Search Results for piezo polymer coaxial cable
Model 003C10 | PCB Piezotronics
Model 003C10:Low-noise coaxial cable, blue PTFE jacket, 10-ft, 10-32 coaxial plug to BNC plug . Main Menu. 0 1 1. Total Customer Satisfaction +1 800-828-8840. Search. 0 Customer Cart Request a Quote. Log In. Log In. Need an Account? Start Here ... Piezoelectric ICP® Shock;
Introduction to Piezoelectric Force Sensors - PCB
Standard, two-wire or coaxial cable when flexed, generates an electrostatic charge between the conductors. This is referred to as "triboelectric noise" and cannot be distinguished from the sensor's crystal electrostatic output. "Low noise" cables have a special graphite lubricant between the dielectric shield which minimizes the triboelectric ...
Selecting the Correct High Sensitivity Piezoelectric ... - PCB
Piezoelectric materials produce a high output with very little strain. They have no deflection. This makes piezoelectric sensors rugged and their signal linear over a wide amplitude range. Potentially, an accelerometer can measure acceleration levels as low as 0.0001 g's. Piezoelectric materials can only measure dynamic or changing events.
Vibration sensor wiring and cabling - Wilcoxon Sensing Technologies
Assure that high quality, well-shielded cables are used. If cable splices are made, complete shielding should be maintained. Proper cable routing is also recommended. Avoid routing sensor cables alongside AC power lines; cables should cross AC power lines at right angles. Where possible, provide a separate grounded conduit to enclose the sensor ...
Model 353B04 | PCB Piezotronics
Miniature Piezoelectric; High Temperature; ... General purpose coaxial cable, white FEP... $58.00 USD (Pricing valid only in the U.S.) Add to Cart. Model: 003C10. Low-noise coaxial cable, blue PTFE jacke... $61.50 USD (Pricing valid only in the U.S.) Add to Cart. Model: 485B39.
Cable Configurator | PCB Piezotronics
Add or remove components to create custom cables. Main Menu. 0 1 1. Total Customer Satisfaction +1 800-828-8840. Search. 0 Customer ... Piezoelectric ICP® Shock; ... Cables. General Purpose Coaxial; Low Noise Coaxial; 4-Conductor; Multi-conductor Cables; Low Outgassing Cables; Cable Test Box;
Sensors for Condition Monitoring | PCB Piezotronics
We offer a full line of piezoelectric accelerometers, velocity sensors, dual output vibration sensors, 4-20 mA vibration transmitters, switches, relays, cables, displays and accessories. Virtually all of our products are certified for use in hazardous areas through CSA and ATEX.
Introduction to Piezoelectric Industrial Accelerometers - PCB
The piezoelectric sensing element and seismic mass are secured to a center post/base standing upright via a retaining ring as shown in figure 3. This preload produces a stiff structure with good frequency response and greater mechanical integrity. ... Often times coaxial cables are used since only two wires are needed and coaxial cables are ...
Cause of and Solution for Cable Generated Noise in MEMS ... - PCB
securing the cable to any structure in such a manner that stress waves couple into it (keep it as free as possible), and (3) use as much graphite as possible as a cable filler between cable constituents. Testing was performed to evaluate these solutions postulates. Figure 8 shows three cables affixed to a long, slender bar with aluminum tape. The
Model 352C04 | PCB Piezotronics
Miniature Piezoelectric; High Temperature; ... General purpose coaxial cable, white FEP... $58.00 USD (Pricing valid only in the U.S.) Add to Cart. Model: 003C10. Low-noise coaxial cable, blue PTFE jacke... $61.50 USD (Pricing valid only in the U.S.) Add to Cart. Model: 485B39.
Model 034W20 | PCB Piezotronics
Piezoelectric ICP® Shock; ... lightweight FEP cable, 20-ft, 1/4-28 4-socket plug, IP68 rated to triple splice assembly with (3) 1-ft coaxial cables each with a BNC plug (AC) Cable assembly consists of the following components: Model 034 cabling Model RB connector Model JW connector. Specification Notes.
ow noise coaxial cable assembly - PCB
The 3090CM12 coaxial cable assembly is a high reliability cable designed for use with charge-mode . piezoelectric accelerometers. The cable enjoys a long history of reliable use spanning from laboratory use to flight-testing. The raw cable, 10-32 connector and pin assemblies are made in-house to ensure the highest quality
TN-17 Accelerometer Selection Considerations - PCB
Cable and Connectors-PE accelerometers require the use of high insulation resistance, low-noise, coaxial cable. Low-noise cable has a graphite lubricant embedded in the dielectric layer to minimize friction and generation of "triboelectric" static electricity. The electrostatic charge generated by cable motion is the same as
Model 352C03 | PCB Piezotronics
Miniature Piezoelectric; High Temperature; ... General purpose coaxial cable, white FEP... $58.00 USD (Pricing valid only in the U.S.) Add to Cart. Model: 003C10. Low-noise coaxial cable, blue PTFE jacke... $61.50 USD (Pricing valid only in the U.S.) Add to Cart. Model: 485B39.
Introduction to Piezoelectric Accelerometers - PCB
An ICP ® accelerometer is a sensor that generates an electrical output proportional to applied acceleration. ICP ® accelerometers are designed to measure vibration and shock for a wide variety of applications. They are simple to use and accurate over a wide frequency range which makes them the recommended choice for many testing situations. ICP ® is a PCB ® registered trademark that stands ...
Model 352A21 | PCB Piezotronics
Piezoelectric ICP® Shock; ... Miniature, low-noise, blue coaxial cable, 10-ft, 3-56 plug to 10-32 plug: 1: 039A27: Removal tool (for Models 352A21, 352C22, 357A09, 357C10 & 352A25) 1: 080A109: Petro Wax, one square, 1" x 1" x 0.25" 1: ACS-1: Single axis amplitude response calibration from 10 Hz to upper 5% frequency, NIST traceable: 1:
Model 113B26 | PCB Piezotronics
Piezoelectric ICP® Shock; ... Cables. General Purpose Coaxial; Low Noise Coaxial; 4-Conductor; Multi-conductor Cables; Low Outgassing Cables; Cable Test Box; ... Electrical Connector: 10-32 Coaxial Jack; Weight: 0.20 oz (6.0 gm) Specification Notes [1] Zero-based, least-squares, straight line method. ...
Low Outgassing Accelerometers and Cables - PCB
contamination contributors. Some examples of cables, shown below in Figure 7, use materials such as Viton® and Teflon®, which are known to have low TML and CVCM values. Series 030EXPH Mini-coax Cable Series 034 Triaxial Breakout Cable Figure 7 Low Outgassing Cable Examples 27th Aerospace Testing Seminar, October 2012 5
Signal Conditioning Basics | PCB Piezotronics
Certain piezoelectric sensors exhibit exceptionally high values of internal source capacitance and can be plugged directly into high impedance (>1 Megohm) readout devices such as oscilloscopes and analyzers. ... Furthermore, the high-impedance output signal makes the use of low-noise coaxial cable mandatory and precludes the use of such systems ...
PIEZOELECTRIC FORCE RINGS - PCB
Charge systems rely on low noise cables and a high insulation resistance cable to avoid signal degredation over long cable . lengths or in areas with environmental contamination (fluids, particulate, or electrical noise). Charge amplified systems excel PCB offers charge output models (without ICP ®