Search Results for pl082-300
cable connector r/a T 3XXX 055 U - amphenol-sine.com
300 V (63 V) 100 V (32 V) 150 V V) Rated voltage UL 1977 250V 60V Rated impulse withstand voltage2) IEC 60664-1 1500 V (1500 V) 1200 V (800 V) 1500 V (1500 V) 1200 V V) Pollution degree2) IEC 60664-1 1 (2) Installation category IEC 60664-1 I Insulation group IEC 60664-1 II, 400 < CTI < 600 Current rating IEC 60512-5-2
VQ23TB Combustible Gas Detector Elements - SGX Sensortech
0 50 100 150 200 250 300 350 400 . MINUTES . SGX Sensortech(IS) Ltd Registered in England No.08067077 . A1A-VQ23TB Issue 1,15 June 2015. OUTLINE (All dimensions without limits are nominal) Ref Millimetres Inches A 11.3 max 0.445 max 10.8 min 0.425 min B 6.35 max 0.250 max 5.85 min 0.230 min C 3.69 max 0.145 max 3.43 min 0.135 min D 40.0 min 1. ...
DA T 3XXX 551 U - Amphenol Sine
300 V (63 V) 100 V (32 V) 150 V (32 V) Rated voltage UL 1977 250 V 60 V Rated impulse withstand voltage2) IEC 60664-1 1500 V (1500 V) 1200 V (800 V) 1500 V V) 1200 V (800 V) Pollution degree2) IEC 60664-1 1 (2) Installation category IEC 60664-1 I Insulation group IEC 60664-1 II, 400 < CTI < 600 Current rating IEC 60512-5-2
Thermometrics GE-1711/GE-1797 Engine Temp. Sensor
Apply potential difference of 300 VDC between the sensor leads & housing, max allowable leakage current is 40μA Four Temperature Parametric Verify resistance at -40, 25, 125, and 180°C Thermal Time Constant Must take less than 4 seconds for thermistor to reach 63.2% of the temperature difference between 25°C and 65°C in water Wire Pull Force
Home - Amphenol Australia
Home - Amphenol Australia
NovaSensor P1301 Low Pressure Silicon Pressure Sensor
Full Scale Output (FSO) 140 to 300 mv 2.5,5psi Linearity (5psi) ±0.25 %FSO 2 Linearity (1,2.5psi) ±0.5 %FSO 2 Pressure Hysteresis ±0.1 %FSO Temperature Coefficient of Zero ±30 µV/V/°C 3 Temperature Coefficient of Resistance 0.36 %/°C 3 Temperature Coefficient of Sensitivity-0.21 %FSO/°C 3 Thermal Hysteresis of Zero 0.25 %FSO 3,7
CA T 3XXX 150 U - amphenol-sine.com
300 V (63 V) 100 V (32 V) 150 V (32 V) Rated voltage UL 1977 250V 60V Rated impulse withstand voltage2) IEC 60664-1 1500 V (1500 V) 1200 V (800 V) 1500 V (1500 V) 1200 V (800 Pollution degree2) IEC 60664-1 1 (2) Installation category IEC 60664-1 I Insulation group IEC 60664-1 II, 400 < CTI < 600 Current rating IEC 60512-5-2
T 3XXX 550 U - Amphenol Sine
300 V (63 V) 100 V (32 V) 150 V (32 Rated voltage UL 1977 250V 60V Rated impulse withstand voltage2) IEC 60664-1 1500 V (1500 V) 1200 V (800 V) 1500 V (1500 V) 1200 V V) Pollution degree2) IEC 60664-1 1 (2) Installation category IEC 60664-1 I Insulation group IEC 60664-1 II, 400 < CTI < 600 Current rating IEC 60512-5-2
Dipole Arrays S.M2-445 - AMPHENOL PROCOM
RF Cavity Combiners by Amphenol Procom for Tx 150-300 W radio systems in 60-500 MHz. Standard products are 2 to 8 channels. Read more here. Explore all Cavity Combiners. Whip Antennas. Amphenol Procom offers a comprehensive collection of quality Whip Antennas for nondirectional communication. See our product line here.
cable connector HA T 3XXX - Amphenol Sine
300 V (63 V) 100 V (32 V) 150 V V) 60 V (32 V) Rated voltage UL 1977 250V 60V Rated impulse withstand voltage2) IEC 60664-1 1500 V (1500 V) 1200 V (800 1500 V V) 1200 V (800 V) Pollution degree2) IEC 60664-1 1 (2) Installation category IEC 60664-1 I Insulation group IEC 60664-1 II, 400 < CTI < 600 Current rating IEC 60512-5-2
Thermometrics GE-1711/GE-1797 Engine Temp. Sensor
Apply potential difference of 300 VDC between the sensor leads & housing, max allowable leakage current is 40μA Four Temperature Parametric Verify resistance at -40, 25, 125, and 180°C Thermal Time Constant Must take less than 4 seconds for thermistor to reach 63.2% of the temperature difference between 25°C and 65°C in water Wire Pull Force
cable connector HA T 3XXX 004+024+048 U - Amphenol Sine
300 V (63 V) 100 V (32 V) 150 V V) 60 V (32 V) Rated voltage UL 1977 250V 60V Rated impulse withstand voltage2) IEC 60664-1 1500 V (1500 V) 1200 V (800 V) 1500 V (1500 V) 1200 V (800 V) Pollution degree2) IEC 60664-1 1 (2) Installation category IEC 60664-1 I Insulation group IEC 60664-1 II, 400 < CTI < 600 Current rating IEC 60512-5-2