Search Results for nsa8420-9
1695-2180 / 1695-2180 MHz - amphenol-antennas.com
3-Point Mounting Bracket Kit MKS09P02 50-115 mm 2.0-4.5 in 4.1 kg 9 lbs 3-Point Mounting & Downtilt Bracket Kit MKS09T02 50-115 mm 2.0-4.5 in 6.4 kg 14 lbs s
6782-5001-dB - Sheet1 - XMA Corp
marking area see note qty. part number description item no. x 6782-5001-db attenuator, 1.85mm-m/f, dc-65 ghz, 1w 1 ta-6782-5001-dbu assembly,attenuator, 1.85mm-m/f, dc-65
www.pctel.com
We would like to show you a description here but the site won’t allow us.
Amphenol PCD Shenzhen
We would like to show you a description here but the site won’t allow us.
Thermometrics temperature sensor solutions
Global Excellence in Temperature Sensors The Thermometrics temperature product line contributes more than 70 years of technology experience in the
696-960 / 696-960 / 1695-2400 / 1695-2400 MHz - Amphenol Antenna Solutions
2-Point Mounting & Downtilt Bracket Kit 36210006 40-115 mm 1.6-4.5 in 4.1 kg 9.0 lbs s TWIN654CU000 x 696-960 / 696-960 / 1695-2400 / 1695-2400 MHz Twin Dual Band | Oct Port | Panel Antenna | (2x) XX-Pol | 68° / 68° / 65° / 65° | 13.8 / 13.8 / 17.0 / 17.0 dBi | Variable Tilt. Quoted performance parameters are provided to offer typical, peak ...
696-896 / 1695-2180 MHz - Amphenol Antenna Solutions
174 mm [6.9 in] 79.5 mm [3.1 in] Quoted performance parameters are provided to offer typical, peak or range values only and may vary as a result of normal testing, manufacturing and operational conditions. Extreme operational conditions and/or stress on structural supports is beyond our control. Such conditions may result in damage to this product.
6782-6165-dB - Sheet1
4.x" .05" [1.27].xx" .03" [.76].xxx" .010" [.25] angles ±0°30' remove all burrs/sharp w/ break / r of .003" to .0005" unless otherwise noted dias concentric <.003 t ...
Control/Instrumentation Chem-Gard 200 Single Conductor Cable
Wire and Cable otion Control Control/Instrumentation us/Data Igniter Wire Reeling Cable 91 ortable Cord ower Cable Welding Cable Thermocouple RTD Wire
696-960 / 1695-2400 / 1695-2400 MHz - amphenol-antennas.com
Vertical Beamwidth 21.0° 17.5° 9.0° 8.3° 7.6° 7.6° Gain 14.3 dBi 15.3 dBi 17.0 dBi 17.5 dBi 18.0 dBi 18.0 dBi Electrical Downtilt 0-14° 0-10° Impedance 50Ω 50Ω VSWR < 1.5:1 < 1.5:1 Upper Sidelobe Suppression > 16 dB Typical > 18 dB Typical Front-to-Back Ratio > 25 dB > 27 dB In-Band Isolation > 25 dB > 28 dB
1695-2180 / 1695-2180 MHz - Amphenol Antenna Solutions
1695-2180 / 1695-2180 MHz QUAD856W0000x Quoted performance parameters are provided to offer typical or range values only and may vary as a result of normal manufacturing and operational conditions.
696-960 / 1710-2170 MHz - Amphenol Antenna Solutions
Vertical Beamwidth 7.4° 6.9° 7° 6.5° 6° Gain 16.3 dBi 16.8 dBi 16.4 dBi 17.0 dBi 17.3 dBi Electrical Downtilt 0-10° 0-10° Impedance 50Ω 50Ω VSWR < 1.5:1 < 1.5:1 Upper Sidelobe Suppression > 18 dB Typical > 17 dB Typical Front-to-Back Ratio > 25 dB > 25 dB In-Band Isolation > 25 dB > 30 dB Isolation Between Ports > 30 dB > 30 dB
TRIAXIAL DC RESPONSE ACCELEROMETER - pcb.com
Magnetic Sensitivity 40 equiv. µg/gauss 3.9 (m/s²)/Tesla [2] Electrical Excitation Voltage 5 to 32 VDC 5 to 32 VDC Current Consumption ≤ 15 mA ≤ 15 mA Output Impedance ≤ 120 Ohm ≤ 120 Ohm Offset Voltage(0 g) ± 20 mVDC ± 20 mVDC [6] Common Mode Voltage(+/- 0.1 VDC) 1.65 VDC 1.65 VDC
Protimeter Digital Mini Pin Type Moisture Meter
Dry (green): 6-16.9% At Risk (yellow): 17-19.9 Wet (red): 20-99.9 Display 1 Digital LCD backlit Display 2 Multicolor LED arc - Green(dry), Yellow (at risk) and Red (wet) Depth of moisture Pin up to 0.4 in (10mm) Case Pouch with belt loop Protimeter’s patented Reference Mode is particularly useful when there is a need to compare measurements
696-960 / 1695-2180 MHz - Amphenol Antenna Solutions
Vertical Beamwidth 9.2° 7.9° 6.0° 5.5° 5.0° Gain 15.1 dBi 15.8 dBi 16.7 dBi 16.9 dBi 17.2 dBi Electrical Downtilt 0-10° 0-10° Impedance 50Ω 50Ω VSWR < 1.5:1 < 1.5:1 Upper Sidelobe Suppression > 18 dB Typical > 18 dB Typical Front-to-Back Ratio > 30 dB > 30 dB In-Band Isolation > 23 dB > 25 dB Isolation Between Ports > 30 dB > 30 dB
CTOS-CTOL-debords.qxd (Page 1) - Amphenol-Air LB
9 Example: CTOS F 2 01 Y 2.50 28 X BPF ST2 Small Optical Field Connector Plug terminated Channel number : 1, 2, 4 50 / 125 µm fiber fiber: 01 62,5 / 125 µm fiber fiber: 02 Compatible wavelength 1300 nm: Y Compatible wavelength 840 - 1300 nm: Z Cable length in meter (if L<10 m: x.xx) Cable diameter from 2,8 to 7 mm max (see cable catalog)
TRIAXIAL DC RESPONSE ACCELEROMETER - pcb.com
Magnetic Sensitivity 40 equiv. µg/gauss 3.9 (m/s²)/Tesla [2] Electrical Excitation Voltage 5 to 32 VDC 5 to 32 VDC Current Consumption ≤ 15 mA ≤ 15 mA Output Impedance ≤ 120 Ohm ≤ 120 Ohm Offset Voltage(0 g) ± 20 mVDC ± 20 mVDC [6] Common Mode Voltage(+/- 0.1 VDC) 1.65 VDC 1.65 VDC
Explosion-proof, acceleration loop powered sensor
Wilcoxon Sensing Technologies 8435 Progress Drive Frederick, MD 2101 SA An Amphenol Company ote e to continos process improement, specifications are sect to cane itot notice.
TRIAXIAL DC RESPONSE ACCELEROMETER - pcb.com
Magnetic Sensitivity 40 equiv. µg/gauss 3.9 (m/s²)/Tesla [2] Electrical Excitation Voltage 5 to 32 VDC 5 to 32 VDC Current Consumption ≤ 15 mA ≤ 15 mA Output Impedance ≤ 120 Ohm ≤ 120 Ohm Offset Voltage(0 g) ± 20 mVDC ± 20 mVDC [6] Common Mode Voltage(+/- 0.1 VDC) 1.65 VDC 1.65 VDC
TRIAXIAL DC RESPONSE ACCELEROMETER - pcb.com
Magnetic Sensitivity 40 equiv. µg/gauss 3.9 (m/s²)/Tesla [2] Electrical Excitation Voltage 5 to 32 VDC 5 to 32 VDC Current Consumption ≤ 15 mA ≤ 15 mA Output Impedance ≤ 120 Ohm ≤ 120 Ohm Offset Voltage(0 g) ± 20 mVDC ± 20 mVDC [6] Common Mode Voltage(+/- 0.1 VDC) 1.65 VDC 1.65 VDC