Search Results for laser marking
Charles Multi-Purpose Housing (CMPH Interconnect (IT) Series of ...
nor use a magnifier in the presence of laser light or radiation. Always exercise caution when installing, testing, or performing maintenance on live circuits. If eye exposure to laser light or radiation has occurred or is suspected, immediately seek medical treatment by a professional eye care physician.
Signal Conditioning Basics | PCB Piezotronics
In addition to ease-of-use and simplicity of operation, ICP ® sensors offer many advantages over traditional charge output sensors, including: 1.) Fixed voltage sensitivity independent of cable length or capacitance. 2.) Low output impedance (<100 Ohms) allows signals to transmitted over long cables through harsh environments with virtually no loss in signal quality.
M24308 - Positronic The Science of Certainty
The M24308 connector is a particular type of military connector standard, sometimes termed MIL-DTL-24308 and formerly known as MIL-C-24308 and MIL-PRF-24308.
Industrial & Renewable Energy - Connor Manufacturing
Corporate Headquarters Connor Manufacturing, Inc. 22867 NE Townsend Way Fairview, OR 97024 ConnorCorporate@ConnorMS.com Corporate Administration Offices Connor Manufacturing, Inc. 500 Park Blvd., Suite 820 Itasca, IL 60143 Phone +1-630-363-3300 Sales@ConnorMS.com Asia Administration Offices Connor Manufacturing (Asia) Pte. Ltd. 2 Venture Drive Vision Exchange #24-01 to #24-32
Layered Fiber Demarcation Box Installation Instruction
Danger: Direct eye exposure to laser light will cause serious eye damage. Avoid looking directly into an optical fiber, optical connector or optical adapter that is connected to an active source. Warning: Wear safety glasses to prevent accidental eye injury. Wear protective gloves and clothing to prevent accidental injury.
M29504 14 & 15 | Fiber Optic Termini - Amphenol Fiber Systems ...
The M29504/14 & 15 fiber optic termini provide superior optical & mechanical performance & are compatible w/ M28876 & comparable military-style connectors
2001-61XX-0X-DF - Sheet1 - XMA Corp
marking part looks like product image above. part marking orientation and format as shown. marking to be as large as possible, clear and readable. yyww equals date code. no chain chain part number description item no. 2001-61xx-0x-df termination, sma-m, dc-26.5 ghz 1 - ta-2001-6000-0xyy-dfu assembly, termination, sma-m, dc-26.5 ghz, unmarked 1
an - PCB
12 The marking of the equipment or protective system shall include informations as detailed at 15. Fontenay-aux-Roses, le 30 janvier 2008 SPHER Le respo sable de certification ATEX Ve AT certification manager LU tA 1826 I Oft( 7 dans son integralite, sans aucune\nodification and without any change Page lsur2
Accelerometer Adhesives | PCB Piezotronics
Accelerometer Adhesives. Many accelerometer adhesives have been successfully used for securing mounting bases to test objects. These include epoxies, waxes, glues, gels, and dental cement.
Fiber Optic Cable Guide
Fiber optics operate under a similar principle. A powerful light source such as a laser coupled with a precision crafted fiber optic cable assembly can drive a signal for several miles without the need for a booster. The theoretical bandwidth limitations of fiber optics are nearly infinite. In fact, present day fiber optic cable technologies ...
Amphenol
2 AX221058S Sensor Specifications 2. Operating Conditions Parameter Min Typ Max Unit Operating Temperature Range -40 - 95 °C Humidity 0 - 95 % Vibration1 - 2.0 - GRMS 1.
CUSTOMER OUTLINE DRAWING - amphenolrf.com
b. marking: packaging to be marked "amphenol rf, 36800 yyww, 5a 500v" 5. cable assembly instructions: a. trim cable as shown. b. slide ferrule onto the cable. c. when crimping contact pin to cable, crimp with amphenol tool 227-944 (m22520/5-01) and die set 227-1221-11,
U' GROUP IM CSA Certificate of Compliance - PCB
Certificate: 2033214 Project: 80020282 C U' CSA GROUP TM Master Contract: 184981 Date Issued: 2019-12-19 - Submittor Identification - Model Number - Serial Number, Date Code or Month and Year of Manufacture - Electrical Rating - Hazardous Location Designation (ie Ex nL IICT4, AEx nA TICT4, Class I, Div. 2, Groups A, B, C and D) (In addition to these required markings, the following optional ...
Thermal Validation - Amphenol Sensors
Thermal Validation Kaye The Kaye product range is relied upon by the world’s leading pharmaceutical and biotechnology companies to validate and monitor critical assets and processes, such as sterilization, as required by governing regulatory bodies. Kaye products are designed to meet the most demanding requirements for process improvement, thermal validation and environmental monitoring ...
SMA Panel Mount Jack 4-Hole Flange Round Post 50 Ohm
RF Connector SMA Panel Mount Jack 4-Hole Flange Round Post 50 Ohm
Wire and Cable Certifications Explained
The majority, if not all electrical wire and cable sold, will have specific ratings and/or certificates to define its intended use while providing end-users with a level of confidence in the cable's safety and reliability.
100Gb/s QSFP28 Transceivers | Optical Interconnect | Amphenol
Amphenol’s 100G QSFP28 optical modules include SR4, AOC, AOC break out, CWDM4, LR4, ER4 Lite, ER4 and ZR4 series, which adopt LC or MPO optical ports
OSFP – Defining a New Standard for High-Speed Connections
Amphenol’s OSFP product portfolio offers customers a comprehensive and integrated link solution that features DAC copper cables, AOCs, stacked and ganged board connector and cage solutions.
Coaxial Cable Installation Instruction - RFS Technologies
Insert the inner conductor into the corresponding hole of the flare tool (Marking 1/2”-C02), make sure that the flaring pin is located between outer conductor and foam/dielectric (in the free space made before). Keep pushing the back nut to the front while pressing the tool slightly and turn it a few times clockwise to flare the outer conductor.
CUSTOMER OUTLINE DRAWING MIL-C-39012 INSPECTION - Amphenol RF
b. marking: bag to be marked "amphenol rf, 31-2253, and date code" mil-c-39012 inspection 4. recommended cable assembly instructions: a. trim cable as shown. b. slide ferrule onto cable. c. crimp cable center conductor to contact with amphenol tool 227-944 (m22520/-01) and die set 227-1221-11, cavity 'b' (m22520/5-11, closure 'b')