Search Results for power blade
Model 601A11 Low-cost Industrial ICP® Accelerometer Installation ... - PCB
All ICP® sensors require a constant current power source for proper operation. A typical sensing system includes an ICP® sensor, ordinary two conductor cable and a basic constant current power supply (as shown in Figure 2). The signal conditioner consists of a well-regulated 18 to 30 VDC source (battery or line-powered), a
Temposonics® R-Series RD4 Position Sensors
Temposonics® RD4 is a high-performance position sensor with detached electronics: the sensor rod with the built-in waveguide is connected via a cable to the electronics. This sensor design allows easy mounting in limited spaces while isolating the sensor electronics from high temperatures, high vibration and shock, or other environmental extremes.
Digital Gauges - SSI Technologies, LLC
Digital Fluid-Trac™ The Digital Fluid-Trac™ drum level Digital Gauge is a cost competitive, non-contact, continuous liquid level drum gauge.
Model 112B11 Charge Output Pressure Sensor Installation and Operating ...
Switch power on and proceed with measurements. Manual Number: 21069 Manual Revision: A ECR Number: 22421 . OPERATION MANUAL FOR ENGINE COMBUSTION SENSORS Modes 112B10 & 112B11 Model 175A01 2 Manual Number: 21069 Manual Revision: A ECR Number: 22421 4.0 CALIBRATION
About | PCB Piezotronics
Company Profile. PCB Piezotronics was founded in 1967 as a manufacturer of piezoelectric quartz sensors, accelerometers, and associated electronics for the measurement of dynamic pressure, force, and vibration.
About - Connor Manufacturing
Established in 1913, Connor Manufacturing, is a US-based company with manufacturing sites located in the USA, Mexico, China, and Malaysia. Connor is a one-stop precision engineering solution provider for your stamped metals and metal fabrication needs.
P79 Traditional/CW In-hull - AIRMAR
600 W of power; Dual-frequency element: 50 kHz with a 45° beamwidth for depth performance to 294 m (1000') 200 kHz with an 12° beamwidth for depth performance to 180 m (600') Adjusts to hull deadrise angles up to 22° Drill-free installation; Recommended for planing-hull powerboats, trailered boats, rigid inflatable boats (RIBS), and racing ...
Temposonics® R-Series V RDV Position Sensors
Discover the new generation of R-Series V RDV high-performance sensors with detached electronics for demanding applications. Space-saving installation thanks to separate electronics, improved level of protection against working process influences. Backwards compatible with RD4 for easy replacement of sensor rod or electronics. Lengths from 25-5080 mm, CE-, UL/CUL-, EAC- and UKCA-certified.
7040165 - AMPHENOL PROCOM
7040165 - AMPHENOL PROCOM
Amphenol
1.3 power contact: copper alloy,tin plated 1.4 shielding: copper alloy, nickle plated 2. specifications: 2.1 current rating: 6.0mm2(mp10b23xx)@35 amps 4.0mm²(sp12a1xx-10)@25 amps 2.5mm²(sp12a1xx)@20 amps "xx" denotes different plating. 2.2 voltage rating: 1000 v ac/dc 2.3 operating temperature: -40°c to +130°c
USB Connectors | Products | Amphenol
Micro USB 2.0 connectors have power contacts of 1.8A and 3A current for fast charging. The plastic tongue and two-layer shells design ensure high reliability and prevent connector damage. Amphenol offers customized designs to suit various customer requirements. These connectors also offer high-speed signal stability of up to 480Mb/s transmission.
Model 3741E1250G DC Response Accelerometer Installation and ... - PCB
require stable power. Unlike standard non -amplified piezoresistive accelerometer designs, this stable power is provided by an internal voltage regulator. Therefore PCB’s high sensitivity DC accelerometers may be supplied with a positive unregulated DC supply voltage, provided it falls within the specified range of the
Introduction to Piezoelectric Accelerometers - PCB
All PCB ® ICP ® accelerometers require power from a constant current DC voltage source. PCB ® offers different types of ICP ® signal conditioners that provide 2 to 20 mA of current at a DC voltage level of +18 to +30 volts. Do not attempt to power ICP ® sensors with commercially available power supplies. The unregulated current will damage and destroy internal electronics.
Amphenol
1.3 power contact: copper alloy, tin plated 1.4 shielding: copper alloy, nickle plated 2. specifications: 2.1 current rating: 6.0mm2(ms10b23xx)@35 amps 4.0mm²(ss12a1xx-10)@25 amps 2.5mm²(ss12a1xx)@20 amps "xx" denotes different plating. 2.2 voltage rating: 1000 v ac/dc 2.3 operating temperature: -40 ℃ to +130
Amphenol Advanced Sensors
Temperature Sensors, Pressure Sensors, CO2 Indoor Air Quality Sensors, Humidity Sensors, Dust Sensors. Advanced sensor technologies and embedded measurement solutions for Automotive, Medical, Industrial, Air Quality Applications.
Backshells Archives - Amphenol PCDAmphenol PCD
Strain relief, environmental protection and EMI/RFI shielding at the termination area of any connector. Support most applications with a full line of Military (MIL) specification, commercial, and custom solutions options.
Design and Selection Criteria of High Temperature Accelerometers - PCB
power generation turbines, gas turbine bearing health monitoring and turbine/compressor sets in oil & gas pipelines. The same sensor might be required to withstand ... Transverse Resonance: The blade pass frequency of a combustion turbine may excite a transverse resonance of the accelerometer. Typically, the transverse resonance of ...
Model 393B31 | PCB Piezotronics
Model 393B31:Seismic, high sensitivity, ceramic flexural ICP® accel., 10 V/g, 0.1 to 200 Hz, 2-pin top conn.
Cable clamps | Amphenol LTD
Fuel Resistant and High Temperature resistant rubbers available; Lightweight, non-corrosive, non-conductive and durable; One-piece design, two-shot moulding with soft fluoro-silicone cushion
Model 625M42 Industrial ICP® Accelerometer Installation and ... - PCB
All ICP® sensors require a constant current power source for proper operation. A typical sensing system includes an ICP® sensor, ordinary two conductor cable and a basic constant current power supply (as shown in Figure 2). The signal conditioner consists of a well-regulated 18 to 30 VDC source (battery or line-powered), a