Search Results for lorentz 2000 manual
Downloads - Lutze Inc.
Cable . Control Cables, Electronic Cables, Actuator Sensor Cables, Bus and Network Cables, Motor, VFD, Servo and Feedback Cables
DST800L Smart™ Sensor Bronze Thru-hull NMEA 2000® - Airmar
The DST800L is a Smart ™ Triducer ® Multisensor that offers depth, speed, and temperature functions in one thru-hull fitting. The long-stemmed transducer is designed for use in thick-hulled, wooden boats or vessels with a steep deadrise. The optional high-performance fairing vertically orients the beam for strong return echoes, resulting in optimal performance even at higher speeds.
Model 699A06 Portable Vibration Calibrator Installation and ... - PCB
Model 699A06 Portable Vibration Calibrator Installation and ... - PCB
CAL200 Tech Reference Manual - PCB
2-4 Microphone Calibration CAL200 Manual Step 5 Make a reading. If the reading is not within tolerance, refer to the instrument’s manual for instructions on how to adjust the instrument. Step 6 Check the ambient noise level to insure that the calibration was not influenced by noise from external sources. The CAL200 needs to be on the ...
ITC-Series Inverter/Charger System - charlesindustries.com
Owner’s Manual ITC-Series Inverter Page 1 Owner’s Manual 8/07/03 ITC-Series Inverter/Charger System Model ITC12-2100 and 3200 Vanner Incorporated 4282 Reynolds Drive Hilliard, Ohio 43026 (614) 771-2718 1-800-ACPOWER www.vanner.com Owner’s Manual D911149 August 18,2003 File D911149-A.doc
Calibrator Technical Reference - PCB
1-4 Microphone Calibration CAL250 Manual Step 4 Press the CAL250 ON button. With a fresh battery, the calibrator will issue a tone for more than 60 seconds before automatically shutting off (see note below). Step 5 Make a reading. If the reading is not within tolerance, refer to the instrument’s manual for instructions on how to adjust the ...
Autoclave Temperature Mapping | Temperature Validation System - KAYE
Advanced Validation Technology. The Kaye Validator AVS (Advanced Validation System) is an all-in-one temperature mapping and thermal validation system that combines precise sensor measurements with all GxP requirements for calibration and traceability to national standards, while generating compliant reports and managing the validated assets and validation equipment.
Operation Manual R-Series V EtherCAT 552059 - temposonics.com
Temposonics® R-Series V EtherCAT® Operation anual I 6 I 3. Identification a Sensor model R P 5 Profi le b Design G Magnet slider backlash free (part no. 253 421), suitable for internal linearization L Block magnet L (part no. 403 448) M U-magnet OD33 (part no. 251 416-2), suitable for internal linearization
Model 4107-01A Rotary Transformer Torque Sensor Installation and ... - PCB
Torsional Stiffness 17,700 kin-lb/radian 2000 kN-m/radian Rotating Inertia 0.152 in-lb-sec 20.017 N-m-sec Maximum Speed 6000 RPM 6000 RPM All specifications are at room temperature unless otherwise specified. In the interest of constant product improvement, we reserve the right to change specifications without notice.
Model 059740-01185 Fastener Torque-Tension Load Cell, Clamp Load ... - PCB
FTA9000 FASTENER TORQUE-TENSION LOAD CELL OPERATION MANUAL 2 1.0 INTRODUCTION Fastener torque-tension load cells manufactured by PCB Load & Torque are designed to accurately measure tensile loads and ... 059650-01604 135k 600k 1,475 2,000 3/4” (M20) 1 1/8” (M30)
Data Sheet R-Series V RP5 Analog - temposonics.com
Vibration test 30 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies) EMC test Electromagnetic emission according to EN 61000-6-3 Electromagnetic immunity according to EN 61000-6-2 The RP5 sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 No. 1091 and TR CU 020/2011
Data Sheet E-Series ER Analog - temposonics.com
Vibration test 5 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies) EMC test Electromagnetic emission according to EN 61000-6-3 Electromagnetic immunity according to EN 61000-6-2 The ER sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 Nr. 1091 and TR ZU 020/2011 Magnet movement velocity ≤ 5 m/s
Data Sheet E-Series EP/EL Analog (Doc Part No. 551245)
Manuals, Software & 3D models available at: www.temposonics.com d Connection type D 3 4 M12 male connector (5 pin) e Operating voltage 1 +24 VDC (−15/+20 %) f Output Voltage V 0 1 0…10 VDC (1 output channel with 1 position magnet) V 1 1 10…0 VDC (1 output channel with 1 position magnet) V 0 2 0…10 VDC (2 output channels with 2 position ...
110WX NMEA 0183 / 2000® WeatherStation® - (No Relative Humidity) - RS422
Home / WeatherStation Instruments / 110WX NMEA 0183 / 2000® WeatherStation® - (No Relative Humidity) - RS422. 110WX NMEA 0183 / 2000® WeatherStation® - (No Relative Humidity) - RS422. Part # WS-110WX. MFG # 44-823-1-01. ... True Wind Speed and Direction: Yes (Manual Alignment to North)
Operation Manual Level Plus CHAMBERED - Temposonics
Level Plus ® CHAMBERED Operation Manual I 3 I 1. Contact information United States General Tel: +1-919-677-0100 Fax: +1-919-677-2343 E-mail: info.us@temposonics.com
Operation Manual R-Series V Profinet 551973 - Temposonics
Temposonics® R-Series V PROFINET IO RT & IRT Operation Manual I 5 I a Sensor model R P 5 Profi le b Design G Magnet slider backlash free (part no. 253 421), suitable for internal linearization L Block magnet L (part no. 403 448) M U-magnet OD33 (part no. 251 416-2), suitable for internal linearization N Magnet slider longer ball-jointed arm (part no. 252 183), ...
Model 5302D-02A PCB L&T TORKDISC® System, 16-bit telemetry system ...
Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com. Manual 21354 Rev E ECN 50523 Repair and Maintenance
Model 039201-53102 PCB L&T Rotary Torque Angle Transducer, w/Auto-ID ...
51678 RS Rotary Torque Transducer Manual_CE.doc 3/12/2012 Rotary Socket Wrench Torque Transducer Installation and Operating Manual For assistance with the operation of this product, contact: RS Technologies Division of PCB Load & Torque, Inc. Toll-Free in USA: 888-684-2894 24-hour SensorLine SM: 716-684-0001 Fax: 248-888-8266
Temposonics
1.1 Purpose and use of this manual The content of this technical documentation and of its various annexes is intended to provide information on mounting, installation and commissioning by qualified automation personnel 1 or instructed service technicians who are familiar with the project planning and dealing with Temposonics® sensors.
Absolute, Non-Contact Position Sensors User’s Manual - Temposonics
User’s Manual M-Series Analogue/PWM Tester Magnetostrictive Linear Position Sensors Temposonics® Absolute, Non-Contact Position Sensors M-Series Analogue/PWM Tester User’s Manual Document Part Number 5 132 Rev is on B