and B. Key Benefits • High-current capabilities — two 350A inputs • High-power distribution – six 125A single-pole positions per input
M1326103 Series - amphenol-aerospace.com
The inrush current limiter circuit limits the initial charge-up current of the inter-stage bulk capacitance. 5 The high power factor AC/DC converter shapes the average input current draw, by changing the inter-stage output voltage in synchronization with the momentary input voltage, input current and output current.
M4071 Series - amphenol-aerospace.com
Input Inrush Current Limiter Under Voltage Lock-Out Unit shuts down when input voltage is below 90 Vac. Output Active Over-Voltage Threshold set at 110% ± 5% of nominal voltage. Passive Over-Voltage Threshold selected at 120% ± 10% of nominal voltage. Overload / Short-Cicuit Protected against indefinite short circuit by a hiccup mechanism
M7318 SERIES - amphenol-aerospace.com
DC Input: 18 to 48 VDC Turn on Transient: No overshoot. DC Output: Voltage range: 3.3 to 50 VDC Current range: 0 to 18 A Power range: 0 to 200 W Isolation: Input to Output: 200 VDC Input to Case: 200 VDC Output to Case: 100 VDC Transient protection: IAW MIL-STD-1275A, M-STD-704A (no operation, no damage) Efficiency: Typical: 84% (at 28VDC out-put,
Universal Transmitter - PCB
Delivers Current and Voltage Output Signals Offers Two Set Points with Form A Relay Outputs (2 amp AC, 1 amp DC) Fully Programmable via Detachable Pushbutton Display ... It accepts a variety of sensor input signals and provides exci-tation voltage for two-wire, loop-powered sensors and transmitters.
CF-02EM9203 - amphenol-aerospace.com
• Clean sine-wave input current – less than 3% harmonic current. • Full-load Power Factor (PF) of above 0.98. • Inrush current limiting. • Conduction cooled via the baseplate. • Inhibit Input, BIT and Current Monitor outputs. • Overload, Overtemperature, Overvoltage and Missing-phase • protections.
Power Card Edge Connectors | PSU Connector - Amphenol CS
The EnergyEdge™ product series features twice as many contact points allowing for a 25% improvement in linear current density when compared to existing card edge products. Discover the highest density card edge series on the market! ... Input Output. D-Subminiature. DisplayPort. HDMI. High Speed I/O. Industrial Ethernet. Lighting. Modular ...
4-20 mA vibration transmitter modules iT150 series
Input/Output type “A” only. ** Displacement output option available for Input type “V” only. iT150 Input type A Acceleration V Velocity Sensitivity 10 100 mV/g, mV/ips 500 Detector type RMS True RMS P Peak (equiv.) PP Peak-to-peak (equiv.) TP * True peak (10-25,000 Hz) Output type A Acceleration V Velocity D** Displacement Units g g ips ...
TECHNICAL NOTE TN-17 - PCB
operate through low-noise cable into a high input impedance charge amplifier, which converts the charge signal into a usable low-impedance voltage signal for acquisition purposes. The charge ... constant-current power source over a two-wire circuit with signal/power carried over one wire and the other wire serving as ground. The cable can be
HVSLS600023A1H6 | Amphenol Global Search | Amphenol
part number: HVSLS600023A1H6. datasheet: view / download. specifications: connection: bus bar. current: 120A. Dual Temp and Vibration Output. Reciprocating Machinery ...
AMP Centro | Amphenol Global Search | Amphenol
Enter the information below to calculate the ampacity for the selected wire gauge and given conditions. 1. DC Current Input Data. 2. Output Details. 3. Calculated values for the Selected thickness. 4. Selected values. 4 (A). Skin Effect for AC High Frequency. 5. DCR @ 20C. 5A. AC Resistance @ 20C at High Freq. 5B. For thickness t 2SD. 6.
High-Current Demarcation Panel - amphenol-ns.com
High-Current Demarcation Panel . Installation Guide . Applies to: 009-7001-0104B & 009-7001-0104B-TFD. 009-7001-0104B-TFD . ... With the input power off, firmly install the circuit breakers or fuse holders in the panel. As shown in Fig. 3, install the TFD fuse holders and bezel(s):
ms27506 | Amphenol Global Search | Amphenol
-C22.2 No. 107.1-01 for general use power supplies and features 300 W of maximum power, 52 V of DC output and a maximum current input of 10 A. Amphenol’s connectors and junction boxes offer the highest voltage and current ratings in the PV market.
ex40202d | Amphenol Global Search | Amphenol
20 30 40 50 60-100 200 500 800 1100 1400 1700 2000 Angle (deg) Torque (Nm) Post Yield Zone . PCB LOAD & TORQUE, INC. 24350 Indoplex Circle, Farmington Hills, MI 48335 USA Phone: 866-684-7107 Fax: 716-684-0987 Email: ltinfo@pcbloadtorque.com www.pcbloadtorque.com
CF-02EM6242 - Amphenol Aerospace
Input Output Voltage Input Range Voltage Frequency Current CF-02EM6242 18 to 36 VDC 115 VAC 400Hz 1 A The M6242 Series DC&AC Inverter is a compact, high-efficiency inverter designed for reliable power conversion. It features a wide input range and ensures robust input/output isolation. The inverter includes
Automotive Interconnects | ADAS | EV Charging | Automotive Lighting ...
Connectors are typically used to connect sensors, actuators, and other components that make up the Advanced Driver Assistance System (ADAS). These connectors must be able to support high-speed data transmission, withstand vibration and temperature fluctuations, as well as provide superior electrical performance and EMI protection, and meet the stringent requirements of the automotive ...
nrgSMART CTRL / SENS - amphenolbroadband.com
to the circuit level. Reporting of voltage, panel input current, individual circuit output current, and remote temperature provide insights into conditions before alarms are triggered. Deep alarming capabilities allow four threshold points (two “high” and two “low”) per parameter, per circuit. For simplicity, thresholds can
M2701 Series - amphenol-aerospace.com
• Wide input range • Input / Output Isolation • Inrush Current Limiter • Fixed switching freq. (250 kHz) • External Inhibit • EMI filters included • Non-latching automatic recovery protections: o Short-circuit. o Over-temperature. DESCRIPTION: The M2701 military power supply is a rugged 3 phase AC to DC converter. It accepts a 115 AC