Data Sheet R-Series V RP5 Profinet 551961 - Temposonics
Vibration test 30 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies) EMC test Electromagnetic emission according to EN 61000-6-3 Electromagnetic immunity according to EN 61000-6-2 The sensor meets the requirements of the EC directives and is marked with ... 18° (1.65) (0.55) M5 24 (0.94) ...
44Series - Amphenol Sine
10° 20° 30° 40° 50° 60° 70° 80° 90° 100° 110° 120° ... 3 Position 8 lbf 18 lbf 4 Position 9 lbf 20 lbf 5 Position 10 lbf 30 lbf 6 Position 10 lbf 30 lbf Updated 03-2024 2 of 4. www.amphenol-sine.com www.amphenol-sine.com 44 Series™ - Cut-Away View A Plug Housing B Receptacle Housing
Coaxial Cable Guide - Amphenol RF
Amphenol RF offers a broad range of connectors designed to terminate to many commercially available coaxial cable types. The following cable guide lists standard flexible, Low Loss, semi-rigid and conformable, micro-coaxial, and corrugated cable as well as associated product links.
amphe-lite-subminiature-connectors-catalog-amphenol-industrial
15-18 I 18 18 15-19 I 19 19 15-35 M 37 37 15-97 I 12 8 4 15-AC M 26 24 2 17-2 M 39 38 1 17-6 I 6 6 17-8★ II 8 17-22★ NA 4 2 2 17-26 I 26 26 17-31 M 19 4 11 4 ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ connectors. *
Telaire T3030 CO2 Sensors for Harsh Environments with Analog Input
Telaire T3030 CO2 Sensors for Harsh Environments with Analog Input
IECEx - PCB
conditioner or data acquisition system that includes 18 to 30 VDC and 2 to 20 mA of constant current. IECEx IECEx. IECEx IECEx. Models 352A71 & 352A72 Model 352A73. Model 352A74. P. roducts Shown at Actual Size. 3425 Walden Avenue, Depew, NY 14043 USA. pcb.com | [email protected] | 800 828 8840 | +1 716 684 0001
97 series | Amphenol Global Search | Amphenol
Search Results for 62 in 16 inmeta:gsaentity_divisions=amphenol%20tuchel 62IN - Amphenol In Amphenol 62IN series connectors are general purpose, environment resistant , miniature circular connectors with three- ... 18-11 62 119 241 340 20-41 45 126 225 - 22-21 16 135 175 349 22-55 30 142 226 314 20-29 63 144 252 333 I nsert Orientations 60 155 ...
Piezovelocity transducers - Wilcoxon Sensing Technologies
18 - 30 VDC 2 - 10 mA 18 - 30 VDC 2 - 10 mA Electrical noise, equiv. in/sec, nominal: Broadband 2.5 Hz to 25 kHz Spectral 10 Hz 100 Hz 1,000 Hz 100 µin/sec 10 µin/sec/√Hz 1.0 µin/sec/√Hz 0.2 µin/sec/√Hz 40 µin/sec 4.0 µin/sec/√Hz 0.4 µin/sec/√Hz 0.05 µin/sec/√Hz ...
Amphenol
RECEPT, 18 SZ, 20 PIN, STD ARRANGEMENT, NORMAL SEAL, SRA,DURAMATE AHDP SERIES 44724 Morley Drive Clinton Township, MI 48036 Sine Systems - www.amphenol-sine.com Amphenol ... All dimensions are in metric(mm). 2) Tolerances are as follows: 1 PL DEC ±0.30 2 PL DEC ±0.15 QUANTITY SIGNATURES Fractions ±1/64
Amphenol
AMPHENOL CORPORATION Amphenol Industrial Phone: 888-364-9011 20 Valley Street Endicott, NY 13760-3600 www.amphenol-industrial.com Amphenol®. 97 Series Connectors are UL recognized and CSA recognized.
Amphenol
AMPHENOL CORPORATION Amphenol Industrial Phone: 888-364-9011 20 Valley Street Endicott, NY 13760-3600 www.amphenol-industrial.com Amphenol®. 97 Series Connectors are UL recognized and CSA recognized.
Data Sheet MH-Series MH Analog - Temposonics
3 Temposonics® MH-Series MH Analog Data Sheet */ Resonance frequencies excluded **/ According to calculations under use of the FKM guideline Cycles Ø 7 mm sensor rod Ø 10 mm sensor rod Dynamic pressure: < 2 × 106 pressure cycles 300 bar 350 bar Static pressure: < 2 × 104 pressure cycles 400 bar 450 bar Proof pressure: Maximum 5 minutes testing time for cylinder pressure test 525 bar 625 bar
RFS RADIAFLEX® CABLES Installation Guideline - RFS Technologies
INSTALLATION GUIDELINE www.rfsworld.com RFS RADIAFLEX® CABLES Rev C | 11.2022 7 Cable – Connector connection For easy planning, logistic and maintenance RFS recommend going for female connectors on both ends of
General purpose accelerometer - Wilcoxon Sensing Technologies
Resonance frequency 30 kHz Transverse sensitivity, max 5% of axial Temperature response: –55°C +120°C –20% ... Power requirement: Voltage source Current regulating diode 18 - 30 VDC 2 - 10 mA Electrical noise, equiv. g: Broadband 2.5 Hz to 25 kHz Spectral 10 Hz 100 Hz 1,000 Hz 700 µg 10 µg/√Hz 5 µg/√Hz 5 µg/√Hz
MIL-DTL-38999 Series III - TV Connectors - Amphenol Aerospace
Amphenol® Tri-Start connectors provide EMI/EMP shielding capability which exceeds MIL-DTL-38999 Series III requirements. The TV and CTV Series III connector with standard solid metal-to-metal coupling, EMI grounding fingers and conductive finishes have proven to be the ultimate in EMI/EMP shielding effectiveness.
Amphenol Pcd
an 8 indent crimp configuration and will crimp wire sizes 18 AWG (1.0mm2) through 32 AWG (0.3mm2) To crimp wire size 18 AWG (1.0mm2), order contact positioner K13-1. To crimp wire size AWG (0.5mm2 ) through 30 AWG (0.05mm2) order contact positioner K-13-1. Each positioner is equipped with a data plate which gives the correct crimp-depth setting for
MIL-DTL-83723, Series III, Pyle B - Amphenol Aerospace
83723 III 20 Contact Amphenol Aerospace for more information at 800-678-0141 • www .amphenol-aerospace .com Pyle B MIL-DTL-83723, Series III, Pyle ® Sq. Flange Receptacle, Threaded - Quick Reference SQUARE FLANGE RECEPTACLE THREADED Military: M83723/82 with Sockets, Classes G, K
INDUSTRIAL ICP® VELOCITY SENSOR - PCB
Settling Time(within 1% of bias) ≤ 30 sec ≤ 30 sec Excitation Voltage 18 to 28 VDC 18 to 28 VDC Constant Current Excitation 2 to 10 mA 2 to 10 mA Output Impedance < 100 Ohm < 100 Ohm Output Bias Voltage 8 to 12 VDC 8 to 12 VDC Spectral Noise(10 Hz) 25 µin/sec/√Hz 0.64 µm/sec/√Hz [6]
109322-07 | Amphenol Global Search | Amphenol
Description. DESIGNED FOR USE IN 100GB/S DATA RATE LINKS. COMPLIANT WITH THE SFF-8636, IEEE802.3BM OR ITU-T G959.1. Amphenol's 100G QSFP28 optical modules include SR4, AOC, AOC break out, CWDM4, LR4, ER4 Lite, ER4 and ZR4 series, which adopt LC or MPO optical ports and are compatible with IEEE802.3bm, SFF-8636 and other standards; With low ...
RELEASED DRAWING JAN-18-2014 ARROW TOMMY - Amphenol Sine
B1 - RELEASED DRAWING JAN-18-2014 ARROW MATERIALS LIST SIZE PROCESS SPECIFICATIONS: MATERIAL SPECIFICATIONS: UNLESS OTHERWISE SPECIFIED 3 PL DEC ±0.08 1) All dimensions are in metric(mm). 2) Tolerances are as follows: 1 PL DEC ±0.30 2 PL DEC ±0.15 QUANTITY SIGNATURES Fractions ±1/64 Angles ±1° APPROVAL: ENGINEER: CHECKED: DRAWN: SCALE ...