Search Results for linux date get timezone
Datenblatt E-Serie EP/EL Analog (Dokumentennummer 551245)
I 2 I Temposonics® E-Serie EP/EL Analog Datenblatt 4 5 3 1 Messzyklus 1 Ein Stromimpuls erzeugt ein Magnetfeld 2 Die Interaktion mit dem Magnetfeld des Positionsmagneten generiert einen Torsionsimpuls 3 Der Torsionsimpuls breitet sich aus 4 Der Wandler erfasst die akustische Welle 5 Die Position wird anhand der Laufzeit ermittelt Magnetostriktives Messelement
Kaye Feedthru Fitting for Thermocouples
The Kaye Thermocouple Feedthrough provides easy access for thermocouples through the validation port on steam sterilizers, freeze dryers, or any other closed chamber/container that needs to be validated.
c:userspdf3fa1-nxsj-c01e0 - amphenolrf.com
Title: c:userspdf3fa1-nxsj-c01e0.ps Created Date: 8/14/2014 10:24:36 AM
Assembly Instructions-C34 Amphenol TNC
309 Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com Assembly CLAMP TYPES nut washer gasket clamp male bushing plug body
Model 621C40 | PCB Piezotronics
Model 621C40:High freq ceramic shear ICP® accelerometer, 10 mV/g, 1.6 to 30k Hz, SS case, top exit, 5-44 connector, frequency sweep ISO 17025 acc cal
ZTP-135H Thermopile IR Sensor - amphenol-sensors.com
• Fast response time • Low cost Amphenol Advanced Sensors. Parameter Limits Units Condition Min Typ Max Chip Size 1.8 x 1.8 mm2 Diaphragm Size 1.4 x 1.4 mm2 Active Area 0.7 x 0.7 mm2 Internal Resistance 42 60 78 kW 25°C Resistance T.C 0.12 %/°C ... Created Date: 3/21/2014 8:29:12 AM ...
Autoclave Temperature Mapping | Temperature Validation System - KAYE
Discover the Kaye Validator AVS, a temperature validation system designed for accurate autoclave temperature mapping, ensuring regulatory compliance and process safety. Achieve reliable results with our leading solutions.
Manuale operativo Level Plus - temposonics.com
Level Plus ® Tank SLAER ® Manuale operativo I 5 I N NEMA Type 4X Prodotto Enclosure (custodia) sviluppato per impieghi all'interno e all'esterno, soprattutto per fornire una protezione contro corrosione, sporco e polvere portati dal vento, spruzzi e getti d'acqua ai tubi
PL-700SM-N SERIES Shell Auto-Coupling 27 pole capacity circular ...
STANDARD HOUSINGOPTIONS. PL-700SM-N SERIES. Plastic . Shell Auto-Coupling . Connectors . 27 pole . capacity circular shell connectors. TABLEB: STANDARD PART NUMBERS
600 Amp DC Current transducer with cable - Gemeco
Features From the factory, the DCM100 is configured to use a 200A Hall effect current sensor. If you are using a 400A or 600A current sensor, you should configure the DCM100 for the proper sensor
8655GMES3C11KLF | D-subminiature | Amphenol
Amphenol is one of the leading manufacturers of Input Output Connectors. Contact us today for more details of D-Subminiature, part number 8655GMES3C11KLF
RFS RADIAFLEX® CABLES Installation Guideline - RFS Technologies
For easier installation and in order to get the highest possible quality of installation we recommend going for our Universal Trimming Tools (TRIM-SET-***-***) in addition. For easier and safe installation of grounding kits and for the dismantling of cable jacket for the connector
Revolutionary Fiber Management: LiNC® Panel - Blog - amphenol-ns.com
This means fewer truck rolls and less engineering time to determine exact trunk lengths, and less lead time waiting for custom length cable assemblies. And because you only pay out what you need, the problem of storing slack fiber is now a thing of the past. One of the significant advantages of the LiNC panel is its efficient cable utilization.
SGX-7ETO Datasheet - SGX Sensortech
sensor’s life time. 7.) The device is designed to be RoHS compliant. 8.) Poisoning - sensors are designed to operate in a wide range of harsh environments and conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during ... Created Date: 3/31/2020 12:28:02 PM ...
NTC Type NDL Thermometrics Epoxy-Coated Chip Thermistor
R25 W Material System B Value 25/85°C K Maximum Operating Temperature °F (°C) Code R25°C ± 1% Code R25°C ± 2% Code R25°C ± 3% Code R25°C ± 5%
Thermometrics Coolant Temperature Sensor CTS - Amphenol
• Response Time: 5 seconds from 25°C to 85°C in water • Installation Torque: 5.0 N-m ~ 9.5 N-m • Connector: USCAR 3140x-2110 USCAR 064 SEALED (Designed IP67 Compliant) • RoHS Compliant (Directive 2002/95/EC) AAS-930-199A 04/2018 ... Created Date: 6/19/2017 3:35:11 PM ...
ExpressPort SFP+ - Amphenol CS
www.amphenol-icc.com Amphenol Information Communications and Commercial Products Amphenol ICC’s ExpressPort® SFP+ interconnect system provides data transfer speeds of up to 16Gb/s. The design of the ExpressPort ® SFP+ connector minimizes impedance discontinuities and reflections at high data rates and
R SeriesAnalog Temposonics
- Update time 0.5 ms up to 1200 mm / 1.0 ms up to 2400 mm / 2.0 ms up to 4800 mm / 5.0 ms up to 7600 mm stroke length - Ripple < 0.01 % F.S. Velocity measurement: - Range 0.025 - 10 m/s - Deviation < 0.5 % - Resolution 0.1 mm/s Option 0.01 mm/s - Update time (ms) see position measurement Temperature coefficient < 30 ppm/°C Operating conditions
RLKX114-50JFLAB - 1-1/4' RADIAFLEX® Radiating Cable, only cable in the ...
RLKX114-50JFLAB REV : G REV DATE : 30 Sep 2024 www.rfstechnologies.com All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering Page 1 of 4. MECHANICAL SPECIFICATIONS Jacket JFL, EN50575:2014 + A1:2016 classified cable
CCGX Wi-Fi Module Long Range (Asus USB-N14) - Gemeco
This high power ASUS USB-N14 Wi-Fi adapter (which replaces the previous WNP-UA-002, WNP-UA-002) will give much better reception at long range when connecting a Victron Venus GX or Color Control GX to a wireless network.