Search Results for jtng06rt-10
Model TLD208C03 | PCB Piezotronics
10-32 Female * All specifications are at room temperature unless otherwise specified. Accessories. Supplied: 080A81: Thread lock adhesive (for Series 200) 1: 084A03: Impact cap, convex (for Series 208) 1: 081B05: Mounting stud, 10-32 to 10-32, 0.275" long, BeCu w/shoulder: 2: M081A62:
MS, 97 AND 97B SERIES - Amphenol In
Note - Both versions, straight and diamond knurling available on coupling ring. For details, contact factory. BACK | NEXT | NEXT
Base Station Antennas from Amphenol Antennas
High performance antennas for virtually all applications and frequencies. Plus options to boost capacity in high traffic areas or cover hard to reach sites.
PCB Search Results (Adapter)
For use with either 10-32 or 1/4-28 reference standards. Product Datasheet. Model: 9155-MNT43. Calibration System Mounting Adapter for sensors with 1/4"-18 NPT integral stud to 1/4-28 male for Modal Shop portable vibration calibrators. Product Datasheet. Model: 9155-MNT74.
B744VL 50/200kHz, 600W, Long Stem w/ FB, Garmin 8-Pin, DST - Gemeco
600 W. The B744VL is a TRIDUCER ® Multisensor featuring depth, speed, and temperature in a single housing. The 50/200 kHz, dual-frequency, single, ceramic element provides great target detail in shallow water at 200 kHz and good deep-water bottom tracking at 50 kHz.
Item # NX307CB1B, Push-Button Switches with Contact 7
10 Amps at 28 VDC (Resistive Load) 5 Amps at 28 VDC (Inductive Load) 3 Amps at 28 VDC (Lamp Load) Type 7 Contact Arrangement: 150 to 4500 : Mechanical Life: 500,000 Cycles : Plunger: Glass filled nylon : Plunger Travel.085 inch (approx.) Action: Momentary : Operating Force: 3 to 5 lbs :
Application Note - Amphenol Industrial Operations
Ahe BACKGROUND Key Oil & Gas OEM’s require an ATEX rated explosion proof cable sealing solution that can be used for termi-nating hard-wired and connector solutions alike.
Assembly - Amphenol Sine
Insulation resistance IEC 60512-3-1 >1010 Ohm2) Contact resistance IEC 60512-2-1 <5mOhm Climatic category IEC 60668-1 40 / 100 / 21 Temperatur range-40°C...+100°C / -40°F...+212°F IP degree ÎEC 60529 IP 68 (in mated condition) Insertion and withdrawal force IEC 60512-13-2 25N 30N 35N 35N 50N 55N 55N 60N 50N 50N mechanical operation IEC ...
Charles Industries, LLC
Created Date: 10/31/2005 12:47:52 PM
Mini Cool Edge IO Connector System - Amphenol
Mini Cool Edge IO is an internal flyover connector system used in server, storage and data centers. Internal flyover is a trend that supports design flexibility and reach for high data rate signals inside the box. With a 0.60mm signal pin pitch and curren
PCB® General Purpose High Frequency Response Pressure Sensors for ...
PCB ® manufactures sensors used by design engineers and predictive maintenance professionals to test and measure vibration, pressure, force, acoustics, load, and shock in research and development as well as industrial applications.. Divisions of PCB
ICP INFRASOUND MICROPHONE SYSTEM Revision: E - PCB
Output Bias Voltage 10 to 14 VDC 10 to 14 VDC Maximum Output Voltage ±7 Vpk ±7 Vpk Output Impedance <50 Ohm <50 Ohm Physical Housing Material Stainless Alloy Stainless Alloy Venting Rear Rear Electrical Connector BNC Jack BNC Jack Mounting Thread(Grid) 0.5 -60 UNS 0.5 -60 UNS Size (Diameter x Height)(with grid) 0.52 in x 4.29 in 13.2 mm x 109 ...
Chirp-ready Marine Sensing Solutions - Airmar
In contrast, Chirp (compressed high-intensity radar pulse) uses a precise sweep pattern of many frequencies within a long-duration transmit pulse from a broadband transducer, so the equivalent sound energy transmitted into the water is 10 to 1,000 times greater than a conventional marine fishfinder.
Item # NX307BB1R, Push-Button Switches with Contact 7
10 Amps at 28 VDC (Resistive Load) 5 Amps at 28 VDC (Inductive Load) 3 Amps at 28 VDC (Lamp Load) Type 7 Contact Arrangement: 150 to 4500 : Mechanical Life: 500,000 Cycles : Plunger: Glass filled nylon : Plunger Travel.085 inch (approx.) Action: Momentary : Operating Force: 3 to 5 lbs :
SAFETY DATA SHEET NITRATEST TABLETS - Protimeter
10.2. Chemical stability Stability Stable under the prescribed storage conditions. 10.3. Possibility of hazardous reactions Possibility of hazardous reactions No data available. 10.4. Conditions to avoid Conditions to avoid There are no known conditions that are likely to result in a hazardous situation. 10.5. Incompatible materials
Amphenol Corporation - Stock Information
Chart the performance of an investment in APH relative to market indices or to another stock over time
Assembly - Amphenol Sine
Insulation resistance IEC 60512-3-1 >1010 Ohm2) Contact resistance IEC 60512-2-1 <5mOhm Climatic category IEC 60668-1 40 / 100 / 21 Temperatur range-40°C...+100°C / -40°F...+212°F IP degree ÎEC 60529 IP 68 (in mated condition) Insertion and withdrawal force IEC 60512-13-2 25N 30N 35N 35N 50N 55N 55N 60N 50N 50N mechanical operation IEC ...
Guidelines for Mounting Test Accelerometers | PCB Piezotronics
Stud mounting is recommended if the accelerometer has an integral stud or if it has a tapped hole and is supplied with a removable stud. This mounting method provides a very secure attachment for the accelerometer to the test structure and matches the mounting configuration during factory calibration.
Home | Amphenol Network Solutions
Amphenol Network Solutions is a leading provider of innovative connectivity solutions for MSO, OEM, MTU and Hyperscale Data Centers and Telecommunication networks. Explore our wide range of high-performance products, including fiber optic distribution, power distribution, cable management solutions, cable enclosures, optical passives, and network racks.
10166409-F32210CLF|FlexLock™ 2.54mm|Amphenol
10166410-W32000CLF. FlexLock™ 2.54mm, 2.54mm Pitch, flex-to-wire connector, USCAR-2 V2 compatible, 32pin Cable housing, C Coding