Search Results for linear regression of data matlab
Temposonics
I2 I Temposonics® MH-Series MH4 MH200 Analog/Digital Data Sheet 1. Product description and technology Temposonics® sensors can be used in versatile mobile machines without any restriction and replace contact-based linear sensors like potentio- meters. Highly dynamic systems are controlled safely by means of Temposonics® sensors, thus enhancing the productivity, availability and
Safety Manual for MH-Series with CAN Safety (Document part number 552177)
Likewise, printed data sheets will differ from digital formats and languages will vary with geographic markets. All of those changes will be limited to graphical layout, supporting images, contact information etc. The technical data given will always adhere entirely to the content of this document. 2. Intended use of product
Data Sheet GTE Analog - temposonics.com
Data Sheet GTE Analog Magnetostrictive Linear Position Sensors. 2 5 3 1 2 4 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter
Model 3741F122G | PCB Piezotronics
Phase and Magnitude calibration from 0.5 Hz to 5% pt Linear scale for 3711 3713 DC Accels only: 1: 081A103: 4-40 threaded black-oxide alloy steel socket head cap screw with stainless steel washer (for series (for series 3741, 354x04/05) 2: M081A103
Temposonics® E-Series ET Position Sensors
Fluid Power & Linear Actuators Hydraulics & Pneumatics; Linear Motors & Actuators; Automation & Assembly Factory Automation; Tools: Wood and Metal Assembly ... Data Sheet 551676 E: EN Operation Manual 551677 G: EN Operation Manual 551677 E FR 3D Model ...
Data Sheet Level Plus - Temposonics
Data Sheet TECHNICAL DATA Level output Measured variable Product level and interface level Output signal/protocol Modbus RTU, DDA, Analog (4…20 mA), HART® Order length 1575…22000 mm (62…866 in.) (order length equals the measurement range plus the inactive zone / contact factory for longer lengths) Inherent accuracy ±1 mm (0.039 in.)
10114831-10106LF | Amphenol Global Search | Amphenol
Search Results for 10114831-10106lf. dip-306 | Amphenol Global Search | Amphenol S3 is a DIP switch that adjusts attenuation from 0 to 1.5dB in 0.1dB increments.
Temposonics
Data Sheet TECHNICAL DATA Output Interface SSI (Synchronous Serial Interface) Data format Binary or gray Data length 24, 25 bit Data transmission rate 70 kBaud*…1 MBaud, dependent on cable length: Cable length < 3 m < 50 m < 100 m < 200 m < 400 m Baud rate 1.0 MBd < 400 kBd < 300 kBd < 200 kBd < 100 kBd Measured value Position
Temposonics
The absolute, linear position sensors provided by MTS Sensors rely ... Data transmission rate 70 kBaud*…1 MBaud, dependent on cable length: Cable length < 3 m < 50 m < 100 m < 200 m < 400 m Baud rate 1,0 MBd < 400 kBd < 300 kBd < 200 kBd < 100 kBd Measured value Position
550824K MH Series MH Analog Data Sheet0613 - Temposonics®
MH-Series Model MH, Temposonics® Linear-Position Sensor - for Mobile Hydraulics Analog Output Product Data Sheet, Document Part No.: 550824, Revision K 1/12, 5/12, 8/12, 12/12, 6/13 (US) 2 Product specifications Parameters Specifications OUTPUT Measured variable: Linear Position measurement Resolution: Range: Resolution: 50 to 500 mm 750 mm ...
R SeriesAnalog Temposonics
Data Sheet R-Series Analog Temposonics® RP and RH Strokelength50…7600mm • Rugged industrial sensor • Linear and absolute measurement • LEDs for sensor diagnostics • Non-contact sensing with highest durability • Superior accuracy: Linearity better 0.01 % F.S. • Repeatability 0.001 % F.S. • Direct analog output, position + speed
BA6012-1 - Amphenol Antenna Solutions
Omnidirectional Fiberglass Antenna, 449-471, 2.1dBi, N Female
GTE Analog Data sheet - Temposonics
2 Temposonics® TE Analog ATE EC CEC Data Sheet 5 3 1 2 4 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (waveguide)
Industrial Breakaway Connectors: Enhancing Safety and Efficiency
Industrial breakaway connectors, or friction fit connectors, are essential components in various industries. They ensure the safe and efficient operation of machinery and equipment.
Amphenol Corporation - Financials - SEC Filings
Filter filing type: ...
R-Series RP CANbus 551780 - Temposonics
Data Sheet TECHNICAL DATA Output Interface CAN fieldbus system according to ISO 11898 Data protocol CANopen: CIA standard DS301 V3.0/Encoder profile DS 406 V3.1; CANbasic: CAN 2.0 A Baud rate Transfer rate 1000 kBit/s 800 kBit/s 500 kBit/s 250 kBit/s 125 kBit/s 50 kBit/s 20 kBit/s Cable length < 25 m < 50 m < 100 m < 250 m < 500 m < 1000 m < 2500 m
E-Series ER Product Data Sheet, 550996 Rev E - Temposonics
RS-422 interface. The data format is serial, 4800 Baud, 8-bit data length. Please contact the factory for additional parameter upload protocol details. MTS Sensors Temposonics® Linear-Position Sensors - Product Data Sheet 3 E-Series, Model ER, Document Part No.: 550996, Revision E 02/11, 07/11, 04/13
Data Sheet Addition E-Series – EH with Cable Output - Temposonics
The following technical specifications replace – respectively are an addition to – the data in document EH Analog 551247, EH Start/Stop 551684, EH CANopen 551296 and EH SSI 551297 E-Series – EH with Cable Output Magnetostrictive Linear Position Sensors Data Sheet Addition
BA1012-1 - Amphenol Antenna Solutions
Omnidirectional Fiberglass Antenna, 144-162, 2.1dBi, N Female
Data Sheet *%ZLWKWKUHDGHG DQJH$QDORJ - Temposonics
Data Sheet GB-M/GB-T SENSOR Robust, non-contact and wear free, the Temposonics linear position sensors provide the best durability and accurate position measure-ment solutions in harsh industrial environments. The high quality of the in-house manufactured waveguide forms the basis for precise measurements. The position magnet is mounted on the ...