Search Results for planilhas guardar dinheiro em 1 ano
Voltage Compensated, Media Isolated, High Pressure Sensors
1. Performance with offset , thermal accuracy of offset and thermal accuracy of FSO compensation resistors. 2. FSO with 10 VDC. 3. Linearity by best fit straight line. 4. 32°F to 158°F (0°C to 70°C) with reference to 77°F (25°C). 5. 32°F to 158°F (0°C to 70°C), by design.
Assembly Instruction for BEDIA LEVEL MONITORING SENSORS
Created: 09.04.2013 Version: 1.1 General Description BEDIA sensors, type CLS, are installed in engines, commercial vehicles, ships, power engines, etc. to monitor the fill level of aqueous and oily liquids. For engines these are used to monitor the levels of cooling water, oil and fuel for example. The sensors are installed safely for automatic
B A1 - Amphenol Sine
A Series™ - Contact Size 16 Options (Works with: AT, ATV, AHD-9, ARC, DuraMate and PanelMate Series) Amphenol Sine Systems 44724 Morley Drive, Clinton Township, MI 48036 USA www.amphenol-sine.com 10-2023 Machined Contacts, Sockets & Pins Part Number DescriptionSize AWG Type
Munich, 2024 -02 -29 Head of Certification Body Fred Wenke
em ( DAkkS Deutsche Akkreditierungsstelle D.ZM.14143-01.oo . Author: Krätz, Marianne Created Date: 2/29/2024 9:05:19 AM ...
Fischer Panda Marine-Generatoren
4 Die Fischer Panda Generatoren sind in drei verschiedenen Wicklungsausführungen erhältlich. Diese Wicklung erzeugt elektrische Energie aufgrund der Drehbewegung der rotierende Welle
PRO-HDAR450-3
Model Duplex Filter Freq. Band Pre-selector Rx Freq. Band Duplex filter Bandwidth (BW) and Tx/Rx Spacing Max. input power; PRO-HDAR450-3: Low : 340 - 400 MHz = L
18.0 ± 0 - svmicrowave.com
V S W R : 1.3:1 Max, DC to 18.0 GHz 1.5:1 Max, 18.0 + GHz I N S E R T I O N L O S S : 3.03 dB Max N O T E S 1. See individual data drawings for connector specifications 2. Dimensions shown are in inches TITLE: 2.92mm Straight Male to SMPM Size 12 Socket 18" Cable Assembly for Ø.085 Flexible Coax DWG. NO. MS292-085-S12DSMPM-180 DRAWN 2022-10-17 ...
Protimeter Speedy 2000 Series - amphenol-sensors.com
Moisture testers for soils, sands, powders, aggregates, concrete and masonry PROTIMETER Speedy ®
ZTP-115M Thermopile IR Sensor - amphenol-sensors.com
Outline of Sensor Packaging and Pin Arrangement Temperature Accuracy (Typical)-4-3-2-1 0 1 2 3 4 Te m pe r a t u r e D e v i a t i on ℃ O bject Tem p. : 60℃ 0 20 ...
Telaire CO2 Zone Ventilation Control In Buildings Application Note
1. Is CO 2 a contaminant that must be controlled in buildings? At the concentrations typically measured in buildings (400-2,500 ppm), carbon dioxide is not considered to be a health threatening contaminant. The real value in CO 2 sensing in buildings is to estimate the cfm- per-person ventilation rate in the space. This method of
UNIT: mm - amphenol-fuyang.com
Amphenol Fuyang Tel: +86-519-86520303 www.amphenol-fuyang.com No.6 Fengqi Road, HiTech, District, Wujin, Changzhou, Jiangsu, PRC 213164-
NovaSensor P111 Medium Silicon Pressure Sensor Die
1. 0 KPaA for absolute sensors, 0 KPaG for differential or gage sensors. 2. Best fit straight line. 3. Between 32°F and 158°F (0°C and 70°C). 4. Typical value over one year. 5. All values measured at 77°F (25°C) and 1 mA excitation, unless otherwise noted. Shipping and Handling All wafers are shipped in protective containers. The wafers ...
Psyclone™ Protimeter Thermo-Hygrometer Operating Manual
Figure 1 below shows the Psyclone control buttons, while Table 1 on the next page lists the available parameters. Figure 1: The Psyclone (#BLD7800) Control Buttons On/Hold/Off Hold for 2 sec to enter Setup. Protimeter Psyclone Page 1 Table 1: Psyclone Measurement Parameters Parameter Symbol % Relative Humidity % RH
ZTP-115 Thermopile IR Sensor - amphenol-sensors.com
Chip Size 1.8 x 1.8 mm2 Diaphragm Size 1.4 x 1.4 mm2 Active Area 0.7 x 0.7 mm2 Internal Resistance 42 60 78 kW 25°C Resistance T.C 0.12 %/°C Responsivity 42 60 78 V/W 500K, 1 Hz Responsivity T.C -0.10 %/°C Noise Voltage 32 nV rms R.M.S., 25°C NEP 0.53 nW/Hz1/2 500K, 1 Hz Detectivity 1.30 E08 cmHz1/2/W 500K, 1 Hz Time Constant 25 ms ...
High Performance Thermal Circuit Breaker 482-
1 lock washer DIN 137-B4, fitted 6 lock washer DIN 137-B4, bulk shipped UAuxiliary contact S0 without auxiliary contacts S1 with auxiliary contact (NC) Current ratings 0.1...50 A 482 - G 1 1 1 - K1 M1 - A 1 S1 - 10 A ordering example Voltage rating AC 115 V (400 Hz); DC 28 V AC 230 (50/60 Hz) to special order
Multimedia 2016 17 - el-cab.com.pl
709 with 1x MiniDIN, 1x BNC/AMP SM-1-002-04 709 with 2x BNC/AMP SM-1-002-05 2x Camera input // Protection class IP 54 800 x 400 350 cd / m² 12 – 36V-10°C – +65°C 2x MiniDIN / 1 or 2 adapter BNC/AMP (WxHxD) 182 x 120 x 30 mm MONITORS Resolution / TVL Brightness Operating voltage Temperature range Connections Mounting dimensions Resolution ...